ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
2
Standard Method Dwelling Unit Load CalculationsOptional Dwelling Unit Load CalculationsExisting Optional Dwelling Unit Load Calculations
3
Lighting & Receptacles, 220.42ServiceNeutralServiceService
4
General Lighting 4,000 3 12,000 General Lighting 12,000 General Lighting 12,000
5
Small Appliance 1,500 2 3,000 Small Appliance 3,000 Small Appliance 3,000
6
Laundry 1,500 1 1,500 Laundry 1,500 Laundry 1,500
7
Total Connected Load 16,500 Dishwasher 1,200 Dishwasher 1,200
8
First 3,000 VA at 100%
3,000 100% 3,000 3,000 Waste Disposal 600 Waste Disposal 600
9
Remainder VA at 35% 13,500 35% 4,725 4,725 Microwave 1,600 Microwave 1,600
10
Total 7,725 7,725 Water Heater 30,720 Water Heater 30,720
11
Appliances, 220.53ServiceNeutralCar Charger - Car Charger
12
Dishwasher 1,200 1 1,200 75% 900 900 Other Appliances - Other Appliances
13
Waste Disposal 600 1 600 75% 450 450 Other Appliances - Other Appliances
14
Microwave 1,600 1 1,600 75% 1,200 1,200 Dryer 5,000 Dryer 5,000
15
Water Heater 30,720 1 30,720 75% 23,040 Cooking Nameplate 14,000 Cooking Nameplate 14,000
16
Car Charger1 - 75% - Cooking Column BCooking Column B
17
Other Appliances - 75% - Cooking Column ACooking Column A
18
Other Appliances - 75% - 69,620 69,620 69,620
19
Total 34,120 75% 25,590 2,550 First 10kW @100%10000100% 10,000 First 8 kW at 100%8000100%8000
20
Dryer, 220.54ServiceNeutral
Remainder kW at 40%
59,620 40% 23,848 Remainder kW at 40% 61,620 40%24648
21
Dryer 5,000 1 5,000 100% 5,000 3,500 Heat, up to 4 units - 65% - Heat at 100% - 100%0
22
ServiceNeutralHeat, over 4 units - 40% - Heat, Over 4 Unit - 40% -
23
Range #1, Column C1400018800100% 8,800 6,160 A/C or Heat Pump 10,000 100% 10,000 A/C or Heat Pump 10,000 100% 10,000
24
Range #2, Column C0100% - - Total Demand Volt-Amperes 43,848 Total Demand Volt-Amperes 42,648
25
Cooktop, Column B080% - - Total Demand Amperes183Total Demand Amperes178
26
Oven, Column A080% - - Service Equipment Amperes200Service Equipment Amperes200
27
Total 8,800 6,160 Conductor Amperes at 83%166Conductor Amperes at 83%166
28
Heat versus A/CServiceNeutralConductor Size2/0Conductor Size2/0
29
A/C #1100001 10,000 10,000 Conductor Ampacity, Table 310.15(B)(16)175Conductor Ampacity, Table 310.15(B)(16)175
30
Heat #11 - 0
31
Heat Pump #1 - -
32
A/ C #2 - - -
33
Heat #2 - -
34
Heat Pump #2 - -
35
36
Standard Method Dwelling Unit Load Calculations
37
ServiceNeutral
38
Lighting and Receptacles 7,725 7,725
39
Appliances 25,590 2,550
40
Dryers 5,000 3,500
41
Cooking Equipment 8,800 6,160 This Table is for Formulas Only
42
A/C versus Heat 10,000
43
ChargerCuSizeAL
44
Total Demand Volt-Amperes 57,115 19,935 211025
45
Total Demand Amperes2388331840
46
Service Equipment in Amperes25051650
47
Conductor Amperes at 83% of Service Equipment Size2088366465
48
Conductor Size4/0486375
49
Conductor Ampacity, Table 310.15(B)(16)23085101290
50
1161100
51
Neutral Conductor Must Be Sized No Smaller Than 250.66
1311/0120
52
1512/0135
53
1763/0155
54
2014/0180
55
231250205
56
256300230
57
286350250
58
311400270
59
60
SizeCuAL
61
103025
62
85040
63
66550
64
48565
65
39075
66
211590
67
1130100
68
1/0150120
69
2/0175135
70
3/0200155
71
4/0230180
72
250255205
73
300285230
74
350310250
75
400335270
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100