This classification system database file is accessed by the Autodesk Classification Manager for Revit in order to add classification system values to your Revit elements. This worksheet provides general instructions.
The classification system relies on five (5) distinct worksheet categories: Contacts, Facility, Spaces, Products by Instance, and Products by Type.
"Contact" is referenced by the Autodesk COBie Extension for Revit Contact List, when installed.
"Facility" is referenced by Autodesk COBie Extension for Revit, when installed.
"Space" is referenced by Revit Rooms and Spaces.
"Element" is referenced by model elements.
Each worksheet has a header with information necessary for the Revit Classification Manager. You can edit "Title", "Description", "Version", "Number Parameter", and "Description Parameter". Do not change the "Function" field, or the utility may not function as expected.
"Number Parameter" and "Description Parameter" refer to a Revit parameter in your model. This is where the data from the "Number" column and "Description" column will be stored in your Revit elements. The Parameter must already be created and the name must match exactly with what is typed in the field in the Excel Database. If there are multiple parameters with the same name, the utility has no way to distinguish which one to use. We strongly recommend a parameter with a unique name. These parameters MUST be TEXT parameters in Revit.
You can have multiple worksheets of each category. Feel free to copy the worksheets in this Excel workbook to create new worksheets to use.
You can rename the worksheets to anything that is appropriate for your database. The Classification Manager does not refer to the worksheet names.
In each worksheet, do not edit the first row of data under the table head. This is an automatically generated Title, Description, and Level information based on the fields you fill out in the worksheet header.
The first column is the Classification Number, and should be of a logical structure.
The second column is the Description field.
The third column is the Level column; this column determines where in the "hierarchy" this specific category exists. The Classification Manager will read the classes line by line. If it reads a "3" after a "2", it will place that class as a "child" of the level 2 class. Any level 3 class immediately following will be "siblings" to the original level 3. Once the utility finds another "2", it will end the run of 3's and place that class as a "sibling" to the original level 2.
The fourth column is the Revit Category column. This field can be filled in with a Revit Family Category Code listed below. This will filter the dropdown in the Classification Manager within Revit and include these classes with the Revit family that you identify in this column. The Contacts, Facility, and Spaces worksheets will ignore this field.
3
4
5
6
7
REVIT FAMILY CATEGORY CODES
8
Below is a list of the family category codes in Revit. These are used in classification databases - like the ones included with Revit - to filter classification numbers by family category. These are listed as column D in each of the worksheets (tabs) in this database file. Not every line item needs to be assigned a Revit family category code, but when it is, the filter (in the top right of the dialog box) will only show classification numbers for that particular family category, making it easier to find the pertinent ones.
9
10
DISCIPLINECODEREVIT FAMILY CATEGORY
11
General-2002000Detail Items
12
-2000151Generic Models
13
-2000700Materials
14
-2003000Profiles
15
-2003101Project Information
16
-2001350Specialty Equipment
17
Architecture-2003200Areas
18
-2000127Balusters
19
-2001000Casework
20
-2000038Ceilings
21
-2000100Columns
22
-2000170Curtain Panels
23
-2000340Curtain Systems
24
-2000171Curtain Wall Mullions
25
-2000023Doors
26
-2001370Entourage
27
-2000032Floors
28
-2000080Furniture
29
-2001100Furniture Systems
30
-2003400Mass
31
-2000022Opening
32
-2001263Pads
33
-2001180Parking
34
-2001360Planting
35
-2000126Railings
36
-2000180Ramps
37
-2001220Roads
38
-2000035Roofs
39
-2000160Rooms
40
-2001260Site
41
-2000120Stairs
42
-2001340Topography
43
-2000011Walls
44
-2000014Windows
45
MEP-2008013Air Terminals
46
-2008126Cable Tray Fittings
47
-2008130Cable Trays
48
-2008081Communication Devices
49
-2008128Conduit Fittings
50
-2008132Conduits
51
-2008083Data Devices
52
-2008016Duct Accessories
53
-2008010Duct Fittings
54
-2008015Duct Systems
55
-2008000Ducts
56
-2001040Electrical Equipment
57
-2001060Electrical Fixtures
58
-2008085Fire Alarm Devices
59
-2008020Flex Ducts
60
-2008050Flex Pipes
61
-2008107HVAC Zones
62
-2008087Lighting Devices
63
-2001120Lighting Fixtures
64
-2001140Mechanical Equipment
65
-2008077Nurse Call Devices
66
-2008055Pipe Accessories
67
-2008049Pipe Fittings
68
-2008044Pipes
69
-2008043Piping Systems
70
-2001160Plumbing Fixtures
71
-2008079Security Devices
72
-2003600Spaces
73
-2008099Sprinklers
74
-2008101Switch System
75
-2008075Telephone Devices
76
-2008039Wires
77
Structural-2005301Boundary Conditions
78
-2009013Rebar Shape
79
-2009003Structural Area Reinforcement
80
-2001327Structural Beam Systems
81
-2001330Structural Columns
82
-2009030Structural Connections
83
-2001300Structural Foundations
84
-2001320Structural Framing
85
-2009009Structural Path Reinforcement
86
-2009000Structural Rebar
87
-2001354Structural Stiffeners
88
-2001336Structural Trusses
89
90
91
92
93
PARAMETERS
94
The Parameters tab can be used to create Shared Parameters in the Revit model. This is functionality for advanced Revit users and should be tested thoroughly to understand how it works and the limitations. Parameters identified here will be automatically created in the Revit model if they are not in there already.
Information in Rows 1, 2, and 3 should not be edited.
There can only be a single Parameters tab in a Classification Manager database Excel file.
The structure of the tab is designed to allow users to copy/paste from an already created Shared Parameters text file. Do not copy any of the "header" information from the Shared Parameters text file. Paste the copied text into cell B4.
Only the following data types are accepted: “TEXT”, “INTEGER”, “NUMBER”, “YESNO”, and “URL”
Extra information can be added in the first column A - TYPE v INSTANCE. Putting TYPE in this field will add the parameter at the TYPE level. INSTANCE will add it at the INSTANCE level. If no information is here, the parameter will attach at the TYPE level for appropriate categories.
Parameters will be bound to all default Classification Manager categories based on the Function of the classification that uses them: Facility classification parameters will bind to Project Information; Spaces classification parameters will bind to Rooms and Spaces; Element classification parameters will bind to the default model categories for Classification Manager.
95
96
97
98
99
100