1 | _ENUM_GROUPS | TOKEN | NUM_VALUE | ApplicationDescription | Tags | |||||||||||||||||||||
2 | Enums with updated/added descriptions | |||||||||||||||||||||||||
3 | _MDC_PUMP_DELIV_STAT | pump-delivery-status-delivering | The pump is currently delivering the fluid at the programmed rate. | ds-ip-rel_2.0 | MDC_DEV_PUMP_CURRENT_DELIVERY_STATUS | |||||||||||||||||||||
4 | _MDC_PUMP_DELIV_STAT | pump-delivery-status-not-delivering | The pump is not currently delivering. See _MDC_PUMP_NOT_DELIVERING_REASON | ds-ip-rel_2.0 | ||||||||||||||||||||||
5 | _MDC_PUMP_DELIV_STAT | pump-delivery-status-kvo | The pump is currently delivering the fluid at a programmed KVO rate. | ds-ip-rel_2.0 | ||||||||||||||||||||||
6 | _MDC_PUMP_DELIV_STAT | pump-delivery-status-flushing | The pump is currently flushing the fluid line. | ds-ip-rel_2.0 | ||||||||||||||||||||||
7 | _MDC_PUMP_DELIV_STAT | pump-delivery-status-transitioning | The pump is currently tranistioning to a new rate, new device during a relay or infusate source. | ds-ip-rel_2.0 | ||||||||||||||||||||||
8 | _MDC_PUMP_NOT_DELIVERING_REASON | pump-stopped-priming | Pump is stopped because it completed priming or was stopped during during priming. | ds-ip-rel_2.0 | ||||||||||||||||||||||
9 | _MDC_PUMP_NOT_DELIVERING_REASON | pump-stopped-delayed | Pump is stopped while waiting for a programmed delay period to expire. | ds-ip-rel_2.0 | ||||||||||||||||||||||
10 | _MDC_PUMP_NOT_DELIVERING_REASON | pump-stopped-alarming | Pump is stopped due to an alarm condition. | ds-ip-rel_2.0 | ||||||||||||||||||||||
11 | _MDC_PUMP_NOT_DELIVERING_REASON | pump-stopped-by-clinician | Pump was stopped by a clinician. | ds-ip-rel_2.0 | ||||||||||||||||||||||
12 | _MDC_PUMP_NOT_DELIVERING_REASON | pump-stopped-powered-off | Pump is stopped because it was powered off | ds-ip-rel_2.0 | ||||||||||||||||||||||
13 | _MDC_PUMP_NOT_DELIVERING_REASON | pump-stopped-not-specified | Pump is stopped due to an unspecified reason. | ds-ip-rel_2.0 | ||||||||||||||||||||||
14 | _MDC_PUMP_PROGRAM_COMPLETION_MODE | pump-program-completion-mode-stop | When the program has completed the pump will stop. | ds-ip-rel_2.0 | MDC_DEV_PUMP_PROGRAM_COMPLETION_MODE Programmed operation of the pump when a delivery completes (e.g., KVO). {IHE PCD Infusion Pump Work Group } | |||||||||||||||||||||
15 | _MDC_PUMP_PROGRAM_COMPLETION_MODE | pump-program-completion-mode-kvo | When the program has completed the pump will continue to deliver but at the kvo rate. | ds-ip-rel_2.0 | ||||||||||||||||||||||
16 | _MDC_PUMP_PROGRAM_COMPLETION_MODE | pump-program-completion-mode-continue | When the program has completed the pump will continue to deliver but at the same programmed rate. | ds-ip-rel_2.0 | ||||||||||||||||||||||
17 | _MDC_PUMP_PROGRAM_DELIVERY_MODE | pump-program-delivery-mode-continuous | The programmed delivery mode for the infusion is a single rate for the duration of the program. The programmed mode could be continuous or intermittent. | ds-ip-rel_2.0 | MDC_DEV_PUMP_PROGRAM_DELIVERY_MODE | |||||||||||||||||||||
18 | _MDC_PUMP_PROGRAM_DELIVERY_MODE | pump-program-delivery-mode-ramp-taper | The programmed delivery mode for the infusion is ramp-taper. This a specific type of multi-step where the platteau rate and time period are defined and the pump calculates the duration of each step on the ramp up to and taper down from the plateau. | ds-ip-rel_2.0 | ||||||||||||||||||||||
19 | _MDC_PUMP_PROGRAM_DELIVERY_MODE | pump-program-delivery-mode-multi-step | The programmed delivery mode for the infusion is multi-step, where the rate transitions to another rate after a period of time. There may be multiple steps defined, including a loading dose. | ds-ip-rel_2.0 | ||||||||||||||||||||||
20 | _MDC_PUMP_PROGRAM_DELIVERY_MODE | pump-program-delivery-mode-multi-dosing | The programmed delivery mode for the infusion is multi-dosing, is where the same dose is repeatedly administered from the same container at a fixed interval. There may or may not be infusion activity between the doses. | ds-ip-rel_2.0 | ||||||||||||||||||||||
21 | _MDC_PUMP_PROGRAM_STATUS | pump-program-status-not-started | The infusion pump is programmed but has not yet started the fluid delivery to the patient. | ds-ip-rel_2.0 | MDC_DEV_PUMP_PROGRAM_STATUS | |||||||||||||||||||||
22 | _MDC_PUMP_PROGRAM_STATUS | pump-program-status-active | The infusion pump is programmed and is actively delivering the fluid to the patient. | ds-ip-rel_2.0 | ||||||||||||||||||||||
23 | _MDC_PUMP_PROGRAM_STATUS | pump-program-status-complete | The infusion pump has completed delivery of the fluid to the patient. | ds-ip-rel_2.0 | ||||||||||||||||||||||
24 | _MDC_PUMP_SOURCE_INFO | pump-source-info-primary | The infusion pump is delivering a standard drug dose from the primary reservior. | ds-ip-rel_2.0 | MDC_DEV_PUMP_ENABLED_SOURCES, MDC_DEV_PUMP_ACTIVE_SOURCES | |||||||||||||||||||||
25 | _MDC_PUMP_SOURCE_INFO | pump-source-info-secondary | The infusion pump is delivering a standard drug dose from the secondary reservior. | ds-ip-rel_2.0 | ||||||||||||||||||||||
26 | _MDC_PUMP_SOURCE_INFO | pump-source-info-pca | The infusion pump is delivering a patient-initiated bolus drug dosing (e.g., PCA/PCEA) | ds-ip-rel_2.0 | ||||||||||||||||||||||
27 | _MDC_PUMP_SOURCE_INFO | pump-source-info-loading | The infusion pump is delivering a loading drug dose. | ds-ip-rel_2.0 | ||||||||||||||||||||||
28 | _MDC_PUMP_SOURCE_INFO | pump-source-info-clinician | The infusion pump is delivering a clinician initiated bolus drug dose | ds-ip-rel_2.0 | ||||||||||||||||||||||
29 | _MDC_PUMP_SOURCE_INFO | pump-source-info-intermittent | The infusion pump is delivering a programmed bolus drug dose | ds-ip-rel_2.0 | ||||||||||||||||||||||
30 | _MDC_PUMP_STAT | pump-status-infusing | The infusion pump mechanism is active. | ds-ip-rel_2.0 | MDC_PUMP_INFUSING_STATUS | |||||||||||||||||||||
31 | _MDC_PCA_LOCKOUT_STATUS | pca-lockout-dose-limit | The PCA dose-limit lockout is in effect because the maximum cumulative amount of drug that can be administered in a period of time has been reached. | |||||||||||||||||||||||
32 | _MDC_PCA_LOCKOUT_STATUS | pca-lockout-not-specified | The pump is locked out of administering additional doses due to an unspecified reason. | |||||||||||||||||||||||
33 | _MDC_PCA_LOCKOUT_STATUS | pca-lockout-none | The pump is not locked out of administering additional doses. | |||||||||||||||||||||||
34 | New enums | |||||||||||||||||||||||||
35 | _MDC_PUMP_DELIV_STAT | pump-delivery-status-priming | The pump is currently priming the fluid line. Though it is moving fluid, it is not intended to be delivered to the patient, but rather to fill the line, purge air, etc. | ds-ip-rel_2.0 | new enum for group 8 | |||||||||||||||||||||
36 | _MDC_PUMP_NOT_DELIVERING_REASON | pump-stopped-flushing | Pump is stopped because it completed the flush or was stopped during the flush. | ds-ip-rel_2.0 | new enum for group 8 | |||||||||||||||||||||
37 | _MDC_PUMP_NOT_DELIVERING_REASON | pump-stopped-switching-device | The pump is stopped while transitioning between devices during a relay. | new enum for group 8 | ||||||||||||||||||||||
38 | _MDC_PUMP_PROGRAM_STATUS | pump-program-status-paused | The infusion pump is programmed and was started but is not currently actively delivering the fluid to the patient. | new enum for group 8 | ||||||||||||||||||||||
39 | _MDC_PUMP_PROGRAM_STATUS | pump-program-status-not-programmed | The infusion pump is not completely programmed. | new enum for group 8 | ||||||||||||||||||||||
40 | _MDC_PUMP_SOURCE_INFO | pump-source-info-priming | The infusion pump is currently priming the fluid line. This fluid is not intended to be delivered to the patient, but rather to fill the line, purge air, etc. | new enum for group 8 | ||||||||||||||||||||||
41 | _MDC_PCA_LOCKOUT_STATUS | pca-lockout-patient-dose-interval | The PCA patient-dose lockout is in effect because the minimum amount of time that must pass after the last patient dose has been reached. | MDC_PCA_LIMIT_LOCKOUT_STATUS | new enum for group 9 | |||||||||||||||||||||
42 | _MDC_PCA_LOCKOUT_STATUS | pca-lockout-max-patient-doses | Patient has received the maximum number of allowable doses in the time period and is locked out from receiving more doses until the time period has expired | new enum for group 10 | ||||||||||||||||||||||
43 | _MDC_INFUS_ORDER_TYPE | clinician-dose | An infusion order type for a bolus dose in addition to the base infusion that is initiated by a clinician. | new enum for group 8, used in TF vol 2 section 3.3.4.4.10.2 Bolus from existing infusion | ||||||||||||||||||||||
44 | _MDC_INFUS_ORDER_TYPE | loading-dose | An infusion order type for a bolus in addition to the base infusion initiated prior to the start of the base infusion. | new enum for group 8, used in TF vol 2 section 3.3.4.4.10.2 Bolus from existing infusion | ||||||||||||||||||||||
45 | _MDC_INFUS_ORDER_TYPE | continuous | An infusion order type for the base infusion where the fluid or medication is administered at a consistent rate. | new enum for group 8, used in TF vol 2 section 3.3.4.4.10.2 Bolus from existing infusion | ||||||||||||||||||||||
46 | _MDC_INFUS_ORDER_STEP_TYPE | loading-dose | An infusion order step initiated prior to a continuous step. | new enum for group 8, used in TF vol 2 section3.3.4.4.10.3 Multistep | ||||||||||||||||||||||
47 | _MDC_INFUS_ORDER_STEP_TYPE | continuous | An infusion order step where the fluid or medication is administered at a consistent rate for the duration of the infusion step. | new enum for group 8, used in TF vol 2 section3.3.4.4.10.3 Multistep | ||||||||||||||||||||||
48 | Enums that can/should be deprecated | |||||||||||||||||||||||||
49 | _MDC_PCA_LOCKOUT_STATUS | pca-lockout-patient-dose | Deprecated, see pca-lockout-patient-dose-interval | MDC_PCA_LIMIT_LOCKOUT_STATUS | ||||||||||||||||||||||
50 | _MDC_PUMP_MODE | pump-mode-multi-step | 4 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
51 | _MDC_PUMP_MODE | pump-mode-multi-dosing | 8 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
52 | _MDC_PUMP_MODE | pump-mode-ramp-taper | 9 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
53 | _MDC_PUMP_MODE | pump-mode-patient-dose | 10 | The infusion pump is programmed to allow patient-initiated drug dosing (e.g., PCA). Replaced pump-mode-pca that has the same value. | Deprecated 10MAY21, add code for "not in use" | |||||||||||||||||||||
54 | _MDC_PUMP_MODE | pump-mode-loading-dose | 14 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
55 | _MDC_PUMP_MODE | pump-mode-continuous | 15 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
56 | _MDC_PUMP_MODE | pump-mode-piggyback | 16 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
57 | _MDC_PUMP_MODE | pump-mode-clinician-dose | 17 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
58 | _MDC_PUMP_MODE | pump-mode-kvo | 18 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
59 | _MDC_PUMP_MODE | pump-mode-flushing | 19 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
60 | _MDC_PUMP_MODE | pump-mode-concurrent | 20 | Deprecated 10MAY21, add code for "not in use" | ||||||||||||||||||||||
61 | _MDC_PUMP_MODE | pump-mode-priming | 21 | The pump is currently priming the fluid line. Though it is moving fluid, it is not intended to be delivered to the patient, but rather to fill the line, purge air, etc. | Deprecated 10MAY21, add code for "not in use" | |||||||||||||||||||||
62 | _MDC_PUMP_MODE | pump-mode-other | 22 | The pump is programmed in an operational mode that does not match one of the defined modes. | Deprecated 10MAY21, add code for "not in use" | |||||||||||||||||||||
63 | _MDC_PUMP_SOURCE_INFO | pump-source-info-secondary-piggyback | This term is not needed, can be withdrawn 10MAY21 | |||||||||||||||||||||||
64 | ||||||||||||||||||||||||||
65 | ||||||||||||||||||||||||||
66 | ||||||||||||||||||||||||||
67 | ||||||||||||||||||||||||||
68 | ||||||||||||||||||||||||||
69 | Red text is new or changed | |||||||||||||||||||||||||
70 | Yellow highlight has been reviewed by WG | |||||||||||||||||||||||||
71 | Existing descriptions are in black text | |||||||||||||||||||||||||
72 | ||||||||||||||||||||||||||
73 | ||||||||||||||||||||||||||
74 | ||||||||||||||||||||||||||
75 | ||||||||||||||||||||||||||
76 | ||||||||||||||||||||||||||
77 | ||||||||||||||||||||||||||
78 | ||||||||||||||||||||||||||
79 | ||||||||||||||||||||||||||
80 | ||||||||||||||||||||||||||
81 | ||||||||||||||||||||||||||
82 | ||||||||||||||||||||||||||
83 | ||||||||||||||||||||||||||
84 | ||||||||||||||||||||||||||
85 | ||||||||||||||||||||||||||
86 | ||||||||||||||||||||||||||
87 | ||||||||||||||||||||||||||
88 | ||||||||||||||||||||||||||
89 | ||||||||||||||||||||||||||
90 | ||||||||||||||||||||||||||
91 | ||||||||||||||||||||||||||
92 | ||||||||||||||||||||||||||
93 | ||||||||||||||||||||||||||
94 | ||||||||||||||||||||||||||
95 | ||||||||||||||||||||||||||
96 | ||||||||||||||||||||||||||
97 | ||||||||||||||||||||||||||
98 | ||||||||||||||||||||||||||
99 | ||||||||||||||||||||||||||
100 |