IntelliCenter API
 Share
The version of the browser you are using is no longer supported. Please upgrade to a supported browser.Dismiss

View only
 
ABCDEFGHIJKLM
1
2
Command Syntax - Substiute 'OOO', 'PPP' and 'VVV' with values from the tables below
3
{"command":"SETPARAMLIST","objectList":[{"objnam":"OOO","params":{"PPP":"VVV"}}],"messageID":"foobar"}
4
5
objnamNotes
(Replace 'x' with the number of the applicable item with leading zero(s) where required)
6
C00xxCircuit AKA Relay (With or without light attached)
7
GRPxxCircuit Group
8
FTRxxFeature
I can't see a way to conrol valves (VALxx) directly, ?????????
9
p01xx
p02xx
p03xx
Pump (Select the correct prefix based on your pump type (VS, VF, VSF)
p01xx - VS
p02xx - VF
p03xx - VSF
10
B1101
B1202
Body of Water
B1101 - Pool
B1202 - Spa
Not sure if this naming is universal to all systems, check your setup to see if it matches.
Heaters are 'affiliated' with pool, spa or pool & spa bodies of water so when adjusting a heater you must address it via a body of water to which it is affliated.
11
CHMxxIntelliChem
12
CHRxxIntelliChlor
13
REMxxSpa-side Remote
14
15
16
Property Name (PPP)See chart above for correct format of 'objnam' value (OOO)
17
Property Value (VVV)CircuitCircuit
(with light attached)
GroupGroup
(with light members)
FeaturePumpBody of WaterBody of Water
(with affiliated Heater)
IntelliChemIntelliChlorSpa-side RemoteNotes
18
STATUSON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Pump - ON will turn on the pump to the previous GPM or RPM the pump was set to when it was last turned off
19
ENABLEON
OFF
ON
OFF
20
ACTSAMMOD
PARTY
ROMAN
CARIB
AMERCA
SSET
ROYAL
BLUER
GREENR
REDR
WHITER
MAGNTAR
SAMMOD
PARTY
ROMAN
CARIB
AMERCA
SSET
ROYAL
BLUER
GREENR
REDR
WHITER
MAGNTAR
Circuit (with light attached) - After sending ACT command, must send STATUS:ON to activate
Circuit (with light attached) - ACT only applies to Colour lights
21
LIMIT[Numeric value as string. e.g. "50"][Numeric value as string. e.g. "50"]Circuit (with light attached) - LIMIT only applies to White lights to set the brightness, STATUS:ON is not required to activate
22
SELECTRPM
GPM
Pump - Only applicable to VSF pumps to set the value (GPM or RMP) that is implied by and subsiquent SPEED commands
23
SPEED[Numeric value as string. e.g. "3450"]
24
PHSET[Numeric value as string. e.g. "123"]
25
ORPSET[Numeric value as string. e.g. "123"]
26
ALK[Numeric value as string. e.g. "123"]IntelliChem - I am not sure what this is for
27
CALC[Numeric value as string. e.g. "123"]IntelliChem - I am not sure what this is for
28
CYACID[Numeric value as string. e.g. "123"]IntelliChem - I am not sure what this is for
29
PRIM[Numeric value as string. e.g. "123"]IntelliChlor - Set chlorine generation intensity (%)
30
SUPERON
OFF
IntelliChlor - Turn ON/OFF 'Super Chlorinate'
31
HEATER00000
H0001
H0002
H0003
HXSLR
HXULT
Body of Water (With Heater affiliated) -
00000 - Heating/Cooling Off
H0001 - Gas Heater Only On
H0002 - UltraTemp Only On
H0003 - Solar Only On
HXULT - UltraTemp Preferred
HXSLR - Solar Preferred
32
LOTMP[Numeric value as string. e.g. "28"]Body of Water (With Heater affiliated) - Sets the deired temperature to HEAT to
33
HITMP[Numeric value as string. e.g. "25"]Body of Water (With Heater affiliated) - Sets the deired temperature to COOL to
(Only applicable to UltraTemp)
34
SWIMON
35
SYNCON
36
SETON
37
38
Setting Body of Water state
39
Command syntax is different from all other commands discovered so far.
Only one BoW may be 'ON' at any time. Changing STATUS to ON on a given BoW will set STATUS of all other BoWs to OFF automatically.
Replace BBB with the Body of Water to be adjusted. reffere to table at top for BoW syntax.
Replace VVV with the desired state, valid values are ON/OFF
40
{"command":"SETCOMMAND","method":"SETBODYSTATE","arguments":{"BBB":"VVV"},"messageID":"foobar"}
41