wind turbine vs building cer comparison
 Share
The version of the browser you are using is no longer supported. Please upgrade to a supported browser.Dismiss

 
View only
 
 
Still loading...
ABCDEF
1
Wind farm in China
2
1mW per turbine
3
50# of turbines
4
50total mW
5
2190hours per year(25 % capacity factor)
6
109500total annual mWh
7
1carbon factor (tons/ mWh)source: AES
8
109500CERs
9
$2,190,000Annual wind farm income stream from CERs
10
Building in China
11
150,000Square meters
12
200Energy use per square meter (kWh/ square meter)(LBL report 1036E)
13
30000000Baseline energy use per year (kWh)
14
0.001Carbon factor (tons/ kWh)
15
30000Baseline carbon emissions
16
50%Efficiency improvement
17
18
15000CERsCERs per square meter0.1
19
Portfolio size needed to match 50 mW wind farm1095000
20
21
$20Dollars per ton
22
$300,000Annual building income stream from CERs
23
$0.1Cost per kWh
24
$1,500,000Annual energy billKicker from CERs20.00%
Loading...
 
 
 