temp test
 Share
The version of the browser you are using is no longer supported. Please upgrade to a supported browser.Dismiss

 
View only
 
 
Still loading...
ABCDEFGHI
1
2
3
TimeBaffle endTemp CenterFireboxDifference
4
5
Fired up Log Lighter and added 3 large logs, Door open, all 4 valves open
6
7
5108125 F102-6
8
7117130109-8
9
10123145116-7
10
0
11
Closed door, Log Lighter still on, top ok to touch
12
13
12137165128-9
14
15150180140-10
15
18164200151-13
16
20184230168-16
17
25220275194-26
18
28250300215-35
19
Turned off Log Lighter, top of Firebox too hot to touch
20
21
30254280220-34
22
35281310239-42
23
Opened smoke chamber door 10 seconds
24
0
25
36235280230-5
26
37275290239-36
27
41288300251-37
28
45289295258-31
29
50286295265-21
30
Added 1 small split
31
32
55300323278-22
33
60323355298-25
34
Closed 2 Valves
35
36
65317330303-14
37
703123253120
38
803163253215
39
8531532532914
40
9031632533620
41
9531332034027
42
10031031534232
43
Opened Smoke chamber lid 15 seconds
44
0
45
10427329033562
46
10529129033847
47
Opened Fire Box Door
48
49
11030632534135
50
11530131033837
51
12029730533538
52
12528930033041
53
13028127532544
54
13527527531843
55
14026626031145
56
15025826030345
57
Opened smoke chamber Lid 20 seconds
58
59
15222023029373
60
15325525029742
61
16025325029340
62
16524524028641
63
Opened firebox door and Stoked Fire.
64
65
16724123028342
66
17023823027840
67
17523122527039
68
18022622525832
69
Added a small split
70
71
18322622025933
72
18522622525832
73
19022622525428
74
19522522525126
75
Opened 3rd valve
76
77
19723022525222
78
20023122525221
79
20523323025219
80
Opened Smoke Chamber Lid 5 seconds
81
82
20723123025221
83
21023323025219
84
21522722025023
85
22022221024826
86
Added a small split
87
88
22222422024824
89
22522622524822
90
22820422024339
91
23022522524722
92
23522322524522
93
Opened Smoke Chamber lid 15 seconds
94
95
23719721524043
96
24022121524221
97
24521722024023
98
Added a small split
99
100
25021621023923
Loading...
 
 
 