NameTypeFrequency
Wavelength
In-air/In-vacuum
Ser. Num.LocationDesctription
iKAGRA?
2
PMCR RF PDfPMC,DC
1064nm
In-air PSL tablePMC reflection yes
3
PMCT DC PDDC
1064nm
In-air PSL tablePMC transmission yes
4
REFCAVRRF PDfIMC,DC
1064nm
In-air PSL tableFRC reflection yes
5
REFCAVTDC PDDC
1064nm
In-air PSL tableFRC transmission yes
6
IP_ADC QPDDC
1064nm
In-air PSL tableinput pointing to IMC yes
7
IP_BDC QPDDC
1064nm
In-air PSL tableinput pointing to IMC yes
8
RFAMRDC PDDC
1064nm
In-airPSL tableRF AM Mach-Zehnder lock
9
RFAMTDC PDDC
1064nm
In-airPSL tableRF AM Mach-Zehnder lock
10
RFAMDLINERF PDfIMC,DC
1064nm
In-airPSL tableRF AM delay-line lock
11
IMCRRF PDfIMC,DC
1064nm
In-air IMC REFL tableIMC reflection yes
12
IMCR_ARF QPDfIMC,DC
1064nm
In-air IMC REFL tableIMC reflection WFS yes
13
IMCR_BRF QPDfIMC,DC
1064nm
In-air IMC REFL tableIMC reflection WFS yes
14
IMCTDC PDDC
1064nm
In-air IMC TRANS tableIMC transmission yes
15
IMCT_ADC QPDDC
1064nm
In-air IMC TRANS tableIMC transmission pointing yes
16
IMCT_BDC QPDDC
1064nm
In-air IMC TRANS tableIMC transmission pointing yes
17
REFLRF PDf1,f2,DC
1064nm
In-air REFL tableDRFPMI reflection yes
18
REFLNRSBRF PD
f3-f1,f3-f2,DC
1064nm
In-air REFL tableDRFPMI reflection, for nonresonant SB
19
REFL_ARF QPDf1,f2,DC
1064nm
In-air REFL tableDRFPMI reflection
20
REFL_BRF QPDf1,f2,DC
1064nm
In-air REFL tableDRFPMI reflection
21
IMMT1TDC PDDC
1064nm
In-air
pylon close to IMM chamber
IMMT1 transmission, power monitor yes
22
IMMT2TRF PDf1,f2,DC
1064nm
In-air IMMT2 table
IMMT2 transmission, power/RFAM monitor
yes
23
IMMT2T_ADC QPDDC
1064nm
In-air IMMT2 table
IMMT2 transmission, input pointing to DRFPMI
yes
24
IMMT2T_BDC QPDDC
1064nm
In-air IMMT2 table
IMMT2 transmission, input pointing to DRFPMI
yes
25
POPRF PDf1,f2,DC
1064nm
In-air POP tablePRC pick-off
26
POP_ARF QPDf1,f2,DC
1064nm
In-air POP tablePRC pick-off
27
POP_BRF QPDf1,f2,DC
1064nm
In-air POP tablePRC pick-off
28
SPOPRF PD2*f1,2*f2,DC
1064nm
In-air POP table
PRC pick-off, sideband build-up monitor
29
POP_GRRF PDfALSX,DC532nmIn-air POP tableALSX reflection
30
PLLXBB PDBB,DC
1064nm
In-airPOP tablePLL for ALSX
31
SPOSRF PD2*f1,2*f2,DC
1064nm
In-air POS table
SRC pick-off, sideband build-up monitor
32
POS_GRRF PDfALSY,DC532nmIn-air POS tableALSY reflection
33
PLLYBB PDBB,DC
1064nm
In-airPOS tablePLL for ALSY
34
POXRF PDf1,f2,DC
1064nm
In-air POX tableX arm reflection
35
POYRF PDf1,f2,DC
1064nm
In-air POY tableY arm reflection
36
TRXDC PDDC
1064nm
In-air TRX tableETMX transmission
37
TRX_ADC QPDDC
1064nm
In-air TRX tableETMX transmission pointing
38
TRX_BDC QPDDC
1064nm
In-air TRX tableETMX transmission pointing
39
TRX_GRDC PDDC532nmIn-air TRX tableALSX transmission
40
TRX_GR_ADC QPDDC532nmIn-air TRX tableALSX transmission pointing
41
TRX_GR_BDC QPDDC532nmIn-air TRX tableALSX transmission pointing
42
TRYDC PDDC
1064nm
In-air TRY tableETMY transmission
43
TRY_ADC QPDDC
1064nm
In-air TRY tableETMY transmission pointing
44
TRY_BDC QPDDC
1064nm
In-air TRY tableETMY transmission pointing
45
TRY_GRDC PDDC532nmIn-air TRY tableALSY transmission
46
TRY_GR_ADC QPDDC532nmIn-air TRY tableALSY transmission pointing
47
TRY_GR_BDC QPDDC532nmIn-air TRY tableALSY transmission pointing
48
ASRF PDf1,DC
1064nm
In-air AS tableDRFPMI anti-symmetric
49
AS_ARF QPDf1,DC
1064nm
In-air AS tableDRFPMI anti-symmetric
50
AS_BRF QPDf1,DC
1064nm
In-air AS tableDRFPMI anti-symmetric
51
OMCTDC PDDC
1064nm
In-air AS tableDRFPMI DC readout
52
OMCT_ADC QPDDC
1064nm
In-air AS tableOMC alignment
53
OMCT_BDC QPDDC
1064nm
In-air AS tableOMC alignment
54
IMCTVAC_ADC QPDDC
1064nm
In-vacMCE chamberIMC transmission pointing
55
IMCTVAC_BDC QPDDC
1064nm
In-vac MCE chamberIMC transmission pointing
56
IMMT1TVACDC PDDC
1064nm
In-vac IMM chamberIMMT1 transmission, for ISS
57
IMMT2TVACDC PDDC
1064nm
In-vac IFI chamberIMMT2 transmission, for ISS
58
IMMT2TVAC_A
DC QPDDC
1064nm
In-vac IFI chamber
IMMT2 transmission, input pointing to DRFPMI
59
IMMT2TVAC_B
DC QPDDC
1064nm
In-vac IFI chamber
IMMT2 transmission, input pointing to DRFPMI
60
REFLVACRF PDf1,f2,DC
1064nm
In-vac IFI chamberDRFPMI reflection
61
REFLVAC_ARF QPDf1,f2,DC
1064nm
In-vac IFI chamberDRFPMI reflection
62
REFLVAC_BRF QPDf1,f2,DC
1064nm
In-vac IFI chamberDRFPMI reflection
63
POPVACRF PDf1,f2,DC
1064nm
In-vac PR2 chamberPRC pick-off
64
POPVAC_ARF QPDf1,f2,DC
1064nm
In-vac PR2 chamberPRC pick-off
65
POPVAC_BRF QPDf1,f2,DC
1064nm
In-vac PR2 chamberPRC pick-off
66
POXVACRF PDf1,f2,DC
1064nm
In-vac SR3 chamberX arm reflection
67
POYVACRF PDf1,f2,DC
1064nm
In-vac SR3 chamberY arm reflection
68
TRXVAC_ADC QPDDC
1064nm
In-vac EXT chamberETMX transmission pointing
69
TRXVAC_BDC QPDDC
1064nm
In-vac EXT chamberETMX transmission pointing
70
TRXVAC_GR_A
DC QPDDC532nmIn-vac EXT chamberALSX transmission pointing
71
TRXVAC_GR_B
DC QPDDC532nmIn-vac EXT chamberALSX transmission pointing
72
TRYVAC_ADC QPDDC
1064nm
In-vac EYT chamberETMY transmission pointing
73
TRYVAC_BDC QPDDC
1064nm
In-vac EYT chamberETMY transmission pointing
74
TRYVAC_GR_A
DC QPDDC532nmIn-vac EYT chamberALSY transmission pointing
75
TRYVAC_GR_B
DC QPDDC532nmIn-vac EYT chamberALSY transmission pointing
76
ASVACRF PDf1,DC
1064nm
In-vac OMM chamberDRFPMI anti-symmetric
77
ASVAC_ARF QPDf1,DC
1064nm
In-vac OMM chamberDRFPMI anti-symmetric
78
ASVAC_BRF QPDf1,DC
1064nm
In-vac OMM chamberDRFPMI anti-symmetric
79
OMCTVACDC PDDC
1064nm
In-vac OMM chamberDRFPMI DC readout
80
OMCTVAC_ADC QPDDC
1064nm
In-vac OMM chamberOMC alignment
81
OMCTVAC_BDC QPDDC
1064nm
In-vac OMM chamberOMC alignment