Originator (First & Last Name):Chit CodeComment/Concern/Recommendation:
Review Board Comment:
Review Board Recommendation:
2
StefanIPFCFPTREADIPR01Please ground the metal parts of the slings and flanges with a resistance that is consistent with proper function of the FCPC GF monitors (likely not a hard short to ground).
pick proper resistance for grounding
concur
3
LoesserIPFCFPTREADIPR02Do not support coils at mounting (3) locations strictly on diving boards of slings
work on the G10 plate adjustment
concur
4
StefanIPFCFPTREADIPR03The flux loop wires will have a voltage on their terminals up to 2000 V / 64 turns = 31 V. While not a safety issue to people due to the restricted access, please verify that these have an appropriate open circuit configuration so that we do not induce damaging currents.
concur
5
stefan gerhardtIPFCFPTREADIPR04It is important that the cooling water entrance and exit be correctly configured relative to the inner and outer layers. I'll not specify it here, but please make sure it is clear in the procedures.concur
6
Andres CastanedaIPFCFPTREADIPR05The calculation related to the master spreadsheet is slated for revision due to an identified error. When revising the calculation, please consider verifying the master spreadsheet against the revised calculation, and then locking any cells that are determined to be static (formulae, constants, etc...) against inadvertent changes. Consider making the spreadsheet an attachment to the calculation so that it benefits from revision control.concur
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100