4.21 - Exposure of i-line OiR906-12 (1.2 μm and 2.8 μm) on ksaligner
5
6
Description:This monitor tracks i-line OiR906-12 resist performance on ksaligner for 1.2 μm and 2.8 μm resist thicknesses. This monitor includes: 1) 1.2 μm i-line dose to clear, 2) 2.8 μm i-line dose to clearOutput Response
7
ResponseDescriptionTargetUSLLSL
8
Tool:Ksaligner1.2 μm Dose (mJ/cm²)Characterize best exposure time for the 1.2 μm samples and use that to calculate the required dose. Check the wafer for smallest resolved feature. The wafer with the smallest well-resolved features is chosen for the best exposure time. Exposure dose is calculated using the equation (ExposureTime)*(LampIntensity)=Dose.407010
9
Resist and Developer:OiR906-12 i-line photoresist and MF26A developer
10
Mask:"Elbows Monitor" (Clearfield)
11
Up-stream:Starting wafer is bare Si2.8 μm Dose (mJ/cm²)Characterize best exposure time for the 2.8 μm samples and use that to calculate the required dose. Check the wafer for smallest resolved feature. The wafer with the smallest well-resolved features is chosen for the best exposure time. Exposure dose is calculated using the equation (ExposureTime)*(LampIntensity)=Dose.10014060
12
If new silicon wafer: clean in MSINK6 Piranha (10 minutes), MSINK6 HF (1 min)
13
If stripping old litho wafer: clean in MSINK1 1165 (10 minutes), MSINK8 Pirahnha (10 minutes), MSINK8 HF (1 min)
14
Down-stream:Patterned wafer is inspected and then retired (stripped and rerun)
15
16
Tool SpecificationsProcess Performance
17
StepToolSettings - 1.2 μm ProcessSettings - 2.8 μm Process
18
4.21.1 - Prime/Coat/Soft Bake(svgcoat6)Flow: 01_OIR1.2um_Bake60s90CFlow: 01_OIR2.8um_Bake60s90C
19
VP: HMDS_60sVP: HMDS_60s
20
CHILL1: Cool_6sCHILL1: Cool_6s
21
SMC: OIR906_1.2umSMC: OIR906_2.8um
22
HPO: Bake60s90CHPO: Bake60s90C
23
CHILL2: Cool_6sCHILL2: Cool_6s
24
4.21.2 - Expose(ksaligner)Check lamp intensity with the G&R Labs Intensity Meter using a 5-point measurement at 5 cm intervals. More lamp intensity information is included in the ksaligner Lamp Intensity Process Specification. Compare meter reading to power supply reading and check the uniformity. Expose wafers in hard contact mode. Run one wafer per exposure time, 2 seconds apart.
25
26
4.21.3 - Develop(svgdev6)Flow: 01_PEB120C60s_MF26A60s
27
HPO1: Bake60s120C
28
CHILL1: Chill_5s
29
MDTD: MF26A_Puddle60s
30
HPO2: HPO2_Bypass
31
CHILL2: No Chill
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Loading...
Main menu