| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Login | 1234 | of 4335 | Belangrijke settings | ||||||||||||||||||||||
2 | Admin Login | 123456 | ||||||||||||||||||||||||
3 | ||||||||||||||||||||||||||
4 | Basic Settings | |||||||||||||||||||||||||
5 | Cell Count: | 16 | Calibrating Volt. (V): | 55,212 | ||||||||||||||||||||||
6 | Battery Capacity (AH): | 314 | Calibrating Cur. (A): | 6,998 | ||||||||||||||||||||||
7 | Balance Trig Volt. (V): | 0,001 | ||||||||||||||||||||||||
8 | ||||||||||||||||||||||||||
9 | Advance Settings | |||||||||||||||||||||||||
10 | Start Balance Volt. (V): | 3,450 | Charge UTPR °C: | 4 | Charge Under Temperature Protection Recovery | |||||||||||||||||||||
11 | Max Balance Cur.(A): | 2,0 | MOS OIP °C: | 90 | MOS Over Current Protection Temperature | The temperature at which the MOSFETs (the power switches) are protected from overcurrent by the BMS. If the temperature exceeds this threshold, the system will shut down the discharge or charge to protect the MOSFETs. | ||||||||||||||||||||
12 | Cell OVP (V): | 3,650 | Cell Over Voltage Protection Voltage | The voltage at which the BMS will stop charging to prevent overvoltage damage to the cells. | MOS OTPR °C: | 70 | MOS Over Temperature Protection Recovery | The temperature at which the MOSFETs can resume normal operation after being shut down due to overtemperature protection. Once the MOSFETs cool down below this value, the system can recover and resume charging or discharging. | ||||||||||||||||||
13 | Vol. Cell RCV (V): | 3,450 | Cell Voltage Recovery Voltage | The voltage threshold at which the BMS will check if the cells are safe to resume charging after an overvoltage protection event. This is a recovery threshold after an overvoltage event occurs. | SCP Delay (µs): | 1000 | Short Circuit Protection | |||||||||||||||||||
14 | SOC-100%Volt. (V): | 3,449 | SOC 100% Voltage | The voltage at which the battery is considered to be at 100% State of Charge (SOC). | SCPR Time (S): | 60 | Short Circuit Protection Recovery time | |||||||||||||||||||
15 | Cell OVPR (V): | 3,448 | Cell Over Voltage Protection Recovery | The voltage at which the system will allow charging to resume after a cell overvoltage event, once the cell voltage drops back down. | Dischrg. Pre. Chrg. T(S): | 5 | Discharge Pre-Charge Time | This setting refers to the amount of time (in seconds) that the BMS waits before starting a discharge operation after a pre-charge has been completed. Essentially, it’s a delay period before the system begins discharging after certain conditions have been met. | ||||||||||||||||||
16 | Cell UVPR (V): | 3,05 | Cell Under Voltage Protection Recovery | The voltage at which the system will allow charging or discharging to resume after an under-voltage event. After a cell dips below the UVP (Under Voltage Protection) threshold, the system checks to see if it has recovered to this level before resuming operation. | Device Addr: | 1 | ||||||||||||||||||||
17 | SOC-0% Volt. (V): | 2,9 | SOC 0% Voltage | Data Stored Period (S): | 864000 | |||||||||||||||||||||
18 | Cell UVP (V): | 2,85 | Cell Under Voltage Protection | The voltage at which the BMS will stop discharging to prevent deep discharge of the cells, which could cause irreversible damage. | RCV Time (H): | 1 | Recovery Check Voltage Time | The interval (in hours) at which the BMS checks the battery for voltage recovery after it has entered a protection state (e.g., overvoltage or undervoltage). | ||||||||||||||||||
19 | Power Off VoL. (V): | 2,7 | Power Off Voltage | The voltage at which the system will turn off and stop all operations, usually to prevent deep discharge or excessive energy drain when the battery is low. | RFV Time(H): | 9 | Rebalance Forced Voltage Time | The interval (in hours) at which the BMS performs a forced voltage balancing cycle to ensure that all cells remain at similar voltages. | ||||||||||||||||||
20 | Vol. Cell RFV (V): | 3,35 | Cell Voltage Rebalance Voltage | The voltage at which the BMS will start balancing the cells. This setting is related to how the BMS triggers the balancing process if there's a voltage difference between cells. | User Private Data: | JK-BMS | ||||||||||||||||||||
21 | Vol. Smart Sleep (V): | 3 | Voltage Smart Sleep | The voltage at which the BMS enters "smart sleep" mode to reduce power consumption when the system is not in use. This feature is designed to conserve battery power while still monitoring voltage levels. | User Data 2: | JK-BMS | ||||||||||||||||||||
22 | Time Smart Sleep(h): | 24 | UART1 Protocol No: | 000-4G-GPS Remote module Common protocol V4,2 | ||||||||||||||||||||||
23 | Continued Charge Curr.(A): | 120 | UART2 Potocol No: | 001-JK BMS RS485 Modbus V1.0 | ||||||||||||||||||||||
24 | Charge OCP Delay (S): | 30 | Over Current Protection time | CAN Potocol No: | 004-Victron CANbus BMS protocol20170717 | |||||||||||||||||||||
25 | Charge OCPR Time (S): | 60 | Over Current Protection Recovery time | LCD Buzzer Trigger: | 09-MOSFET Over Temperature | |||||||||||||||||||||
26 | Continued Discharge Curr.(A): | 120 | LCD Buzzer Trigger Val: | 100 | ||||||||||||||||||||||
27 | Discharge OCP Delay (S): | 300 | Over Discharge Current Protection time | LCD Buzzer Release Val: | 95 | |||||||||||||||||||||
28 | Discharge OCPR Time (S): | 60 | Over Discharge Current Protection Recovery time | DRY 1 Trigger: | 08-Battery Over Temperature | |||||||||||||||||||||
29 | Charge OTP °C: | 50 | Charge Over Temperature Protection | DRY 1 Trigger Val: | 60 | |||||||||||||||||||||
30 | Charge OTPR °C: | 45 | Charge Over Temperature Protection Recovery | DRY 1 Release Val: | 50 | |||||||||||||||||||||
31 | Discharge OTP °C: | 50 | Discharge Over Temperature Protection | DRY 2 Trigger: | 00 - OFF | |||||||||||||||||||||
32 | Discharge OTPR °C: | 45 | Discharge Over Temperature Protection Recovery | DRY 2 Trigger Val: | 0 | |||||||||||||||||||||
33 | Charge UTP(°C): | 2 | Charge Under Temperature Protection. | DRY 2 Release Val: | 0 | |||||||||||||||||||||
34 | ||||||||||||||||||||||||||
35 | ||||||||||||||||||||||||||
36 | ||||||||||||||||||||||||||
37 | ||||||||||||||||||||||||||
38 | ||||||||||||||||||||||||||
39 | ||||||||||||||||||||||||||
40 | ||||||||||||||||||||||||||
41 | ||||||||||||||||||||||||||
42 | ||||||||||||||||||||||||||
43 | ||||||||||||||||||||||||||
44 | ||||||||||||||||||||||||||
45 | ||||||||||||||||||||||||||
46 | ||||||||||||||||||||||||||
47 | ||||||||||||||||||||||||||
48 | ||||||||||||||||||||||||||
49 | ||||||||||||||||||||||||||
50 | ||||||||||||||||||||||||||
51 | ||||||||||||||||||||||||||
52 | ||||||||||||||||||||||||||
53 | ||||||||||||||||||||||||||
54 | ||||||||||||||||||||||||||
55 | ||||||||||||||||||||||||||
56 | ||||||||||||||||||||||||||
57 | ||||||||||||||||||||||||||
58 | ||||||||||||||||||||||||||
59 | ||||||||||||||||||||||||||
60 | ||||||||||||||||||||||||||
61 | ||||||||||||||||||||||||||
62 | ||||||||||||||||||||||||||
63 | ||||||||||||||||||||||||||
64 | ||||||||||||||||||||||||||
65 | ||||||||||||||||||||||||||
66 | ||||||||||||||||||||||||||
67 | ||||||||||||||||||||||||||
68 | ||||||||||||||||||||||||||
69 | ||||||||||||||||||||||||||
70 | ||||||||||||||||||||||||||
71 | ||||||||||||||||||||||||||
72 | ||||||||||||||||||||||||||
73 | ||||||||||||||||||||||||||
74 | ||||||||||||||||||||||||||
75 | ||||||||||||||||||||||||||
76 | ||||||||||||||||||||||||||
77 | ||||||||||||||||||||||||||
78 | ||||||||||||||||||||||||||
79 | ||||||||||||||||||||||||||
80 | ||||||||||||||||||||||||||
81 | ||||||||||||||||||||||||||
82 | ||||||||||||||||||||||||||
83 | ||||||||||||||||||||||||||
84 | ||||||||||||||||||||||||||
85 | ||||||||||||||||||||||||||
86 | ||||||||||||||||||||||||||
87 | ||||||||||||||||||||||||||
88 | ||||||||||||||||||||||||||
89 | ||||||||||||||||||||||||||
90 | ||||||||||||||||||||||||||
91 | ||||||||||||||||||||||||||
92 | ||||||||||||||||||||||||||
93 | ||||||||||||||||||||||||||
94 | ||||||||||||||||||||||||||
95 | ||||||||||||||||||||||||||
96 | ||||||||||||||||||||||||||
97 | ||||||||||||||||||||||||||
98 | ||||||||||||||||||||||||||
99 | ||||||||||||||||||||||||||
100 |