A | B | C | D | E | F | G | H | I | J | K | L | M | N | P | Q | R | S | T | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | MPP Solar | |||||||||||||||||||
2 | European Inverter | European Inverter | European Inverter | |||||||||||||||||
3 | PIP 1012 LV-MK | PIP 2024 LV-MK | PIP 3048 LV-MK | LV 6048 | LVX 6048 | LVX 6048 WP | LV 6548 | PIP 1012 LV-MS | PIP 2424 LV-MSD | HV LV 2424 | PIP 2724 LV-MR | PIP 8048 MAX | PIP 5048 MKX | U5648MS | ||||||
4 | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | Solar Charger Mode | ||||||
5 | Max PV Input Voltage (Voc) | 145VDC | 145VDC | 145VDC | 145VDC | 450VDC | 600VDC | 250VDC | 102VDC | 145VDC | 145VDC | 60VDC | 500VDC | 500VDC | 450VDC | |||||
6 | MPPT Voltage Range | 15 - 115VDC | 30 - 115VDC | 60 - 115VDC | 60 - 115VDC | 120 - 430VDC | 120 - 550VDC | 90 - 230VDC | 15 - 80VDC | 30 - 80VDC | 30 - 115VDC | 30 - 50VDC | 90 - 450VDC | 120 - 450VDC | 120 - 430VDC | |||||
7 | Number of Input Strings | 1 | 1 | 1 | 2 | 1 | 2 | 2 | 1 | 1 | 1 | 1 | 2 | 1 | 1 | |||||
8 | Max PV Input Current | 50A | 50A | 50A | 50A + 50A | 27A | 15A per input | 18A per input (2 x 10A strings OK) | 30A | 50A | 50A | 15A | 18A per input (2 x 10A strings OK) | 27A | 27A | |||||
9 | Max Charge Current to Battery | 80A | 80A | 80A | 80A + 80A | 100A | 60A + 60A | 60A + 60A | 40A | 80A | 80A | 25A | 60A + 60A | 100A | 120A | |||||
10 | Max PV Input Power to Battery | 1000W | 2000W | 4000W | 4000W + 4000W | 5000W | 3000W + 3000W | 3500W + 3500W | 500W | 2000W | 2000W | 750W | 4000W + 4000W | 6000W | 6000W | |||||
11 | Reccomended Cable Size for PV Connection | 10AWG | 8AWG | 6AWG | 8AWG | 10AWG | 12AWG | 10-12 AWG | 10AWG | 6AWG | 6AWG | 12AWG | 10-12 AWG | 10AWG | 10AWG | |||||
12 | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | AC Charger Mode | ||||||
13 | AC Input | 120VAC | 120VAC | 120VAC | 120VAC/240VAC (Depending on setting 28) | 240VAC Only | 240VAC Only | 120VAC | 120VAC | 120VAC | 120VAC | 120VAC | 240VAC Only (European) | 240VAC Only (European) | 240VAC Only (European) | |||||
14 | Reccomended Breaker for AC Input | 15A | 25A | 40A | 40A Double Pole | 40A Double Pole | 40A Double Pole | 60A | 15A | 25A | 25A | 30A | 30A | 25A | 30A | |||||
15 | Max AC Charge Current (from Utility/Generator) | 6A @ 120V | 12A @ 120V | 24A @ 120V | 24A @ 120V, 12A @ 240V | 20A @ 240V | 24A @ 240V | 48A @ 120V | 2A @ 120V | 12A @ 120V | 12A @ 120V | 5A @ 120V | 24A @ 240V | 20A @ 240V | 24A @ 240V | |||||
16 | Max DC Charge Current (to Battery) | 60A @ 12V | 60A @ 24V | 60A @ 48V | 60A @ 48V | 100A @ 48V | 120A @48V | 120A @ 48V | 20A @ 12V | 60A @ 24V | 60A @ 24V | 25A @ 24V | 120A @ 48V | 100A @ 48V | 120 @ 48V | |||||
17 | ||||||||||||||||||||
18 | Max System Charge Current to Battery (Solar + AC) | 140A | 140A | 140A | 220A | 100A | 120A | 120A | 60A | 140A | 140A | 25A | 120A | 100A | 120A | |||||
19 | Battery Required to Operate | Required | Required | Required | Required | Not Required | Not Required | Not Required | Required | Required | Required | Required | Not Required | Not Required | Not Required | |||||
20 | Reccomended AC Input and Output Cable Size | 14AWG | 12AWG | 10AWG | 10AWG | 10AWG | 8-10 AWG | 4AWG | 16AWG | 10AWG | 10AWG | 10AWG | 8AWG | 8AWG | 10AWG | |||||
21 | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | Inverter Mode | ||||||
22 | Battery Input Voltage Range | 10 - 16VDC | 20 - 32VDC | 40 - 64VDC | 40 - 60VDC | 42 - 58VDC | 40 - 62VDC | 40 - 66VDC | 10 - 15VDC | 20 - 31VDC | 20 - 31VDC | 20 - 31VDC | 40 - 66VDC | 40 - 64VDC | 40 - 66VDC | |||||
23 | Max Battery Input Current | 83A | 83A | 62A | 125A | 125A | 125A | 135A | 83A | 100A | 100A | 112A | 167A | 104A | 116A | |||||
24 | Reccomended Breaker for Battery Input | 120A | 120A | 120A | 200A | 200A | 200A | 200A | 120A | 120A | 120A | 150A | 200A | 150A | 150A | |||||
25 | Reccomended Battery Cable Size | 4AWG | 4AWG | 4AWG | 1/0AWG or 2 x 4AWG | 2AWG | 3/0AWG | 2/0AWG | 4AWG or 2 x 8AWG | 2AWG or 2 x 6AWG | 2AWG or 2 x 6AWG | Built-In | 2/0AWG | 1/0AWG or 2 x 4AWG | 2AWG or 2 x 6AWG | |||||
26 | Battery Type | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | Lead-Acid / Lithium | |||||
27 | Rated Power | 1000VA / 1000W | 2000VA / 2000W | 3000VA / 3000W | 6000VA / 6000W | 6000VA / 6000W | 6000VA / 6000W | 6500VA / 6500W | 1000VA / 1000W | 2400VA / 2400W | 2400VA / 2400W | 2700VA / 2700W | 8000VA / 8000W | 5000VA / 5000W | 5600VA / 5600W | |||||
28 | Surge Capacity | 2kW for 5 seconds | 4kW for 5 seconds | 6kW for 5 seconds | 12kW for 5 seconds | 12kW | 12kW | 13kW for 5 seconds | 2kW for 5 seconds | 4.8kW for 5 seconds | 4.8kW | 5.4kW for 5 seconds | 16kW for 5 seconds | 10kW for 5 seconds | 11.2kW for 5 seconds | |||||
29 | AC Output | 8A @ 120VAC | 16A @ 120VAC | 25A @ 120VAC | 25A @ 240VAC 25A @ 120VAC (3kW per phase) | 25A @ 240VAC 25A @ 120VAC (3kW per phase) | 25A @ 240VAC 25A @ 120VAC (3kW per phase) | 54A @ 120VAC | 8A @ 120VAC | 20A @ 120VAC | 20A @ 120VAC | 22A @ 120VAC | 33A @ 240VAC (European) | 21A @ 240VAC (European) | 23A @ 240VAC (European) | |||||
30 | Reccomended Breaker for AC Output | 10A | 20A | 30A | 30A per phase | 30A per phase | 30A per phase | 60A | 10A | 25A | 25A | 30A | 40A | 25A | 30A | |||||
31 | Standby Inverter Power Usage | <30W | <30W | <40W | <100W | <150W | <120W | <70W | <15W (<5W Power Save Mode) | <50W (<15W Power Save Mode) | <25W | <70W | <75W | |||||||
32 | Environment | Environment | Environment | Environment | Environment | Environment | Environment | Environment | Environment | Environment | Environment | Environment | Environment | Environment | ||||||
33 | Shipping Dimensions (L x W x H) (inches) | 23 x 16 x 9 | 23 x 16 x 8 | 23 x 16 x 8 | 31 x 26 x 10 | 28 x 22 x 10 | 28 x 22 x 15 | 28 x 22 x 10 | 20 x 16 x 9 | 23 x 16 x 9 | 23 x 16 x 9 | 20 x 19 x 8 | 28 x 22 x 10 | 20 x 12 x 6 | 24 x 16 x 9 | |||||
34 | Operating temperature range | Up to 55C | Up to 50C | Up to 50C | Up to 50C | Up to 50C | Up to 60C | Up to 40C | Up to 55C | Up to 55C | Up to 50C | Up to 55C | Up to 50C | Up to 50C | Up to 50C | |||||
35 | Display | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED | |||||
36 | Level of Protection | CE Certified | CE Certified | CE Certified | CE Certified | CE Certified | IP65, UL Compliant | UL Compliant | CE Certified | CE Certified | CE Certified | CE Certified | CE Certified | |||||||
37 | Communication | RS232, USB, Wi-Fi (Optional) | RS232, USB, Wi-Fi (Optional) | RS232, USB, Wi-Fi (Optional) | RS232, USB, Wi-Fi (Optional) | Built-In WIFI, RS232, Dry-Contact | Built-In WIFI, USB, RS232, RS485, Dry Contact | Built-In WIFI | Wi-Fi Optional | USB, RS232, Wi-Fi (Optional) | USB, RS232, Dry Contact, Wi-Fi (Optional) | USB, R232, Wi-Fi (Optional) | Built-In WIFI | USB, RS232/RS485, Built-In WIFI, Dry Contact | USB, RS232, RS485, Built-In WIFI, Dry Contact | |||||
38 | Parallelable | Yes (Up to 9) | Yes (Up to 9) | Yes (Up to 9) | Yes (Up to 3) | Yes (Up to 9) | Yes (Up to 6) | Yes (Up to 6) | No | Yes (Up to 6) | Yes (Up to 9) | No | Yes (Up to 6) | Yes (Up to 9) | Yes (Up to 9) | |||||
39 | Highlights | 12V Battery System 1kW Inverter 0ms Transfer Time Split Phase with 2 or more 3-Phase with 3 or more Expandable up to 9kW (9 Units) One Parallel kit per inverter | 24V Battery System 2kW Inverter 0ms Transfer Time Split Phase with 2 or more 3-Phase with 3 or more Expandable up to 18kW (9 Units) One Parallel kit per inverter | 48V Battery System 3kW Inverter 0ms Transfer Time Split Phase with 2 or more 3-Phase with 3 or more Expandable up to 27kW (9 Units) One Parallel kit per inverter | 48V Battery System Dual PV Inputs with Two 80A Charge Controllers Capable of 6kW at 120VAC output Capable of 3kW per phase at 120/240VAC output 6kW Inverter (Two 3kW Inverters in one) 3-Phase output with 3 units Expandable up to 18kW (3 Units) Parallel kit Built In | Capable of Batteryless Operation 48V Battery System Very High PV input voltage (450VDC) 120VAC AND 240VAC output simultaneously 6kW Inverter (3kW per phase) Expandable up to 54kW (9 Units) One Parallel kit per inverter Built-In WIFI monitoring Not 3-Phase Capable Non UL Listed Grid Feedback (Option) | IP65 Waterproof Outdoors Capable of Batteryless Operation 48V Battery System Very High PV input voltage (600VDC) Dual PV Inputs with Two 60A charge controllers 120VAC AND 240VAC output simultaneously 6kW Inverter (3kW per phase) Expandable up to 54kW (9 Units) Parallel kit Built In Built-In WIFI monitoring Not 3-Phase Capable UL Compliant Grid Feedback | Capable of Batteryless Operation 48V Battery System High PV input voltage (250VDC) Dual PV Inputs with Two 60A charge controllers Built-In WIFI monitoring UL Compliant 6.5kW Inverter Expandable up to 39kW (6 units) Parallel kit Built In | 12V Battery System 1kW Inverter Simple, Low Cost Not Expandable Ideal for TV, Fridges, Low-Usage Applications | 24V Battery System 2.4kW Inverter Simple/Easy Terminal Connections Con: Noisy fans Expandable up to 14.4kW (6 Units) One Parallel kit per inverter Compatible Output: 120VAC, 208VAC and 3-phase Not 240VAC output capable | 24V Battery System 2.4kW Inverter Expandable up to 21.6kW (9 Units) One Parallel kit per inverter Split Phase with 2 or more 3-Phase with 3 or more Non UL Listed Grid Feedback Capable | 24V Battery System 2.7kW Inverter Easy Connections Quick Set-up Con: 750W/60V max PV input | Capable of Batteryless Operation 48V Battery System European 220-240VAC Only Dual PV Inputs with Two 60A Charge Controllers Very High PV input voltage (500VDC) Built-In WIFI Monitoring 8kW Inverter Expandable up to 48kW (6 Units) One Parallel kit per inverter BMS Support (Pylontech, Weco, Soltaro) – Separate BMS cable required Used for 240VAC Appliances EV charging, pool and well pumps, AC units | Capable of Batteryless Operation 48V Battery System European 220-240VAC Only Very High PV input voltage (500VDC) Built-In WIFI Monitoring 5kW Inverter Expandable up to 45kW (9 Units) One Parallel kit per inverter Used for 240VAC Appliances EV charging, pool and well pumps, AC units | Capable of Batteryless Operation 48V Battery System European 220-240VAC Only Very High PV input voltage (450VDC) Built-In WIFI Monitoring 5.6kW Inverter Expandable up to 50.4kW (9 Units) One Parallel kit per inverter Used for 240VAC Appliances EV charging, pool and well pumps, AC units | |||||
40 | Features/Limitations of 1kW LV-MK and LV-MS | Features/Limitations of 1kW LV-MK and LV-MS | Features/Limitations of 1kW LV-MK and LV-MS | LVX6048 Parallel Setup | LVX 6048 WP First Look | LV 6548 Batteryless Overview | Features/Limitations of 1kW LV-MK and LV-MS | LV2424 MSD with load test | HV LV 2424 Quick Look | LV2724 MR with load test | ||||||||||
41 | Motorhome installations 1012 LV-MK | LVX6048 Batteryless Operation | ||||||||||||||||||
42 | Welding battery-less with the LVX6048 | |||||||||||||||||||
43 | ||||||||||||||||||||
44 | ||||||||||||||||||||
45 | ||||||||||||||||||||
46 | ||||||||||||||||||||
47 | ||||||||||||||||||||
48 | ||||||||||||||||||||
49 | ||||||||||||||||||||
50 | ||||||||||||||||||||
51 | ||||||||||||||||||||
52 | ||||||||||||||||||||
53 | ||||||||||||||||||||
54 | ||||||||||||||||||||
55 | ||||||||||||||||||||
56 | ||||||||||||||||||||
57 | ||||||||||||||||||||
58 | ||||||||||||||||||||
59 | ||||||||||||||||||||
60 | ||||||||||||||||||||
61 | ||||||||||||||||||||
62 | ||||||||||||||||||||
63 | ||||||||||||||||||||
64 | ||||||||||||||||||||
65 | ||||||||||||||||||||
66 | ||||||||||||||||||||
67 | ||||||||||||||||||||
68 | ||||||||||||||||||||
69 | ||||||||||||||||||||
70 | ||||||||||||||||||||
71 | ||||||||||||||||||||
72 | ||||||||||||||||||||
73 | ||||||||||||||||||||
74 | ||||||||||||||||||||
75 | ||||||||||||||||||||
76 | ||||||||||||||||||||
77 | ||||||||||||||||||||
78 | ||||||||||||||||||||
79 | ||||||||||||||||||||
80 | ||||||||||||||||||||
81 | ||||||||||||||||||||
82 | ||||||||||||||||||||
83 | ||||||||||||||||||||
84 | ||||||||||||||||||||
85 | ||||||||||||||||||||
86 | ||||||||||||||||||||
87 | ||||||||||||||||||||
88 | ||||||||||||||||||||
89 | ||||||||||||||||||||
90 | ||||||||||||||||||||
91 | ||||||||||||||||||||
92 | ||||||||||||||||||||
93 | ||||||||||||||||||||
94 | ||||||||||||||||||||
95 | ||||||||||||||||||||
96 | ||||||||||||||||||||
97 | ||||||||||||||||||||
98 | ||||||||||||||||||||
99 | ||||||||||||||||||||
100 |