ABCDEFGHIJKLMNOPQRSTUVWXYZAAABACADAEAFAGAH
1
DeviceLog DateLog TimeVersion ObservationsOccur DateOccur TimeStep 1 - Voltage check3.3V CheckStep 2 - STATUS PINStep 3 - TEST POWER KEYStep 4 - Test SIM7000 RXStep 5 - Test SIM7000 TXStep 6 - Test BoSL TXStep 8 - ResetStep 7 - Reset SIM7000Step 9 - reconnect batteryStep 10 - other actionsOutcome after actionNoteOutcomeCategory
2
10 QLD and 10 NEW31/05/202315:30:00NANAsetupNA
3
NEW_931/05/202315:40:00Not show on the web31/05/202315:30no action takenno action taken, to see whether it just simply take longer to initiateUnknown
4
NEW_901/06/202312:00:00Still not show on web31/05/202315:30swapped sim card for NEW_6 and NEW_9 / just swap the sim cards for a quick trial without specific reasonsstart updating on webconfused, why swaping sim card can fix then?Unknown
5
NEW_601/06/202312:00:00Stop updating on web31/05/202321:45swapped sim card for NEW_6 and NEW_9 / just swap the sim cards for a quick trial without specific reasonsstart updating on webconfused, why swaping sim card can fix then?Unknown
6
All 10 OLD02/06/202311:30:00All goodAll goodchanged simOff delay from 1100ms to 1200msNA
7
OLD_106/06/202313:24:00Stop updating on web03/06/202320:51reset OLD_1Reset not workingNo further action taken to OLD_1Unknown
8
OLD_107/06/202314:26:00Still not updating on web03/06/202320:51
replaced a new battery for OLD_1
start updating on webUnknown
9
OLD_307/06/202314:29:00Stop updating on web07/06/202313:33reset OLD_3Reset not workingUnknown
10
OLD_307/06/202314:57:00Still not updating on web07/06/202313:33reconnect battery for OLD_3start updating on webUnknown
11
NEW_207/06/202317:00:00Stop updating on web07/06/202307:08reset NEW_2Reset not workingUnknown
12
NEW_207/06/202317:07:00Stop updating on web07/06/202307:08reconnect battery for NEW_2start updating on webUnknown
13
NEW_508/06/202311:16:00Stop updating on web08/06/202310:47connected NEW_5 to PC USB(Vitrual Serial)start updating on webWhy connecting to usb fixed it?Unknown
14
NEW_114/06/202313:00NEWStop updating on web13/06/202313:28:003.847 Vforever 5.7 - 5.8 mValmost always stay at 1.3V;
the board tried to pull it low to 0V multiple times;
but all went back to 1.3V and stay there forever;
it did went to 0.8V but only for a short period of time before it went back to 1.3V again
TX files at NEW_1_TX_TEST sheetreconnect batterystart updating on webIssue with sim7000 communication. replugging battery solved issue. No issue with AT MEGASIM7000 Issue
15
OLD_215/06/202314:00OLDStop updating on web14/06/202323:58:073.984Valways 0Valways 0.47-0.48Vno output for the 9-min testing period (14:18 - 14:27)reset sim7000 for OLD_2start updating on webReconnect battery to make it back logging again, the battery level before reconnect was < 2VATMega issue, then 1.8V issue; reconnecting battery to restore normal logging1.8V Issue
16
OLD_X, OLD_11, OLD_12, OLD_13, OLD_14, NEW_0, NEW_11, NEW_12, NEW_13, NEW_1417/06/202319:56Set up more bosl boardsN/AN/A
17
OLD_X19/06/202310:22OLDStop updating on web17/06/202313:573.91Valways 0Valways 0.79 - 080Vno output for 30minutesno output for 18 minutesReconnect battery to make it back logging again, the battery level before reconnect was < 2VATMega issue, then 1.8V issue; reconnecting battery to restore normal logging1.8V Issue
18
NEW_baudrate20/06/202317:30NEWSet up a NEW bosl, simcom baudrate=38400N/AN/A
19
NEW_1320/06/202311:50NEWStop updating on web20/06/202309:573.9VChanging normal, 1.35V, 0.8V, 0Vhttps://drive.google.com/file/d/15EKVVJJV-xyQ3okWQ3yFcUOeLY5BlRcl/view?usp=drive_linkno outputreset sim7000start updating on webissue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
20
NEW_120/06/202313:20NEWStop updating on web20/06/202312:484.01Valways 0V for 10 minutesalways 1.335V-1.336V for 10 minuteshttps://drive.google.com/file/d/1NtgAlngJvWctDjc9HCFtAQlN7rng-FaC/view?usp=drive_linkno outputreset sim7000start updating on webissue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
21
BoSL_logging_delay_480s21/06/202311:00OLDStop updating on web21/06/202308:303.894V2.5XXV, 0V for 1 or 2 seconds0VWhen connect GND and simcom TX to passthrough uno, and test simcom TX, see OK in the serial monitor, check web page and see it start to log, status pin voltage changed to 0VUnsure what happened.Self-recovery
22
NEW_14, NEW_13, OLD_14, OLD_1321/06/202310:31Change simcom baudrate to 38400N/AN/A
23
OLD_122/06/202310:38OLDStop updating on web22/06/202306:373.941Valways 0Vchanges normally, 1.33xV, 0.80V, 0.4xV, 0Vhttps://drive.google.com/file/d/1_BUmJmVQXiIdRw7Zch3_qa_pMcoRHAAH/view?usp=drive_linkno outputreset sim7000start updating on webissue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
24
OLD_922/06/202304:30OLDStop updating on web22/06/202313:433.883V0V or 0.005V for 10 minuteschanges normally, 1.33xV, 0.79V, 0.4xV, 0Vhttps://drive.google.com/file/d/1TbT-Q0SQwuUKGmG_yfFHXtv4bUxjiHco/view?usp=drive_linkno outputreset sim7000start updating on webissue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
25
OLD_823/06/202310:00OLDStop updating on web23/06/202305:363.854V0V for 10 minuteschanges normally, 1.3xxV, 0.799V, 0.404V, 0Vhttps://drive.google.com/file/d/18dey1i4oohH6mSY0hWQ584pZVO75hY1f/view?usp=drive_linkno outputreset sim7000start updating on webissue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
26
BoSL_logging_delay_600s26/06/202310:11OLDStop updating on web25/06/202311:493.719Valways 2.608V, 2.596V - 2.4xxVaways 0.005Vno outputreset ATMEGA 7 times about every 30 secondsafter several reset tries not work. left it there for 10 minutes and it started to work again.....start updating on webReset not work for BoSL ATMEGA, test Atmega reset pin(29) voltage(3.03V), when button pushed down, voltage pulled down to 0 perfectly, but atmega won't wake up.Test VCC pin(4) and AVCC pin(18), all 3.308V, GND Pin(3) 0VATMEGA issue; reconnecting battery to restore normal loggingATMEGA Issue
27
NEW_227/06/202310:03NEWStop updating on web27/06/202302:453.728Valways 0.005Vchanges, 1.33V, 0.81V, 0.4V, 0V, but pulls up powerkey at 1.33V too long time, more than 8 minutesno outputno outputno outputreset ATMEGA 3 or 4 timesreset sim7000start updating on web
on first 3 resets for atmega, power pin voltage changes, but no output from BoSL TX.The last time, power pin changes and BoSL TX starts to print.
issue with sim7000 communication. resetting atmega and simcom7000 solved issue. ATMEGA not totally dead, but works not well. stay at 1.34V too long and no commands sent to Sim7000 in the testSIM7000 IssueI am not sure about whether AT MEGA is an issue. please explain this more.
28
OLD_1027/06/202311:14OLDStop updating on web26/06/202308:123.783Vaways 0.000Valways 0Vhttps://drive.google.com/file/d/1969anHUZQqScWKTw8U1is1uZMB4CW6r9/view?usp=drive_linkhttps://drive.google.com/file/d/1yBQoeS9nxm9hQY_I_oxcXWEyDHzN5j7D/view?usp=drive_linkreset sim7000start updating on webissue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
29
OLD_1427/06/202312:09OLDStop updating on web24/06/202307:083.851Valways 0.000Vchanges, 1.33V, 0.81V, 0.4V, 0Voutput strange characters
https://drive.google.com/file/d/1ymS-ojtsFTM0P5UCOQtp2T_3Aq3-9EM9/view?usp=drive_link
no outputhttps://drive.google.com/file/d/1I7bz-gjGd_mFTiBxidzJAm2mOLZq78Ot/view?usp=drive_linkstart updating on webNo reset done to BoSL or SIM7000, OLD_14 start to log during the testsim7000 not respond to powerkey voltage change. ATMEGA sending strange characters to sim7000. BoSL TX prints good logSIM7000 Issue*** this issue about characters is because you changed the baud rate. in future tesing, be sure to change the baud rate of your measurment method. yes, thanks
30
OLD_1428/06/202310:00OLDStop updating on web27/06/202315:073.791Valways 0Vchanges, 1.34xV, 0.81V, 0.404V, 0Vstrange characters
https://drive.google.com/file/d/1CeRVSwuwvMw8R9ob1NoC5JBNm5I9X_Eo/view?usp=drive_link
no outputhttps://drive.google.com/file/d/1825Hyt94XohSSgzRotzmW4vVvCCiNRGQ/view?usp=drive_linkreset sim7000start updating on websim7000 not respond to powerkey voltage change. ATMEGA sending strange characters to sim7000. BoSL TX prints good logSIM7000 Issue*** this issue about characters is because you changed the baud rate. in future tesing, be sure to change the baud rate of your measurment method.
31
NEW_703/07/202304:30NEWStop updating on web01/07/202308:263.609Valways 0V1.35Xv, 0v, 0.80xVhttps://drive.google.com/file/d/14rmJejBa3_MSAqGPz50DUwNDy9c-7pUB/view?usp=drive_linkno outputstart updating on webno reset or other actions, just testing powerkey and sim RX, then it started to logUnknown, BoSL started to log during the test.Self-recovery
32
NEW_1403/07/202302:17NEWStop updating on web30/06/202323:203.695Valways 0V1.3xV, 0.79V, 0Vhttps://drive.google.com/file/d/15b1tIqD4ajujhFt53x0GkEZR13pL-gXZ/view?usp=drive_linkno outputhttps://drive.google.com/file/d/1L5WpcBFefjg419fqE9z8WVYDWauzMxme/view?usp=drive_linkreset sim7000start updating on websim7000 not respond to powerkey voltage change. SIM RX reads good log from ATMEGA.
BoSL TX prints good log
SIM7000 Issue
33
BoSL_logging_delay_600s03/07/202312:04OLDStop updating on web02/07/202315:073.601Vaways 1.798Valways 0.789V~0.804V for 10 minutes.
start to changes normally after about 20 minutes
no output for 10 minutes, then started to log after about 20 minutes.no output for 10 minutesno reset, no other actions, just testing, bosl started to log.start updating on webLooks like ATMega issue at first. But BoSL starts to logging during the test.
No reset or other actions taken.
Self-recovery
34
OLD_103/07/202301:58OLDStop updating on web01/07/202304:023.665V2.5xxV, 0V0.799Vyes, output can be seen in BoSL TX loghttps://drive.google.com/file/d/1RwCPZIXpQSP6dqHmyKLOl0x2GWHjkYoC/view?usp=drive_linkreset sim7000start updating on webSIM7000 issue. Sim7000 status pin voltage is very high(2.5xV). Sim7000 response to atcommands.
But from the log, it shows Http action fails(error code: 604).
Stack Busy
35
BoSL_logging_delay_480s03/07/202310:26OLDStop updating on web02/07/202311:063.607V2.598V when ATmega in low power mode
2.4xxV when ATmega wake up
1.408V when ATMega is in lowpower mode.
0V for 1 second and 1.2xxV to 1.3xxV for seconds when ATmega is running
https://drive.google.com/file/d/1Whq-DnAmLKJwQN7Pu6P8ozVannuIBQVv/view?usp=drive_linkyes, output can be seen in BoSL TX loghttps://drive.google.com/file/d/1VEMQEHc6gcDFXQgHYdlBGgGcN8o6exV7/view?usp=drive_linkreset sim7000start updating on webSIM7000 issue. Sim7000 status pin voltage is very high(2.5xV). Sim7000 response to atcommands.
But from the log, it shows Http action fails(error code: 603).
DNS error
36
NEW_904/07/202310:44NEWStop updating on web02/07/202315:072.605V, sometimes goes down to 1.8V for 1 or 2 secondsalways 0V0.789Vno outputdecide not to reset it for the momentUnknown, Voltage drops to bellow 3VUnknown
37
BoSL_logging_delay_480s06/07/202310;50OLDStop updating on web03/07/202311:063.574V2.598V1.318V - 1.4xxV, 0V, 0.808Vhttps://drive.google.com/file/d/1frs3FGuemb05pluNb0PCCvWvMlfrGk0V/view?usp=drive_linkhttps://drive.google.com/file/d/1frs3FGuemb05pluNb0PCCvWvMlfrGk0V/view?usp=drive_linkhttps://drive.google.com/file/d/1CcISSNLLVFTlTKNloFsiB4p7nAL05Ava/view?usp=drive_linkreset sim7000start updating on webSIM7000 issue. Sim7000 responses to atcommands.
But from the log, it shows Http action fails(error code: 603 or 604).
DNS error
38
NEW_507/07/202310:19NEWStop updating on web07/07/202304:323.626Valways 0V - 4.8mV0V when ATmega in low power mode.
when ATmega is runing - most of the time 1.3xxV, sometimes goes up slowly to 1.9V then quickly goes back to 1.3V.
, sometimes sudenly jump up to 2.2V then jump down to 1.3V
https://drive.google.com/file/d/1kL-bTzyBpJ-krXIbGYopqMbisFicuI1r/view?usp=drive_linkno outputhttps://drive.google.com/file/d/1CzkxAbmsRhene3IRL4YMB5XesmspQyhh/view?usp=drive_linkreset sim7000start updating on webissue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
39
openbearer07/07/202311:22OLDStop updating on web06/07/202312:023.631Valways 0V1.3V, 0V, 0.8Vhttps://drive.google.com/file/d/1oKeGSQaCkqForTKhQ7LpVvIawSdTwDhx/view?usp=drive_linkno outputhttps://drive.google.com/file/d/1ytaras8fjE2MvX0xU5InABJ1PUPKsDV4/view?usp=drive_linkreset sim7000start updating on webissue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
40
NEW_810/07/202310:24NEWStop updating on web09/07/202317:583.475Valways 0Valways 0.014V - 0.017Vno outputno outputreset ATMegareconnected batterystart updating on webATMEGA issue; reconnecting battery to restore normal logging.ATMEGA Issue
41
NEW_713/07/202313:32NEWStop updating on web04/07/202310:272.646Valways 0.005Valways 0.794~0.8Vno output no outputno output reset AT Mega Replaced new battery start updating on web The battery voltage dropped to 2.646 V. When new battery replaced, the BoSL starts logging. The power is running out. Flat battery
42
NEW_913/07/202316:20NEWStop updating on web 02/07/202315:070V--------Replaced new battery start updating on web In 02/07/2023, the voltage dropped to 2.9V and no futher actions. After 11 days, the voltage is dropped 0 V. The power is running out. Flat battery
43
NEW_513/07/202313:05NEWStop updating on web 07/07/202310:551.309VInitial -0.02V; after 3-4 mins, the BoSL logging begins, Sim7000 turns on, the voltage suddenly changes to around 2.5 V. Then voltage (Vpp) back to 3.6 V.---https://drive.google.com/file/d/1t2_lcg-csatjcwJCcsuI_7CPjNOaB3Jg/view?usp=sharingno reset, no other actions, Suddently BoSL started to log during the testing the Status Pin. start updating on web Unknown reason. The BoSL suddently started to log during the testing. Unknown Self-recovery
44
NEW_413/07/202311:04NEWStop updating on web11/07/202314:393.529Valways 0.006V; when the loop ends, perfect 0. initial 0.376 V.Then, continues around 0.35~0.37V. Suddently, drop to 0V. Then, back to 0.8V. https://drive.google.com/file/d/1BbRSeZulXtWw0YIthy8EPxlI0L0J_VUC/view?usp=share_linkhttps://drive.google.com/file/d/14jjiJHEg3uMgiTLLWeef3e1MAWZ86TNE/view?usp=share_linkreset sim7000start updating on webThere is no response from sim7000. No issue with AT MEGA. SIM7000 Issue
45
OLD_313/07/202314:23OLDStop updating on web06/07/202310:213.346VInitial 0.006 V. Suddently, the voltage changes to 2.422V when loops started. When loop end, back to 0.004VInitial 0.836V. When loop starts, the voltage increases to 1.46V. When loop ends, drop back to 0.844V. https://drive.google.com/file/d/1GgJylhOOlRXKjaPKKf3Y66dv-u-FRAJe/view?usp=sharinghttps://drive.google.com/file/d/1qIvbgZ0O3CWdExWxGK_FyhooclDtxJLn/view?usp=sharinghttps://drive.google.com/file/d/1spyH5zry03mfKF_Dgqgu4VbWYkZotvPW/view?usp=sharingNo reset, no other actions. start updating on web The loop of SIM7000 TX ends with " Normal Power Down". Without reset, it start updating on web. Unknown Self-recovery
46
OLD_317/07/202314:56OLDStop updating on web 15/07/202322:400.0048V--------replaced new battery start updating on web no other actionThe power is running out. Flat battery
47
BoSL_logging_delay_480s17/07/202316:07OLDStop updating on web 14/7/202319:292.62Valways 0V---NO output---replaced new battery start updating on web no other actionThe power is running out. Flat battery
48
BoSL_logging_delay_600s17/07/202316:28OLDStop updating on web 11/7/202300:272.772V----No output---replaced new battery start updating on web no other actionThe power is running out. Flat battery
49
OLD_117/07/202313:56OLDStop updating on web 13/07/202323:553.446VInitial 0.004V. Since the loop started, the voltage changes to around 11 mV. During the loop, the voltage always 10~12mV. Initial 1.7V. When the loop starts, the voltage increases to 2.23 V. When loop ends, drop back to 1.8 V. https://drive.google.com/file/d/1aMqKOxExqQrd3F6kRfRAiiweqQ_d-DpQ/view?usp=sharingNO OUTPUThttps://drive.google.com/file/d/1Y3MDlcOZS58gXvGWMcdoxcZCLuMYNbXS/view?usp=sharingreset SIM7000--start updating on web issue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
50
OLD_X17/07/202316:43OLDStop updating on web 14/07/202312:333.533VInitial 1 mV. when the loop started, the voltage increases to 6mV~7mV. When loop finished, back to 1mV. Initial 1.26V.Sometimes, 1.95V. Suddently, the voltage drops to 0 V. Then loop starts, the voltage increases to 1.58V (constant)~1.53V. As loop ends, the voltage drops to 1.26 or 1.95Vhttps://drive.google.com/file/d/1yVNy06EknWKNMlCbedHeoOjePpFFLQ3Q/view?usp=sharingNo outputhttps://drive.google.com/file/d/12Ac2MAhPacvkJvpb7LRYitVZjEqbA-Um/view?usp=sharingreset SIM7000--start updating on web no other action issue with sim7000 communication. resetting simcom7000 solved issue. No issue with AT MEGASIM7000 Issue
51
OLD_1217/07/202315:08OLDStop updating on web 14/07/202318:423.59VInitial 0.005V. Since the loop started, the voltage changes to around 14mV. During the loop, the voltage always around 10~14 mV. When loop end, back to 0.004V. Initial 1.8V. When the loop starts, voltage increases to 2.1V~ 2.24V. When loop ends, drop back to 1.7V.~1.9V https://drive.google.com/file/d/12Ac2MAhPacvkJvpb7LRYitVZjEqbA-Um/view?usp=sharingNo outputhttps://drive.google.com/file/d/12Ac2MAhPacvkJvpb7LRYitVZjEqbA-Um/view?usp=sharingreset SIM7000--After action, there is no updating. However, on 18/7/2023, without further action, it starts updating. no other action Unknown reason since it starts updating after nearly 1 day after resetting SIM7000 issue. Unknown
52
NEW_818/07/202313:41NEWStop updating on web 17/07/202305:050.5mV--------replaced new battery The power is running out. Flat battery
53
NEW_218/07/202314:33NEWStop updating on web 18/07/202308:413.549V-During the loop, the voltage is around 1.58V to 2.3V (most time is aound 2.3V). When the loop ends, the voltage is around 1.2V to 1.9V. --https://drive.google.com/file/d/1bTT6Vwt-uoPIN4ohGiFZcGTOlLqciczq/view?usp=share_linkreset SIM7000--start updating on web no other action issue with sim7000 communication. The issue is solved after resetting simcom7000. AT MEGA is working well. SIM7000 Issue
54
OLD_1418/07/202313:46OLDStop updating on web 17/07/202302:403.575VInitial 7mV. When the loop starts, the voltage increases to 10mV~ 23mV. When loop finishs, back to 7mV. Initial 1.9V. Suddently, the voltage drops to 0V. Then loop starts, the voltage increases to 2.2V~2.3V. When loop ends, the voltage drops to 1.9V. However, next loop, the initial voltage is 1.2V. During the loop, the voltage is around 1.2~1.5V. --https://drive.google.com/file/d/1B8WA5ra_UN4B6wzNvtbnrhHuKozIlhlb/view?usp=sharingreset SIM7000--start updating on web no other action issue with sim7000 communication. The issue is solved after resetting simcom7000. AT MEGA is working well. SIM7000 Issue
55
NEW_819/07/202313:34NEWStop updating on web 19/07/202307:474.159V-Initial 1.88V. Suddently, the voltage drops to 0V. Then loop starts, the voltage increases to around 2.1V . When loop ends, the voltage drop to 1.8V.https://drive.google.com/file/d/1Uqw8fpPi049vzo4fiiugcJju68EdKeOF/view?usp=sharingreset SIM7000--start updating on web no other action issue with sim7000 communication. The issue is solved after resetting simcom7000. AT MEGA is working well. SIM7000 Issue
56
OLD_1219/07/202314:17OLDStop updating on web 18/07/202310:143.536V-Always 1.8V. --No output Reset AT MEGA---start updating on web no other action ATMEGA issue; reconnecting battery to restore normal logging.ATMEGA Issue
57
OLD_1321/07/202316:30OLDStop updating on web 21/07/202302:333.663V-initial 1.9V. During the loop, the voltage is around 2.22V (most time) to 1.6V. When the loop ends, the voltage back to 1.9V. --https://drive.google.com/file/d/18DtXNNrzEqg88OqS6g5tQ5lnCPrK9Hr4/view?usp=sharingreset SIM7000--start updating on web no other action Issue with sim7000 communication SIM7000 Issue
58
OLD_1224/07/202316:45OLDStop updating on web 21/07/202301:560V---------start updating on web no other action The power is running out. Flat battery
59
NEW_025/07/202314:52NEWStop updating on web 25/07/202300:070V-------replaced new battery -start updating on web no other action The power is running out. Flat battery
60
NEW_325/07/202314:56NEWStop updating on web 23/07/202308:182.736V-------replaced new battery -start updating on web no other action The power is running out. Flat battery
61
OLD_125/07/202315:02OLDStop updating on web 22/07/202320:470v-------replaced new battery -start updating on web no other action The power is running out. Flat battery
62
BoSL_logging_delay_480s25/07/202314:27OLDStop updating on web 22/07/202313:343.86V-Initial 2.2V. Sometimes, drops to 1.6V. --https://drive.google.com/file/d/1YVKiFYqfnjanxvKKuABP2JIj7540fztB/view?usp=sharing-reset SIM7000reconnected battery -No response after resetting SIM7000. Start updating on web after reconnecting battery. no other action Issue with SIM7000 communication with network. SIM7000 Issue
63
BoSL_logging_delay_600s25/07/202314:43OLDStop updating on web 24/07/202318:003.884V-Initial 2.2V and stable. Sometimes, drops to 1.6V. --https://drive.google.com/file/d/1mjBfAnzPBvedW9wdji7-9ZohrQSAHzdm/view?usp=sharing-reset SIM7000--start updating on web no other action Issue with SIM7000 communication. SIM7000 Issue
64
NEW_107/08/202316:44NEWStop updating on web 02/08/202315:162.717V2.717V--------When started testing, noticed the antenna was dropped. The voltage of battery is 2.717V, BoSL board without battery is around 0.657V. start updating on web no other action The power is running out. Flat battery
65
NEW_207/08/202316:54NEWStop updating on web 02/08/202315:522.536V2.535V--------While unplugging, the voltage of battery is 2.527V. start updating on web no other action The power is running out. Flat battery
66
NEW_baudrate07/08/202317:03NEWlogging but 3.3V pin Voltage is abnormal3.48V3.827VNANA
67
NEW_307/08/202317:02NEWStop updating on web 27/7/202303:513.516v3.303v-Initial 1.7~1.8V. Suddently, the voltage dropped to 0V and then loop started. During the loop, the voltage is around 2.1~2.3V. --https://drive.google.com/file/d/1vKCT5eibGyhz9xTVWoknsUTml-BJzFBu/view?usp=sharing-reset SIM7000--start updating on web no other action Issue with SIM7000 communication. SIM7000 Issue
68
OLD_107/08/202315:21OLDStop updating on web 01/08/202320:243.6263.3Valways 0V1.3V, 0.79Vno outputhttps://drive.google.com/file/d/1DwvpsWy0A4iz8xqqy8jWeJslXpKhcUbS/view?usp=drive_linkreset SIM7000start updating on web no other action Issue with SIM7000, no responce to AT CommandsSIM7000 Issue
69
OLD_607/08/202316:38OLDStop updating on web 03/08/202301:181.355V1.355Vunplug battery voltage is 0V, BoSL board without battery is around 0.6V
70
NEW_408/08/202315:18NEWStop updating on web 31/07/202321:240.4mV12.7mV-------repalced new battery start updating on web no other action The power is running out Flat battery
71
NEW_608/08/202315:25NEWStop updating on web 02/08/202317:390.2mV8mV-------replaced new battery unplug, the voltage of battery is 0.1mV. BoSL board without battery is 36.7 mV. start updating on web no other action The power is running out Flat battery
72
NEW_908/08/202315:38NEWStop updating on web 06/08/202314:173.634V3.301VThe voltage is fluctuating from 0 mV to 485 mV. Initial 1.2 V. Suddently, the voltage dropped to 0v. When the loop starts, the voltage is increasing to around 2.2 V. During the loop, the voltage is fluctuating from 1.7V to 2.2V. https://drive.google.com/file/d/1ensFCfgEbszR6zdlNbn1wpHK75sWBkQs/view?usp=sharingno outputhttps://drive.google.com/file/d/1wNBF18f09fUh7lJc42Cqe52UbWzM_rzP/view?usp=sharingreset AT MEGAreset SIM7000replaced new battery After pressing reset buttom, there is no response from BoSL TX. Then resetting SIM7000, there is still no response from BoSL TX. But the voltage of Vpp and 3.3V are dropped to 1.36V. However, the battery voltage is 3.6V. When unplugging the battery, the voltage of Vpp and 3.3V are still as 1.36V. Once plugging in the battery, then voltage of Vpp and 3.3 V are suddently back to 3.6V. start updating on web 1.8V issue
73
NEW_1009/08/202316:26NEWStop updating on web 03/08/202311:241.3mV10mV1) Unplugged battery and tested battery voltage, 0V
Flat battery
2) checked web log, it's still logging when voltage is 2.8V
03/08/23 01:18:05 AM,2810,,,,,,,16
03/08/23 01:24:45 AM,2832,,,,,,,99
start updating on web Normal battery power run outFlat battery
74
NEW_309/08/202315:30NEWStop updating on web 08/08/202318:173.452V3.303V0.00mV when no reading from BoSL TX
, 0.006V when there are output from BoSL TX
1.341V, 0.79V, 0Vno outputhttps://drive.google.com/file/d/1ThtcQVduhKXG7FU7rxXrIIRdYsSbRy4n/view?usp=drive_linkreset AT MEGAreset SIM7000replaced new battery start updating on web SIM7000 issue, ATMega cannot power on SIM7000 by pulling down POWERKEY.
ATMega sends AT Commands, no response from SIM7000
SIM7000 Issue
75
OLD_X09/08/202316:43OLDStop updating on web 01/08/202316:362.68V2.68Vno outputreset AT MEGAUnplugged battery and tested battery voltage, 2.68V Flat batterystart updating on web Normal battery power run outFlat battery
76
BoSL_logging_delay_480s10/08/202313:59OLDStop updating on web 01/08/202310:303.545v3.301V0.3mV. 0.9V -----replaced new battery1)Once connected the Uno, the voltage of Vpp dropped to 1.4V. The voltage of power key and status pin are 0.9v and 0.3mV, respectively.
2)Remove the connection with Uno board, the voltage of Vpp is 1.256V and the value is constant.
3)Unplugged battery, the battery voltage is 3.5V.
start updating on web 1.8V issue
77
BoSL_logging_delay_600s10/08/202314:42OLDStop updating on web 31/7/202306:033.57V3.307VWhile in the loop, the voltage is 2.42V. Once loop ends, the voltage is dropped to 1.8V. While in the loop, the voltage is 2.1V ~ 1.8V. Once the loop ends, the voltage is dropped to 1.5V to 1.7V. https://drive.google.com/file/d/13HqFHxmoZCzz1ismjxIXxIkeUv1RC3K4/view?usp=sharingno outputhttps://drive.google.com/file/d/1Oha78_5SM_ET-Fm4OLkOvteqjV6kDfPD/view?usp=sharingreset AT MEGA. reset SIM7000replaced new battery. 1) reset AT MEGA, there is no response from SIM7000 TX. The voltage of Vpp is 3.55v and constant.
2) reset SIM7000, the voltage of Vpp is 3.55V and constant. The board starts logging.
start updating on web 604 errorStack busy
78
NEW_014/08/202310:58NEWStop updating on web 11/08/202315:223.835V3.302V4.3 mV. Initial 1.8V. The voltage varies from 1 V to 1.8 V during the testing. no output no outputInitial no output.
https://drive.google.com/file/d/1sPyoU59wANErXBp9wiTscRdJtY9d6xUh/view?usp=sharing
reset AT MEGAreplaced new battery 1) The voltage of Vpp is constant during the testing.
2) After pressing reset bottom and logging recoveries, the voltage of Vpp is 3.8 V but the voltage of 3.3V is 4.167V.
3) After replacing the new battery, the voltage of Vpp and 3.3v are 4.173 V and 4.462V, respectively.
start updating on web After resetting the BoSL Board, the logging starts. AT MEGA issue
79
OLD_414/08/202312:45OLDStop updating on web 13/08/202322:033.002V3.002V4.2mV. During the loop, the voltage increased to 2.42V. initial 2.1V. During the loop, the voltage varies from 2.1V to 1.8V. Since the loop ends, the voltage dropped to 1.7V. https://drive.google.com/file/d/1DiHmZzbz8Nvz_46_OeLP1QowuizgwT_o/view?usp=sharingNo outputhttps://drive.google.com/file/d/1DiHmZzbz8Nvz_46_OeLP1QowuizgwT_o/view?usp=sharingreset AT MEGAreset SIM7000replaced new battery 1) After 30 mins, the voltage of 3.3V dropped to 132.5 mv. 2) After resetting the BoSL Board, the voltage of 3.3V back to 2.9V. However, there is still no logging.
3) There is still no logging after resetting SIM7000 several times. 4)After replacing new battery, the logging starts.
start updating on web After resetting the BoSL Board and SIM7000, there is still no logging. However, the logging starts after replacing new battery. Flat battery
80
OLD_114/08/202311:35OLDStop updating on web 12/08/202301:183.544V3.302V5.6mVinitial 2.1V. During the loop, the voltage varies from 1.42V to 2.1V. Since the loop ends, the votlage dropped to 1.0V. https://drive.google.com/file/d/1_iwMe2JOe73mM1wDbijYViiJvmn0JzGr/view?usp=sharingno outputhttps://drive.google.com/file/d/1AdMRVIbvT0cQWnrMcKA2ZF1Z7NSXw4pT/view?usp=sharing-reset SIM7000replaced new battery 1) During the testing, the voltage of Vpp is constant but the voltage of 3.3V is 3.88V. 3)After logging starts, the voltage of 3.3 V increased to 3.8V.
2) After resetting SIM7000, the voltage of 3.3V dropped to 3.3V.
start updating on web Communication Issue with SIM7000. After resetting SIM7000, logging starts. SIM7000 issue
81
OLD_714/08/202314:14OLDStop updating on web 13/08/202315:553.367V3.303V5.2mVDuring the loop, the voltage varies from 2.1V to 1.9V. sometimes, dropped to 1.4 V. Since the loop ends, the voltage dropped to 1.7V.
https://drive.google.com/file/d/1DiHmZzbz8Nvz_46_OeLP1QowuizgwT_o/view?usp=sharing
No outputhttps://drive.google.com/file/d/1gKOMWwDnsRxbSbRwjC54PSQNzO4N4U9I/view?usp=sharingreset ATMEGAreset SIM7000replaced new battery 1) After loop ends (SLEEP), the voltage of 3.3V increased to 3.712V. After restting AT MEGA, 3.3V Voltage back to normal (3.3V.)
2) The voltage of Vpp is constant.
3)There is no logging after resetting ATMEGA
start updating on web The logging starts after resetting SIM7000. SIM7000 issue
82
NEW_baudrate18/08/202315:34NEWStop updating on web 17/08/202313:380V0Vreplaced new battery Battery voltage is 0V after unplugged
The last logging voltage is 2.8V
17/08/23 03:31:23 AM,2834,,,,,,,13,
17/08/23 03:38:17 AM,2831,,,,,,,15,
start updating on web Normal battery power run out1.8V issue
83
NEW_518/08/202311:16NEWStop updating on web 16/08/202303:222.611V2.610Valways 0.1mValways 0.801VNo outputreset ATMEGAreplaced new battery There is no output after pressed reset button
Battery voltage is 2.611V after unplugged
The last logging voltage is 2.8V
15/08/23 05:16:14 PM,2847,,,,,,,99,,,,,
15/08/23 05:22:37 PM,2842,,,,,,,99,,,,,
start updating on web Normal battery power run outFlat battery
84
OLD_818/08/202311:47OLDStop updating on web 16/08/202314:080V0Vreplaced new battery Battery voltage is 2.611V after unplugged
The last logging voltage is 3.1V
16/08/23 04:08:40 AM,T,,,3130,,,,,,,
16/08/23 04:08:42 AM,T,,,3130,,,,,,,
start updating on web Normal battery power run outFlat battery
85
OLD_1018/08/202312:16OLDStop updating on web 16/08/202317:222.961V2.960V5.2mV0.793V, 1.205V, 0Vhttps://drive.google.com/file/d/1Uu4N6p889AR1GUsR9xtfPBDNK51wrJf0/view?usp=drive_linkreset ATMEGAreset SIM7000replaced new battery Pressed reset button, the http request still failed.
After reset sim7000, the http request still failed.
After replaced new battery, the http request succeed.
start updating on web "+SAPBR: 1,3,"0.0.0.0""
means no IP assigned.
SIM7000 issue. SIM7000 is responsive to AT Commands, but http request failedregister failed
86
BoSL_logging_delay_480s18/08/202313:22OLDStop updating on web 17.08/202312:293.315V3.302V2.600V1.407V, 0.797V, 0Vhttps://drive.google.com/file/d/1dzpHIwZ5m5ZRIAJTr5qyIeEEL4oUeJIQ/view?usp=drive_linkreset ATMEGA
BoSL TX output after reset
https://drive.google.com/file/d/1DLyQQNGzbKEaway7I6oHTTkKmf4oa8OL/view?usp=drive_link
reset SIM7000
BoSL TX output after sim reset
https://drive.google.com/file/d/18ssR_avTbE7125HgGpAH0pqP3WGHVbJc/view?usp=drive_link
replaced new battery Pressed reset button, the http request still failed.
After reset sim7000, the http request still failed.
When test it with a big antenna(30cm), the http request succeed.
After replaced new battery and connect to paper antenna, the http request succeed.
start updating on web I guess low level of power can cause http request fail, becuase signal is weak when power is low. A big antenna may reduce the rate of http request failure. -- FelixSIM7000 issue. SIM7000 is responsive to AT Commands, but http request failedDNS error
87
NEW_221/08/202313:42NEWStop updating on web 19/08/202304:443.841V3.3VWhile in the loop, voltage varies from 5mv to 13 mV. When the loop ends, the voltage is 5mV. While in the loop, voltage varies from 2.2V to 1.5V. https://drive.google.com/file/d/1Y1WCNF1iAhMOeYzWaT88wMK_ZICXeiCn/view?usp=sharingno output https://drive.google.com/file/d/1DE9iLMirPievUCbG7vWgWITQ-9qc0rp6/view?usp=sharingreset ATMEGA, no logging reset SIM7000
replaced new battery 1) While loop ends, 3.3 V voltage increased to 4.17V. During the loop, the voltage of 3.3V is 3.3V.
2) The voltage of power key is constant.
start updating on web SIM7000 issue, no response to AT Commands.SIM7000 issue
88
OLD_521/08/202311:42OLDStop updating on web 19/08/202323:372.745V2.744Valways 0Valways 0.805Vno outputreset ATMEGA
no output after reset
Battery voltage is 2.751V after unplugged
The last logging voltage is 3.1V
19/08/23 01:46:07 AM,T,,,3195,,,,,,,
19/08/23 01:52:58 AM,T,,,3194,,,,,,,
start updating on web Normal battery power run outFlat battery
89
OLD_X21/08/202314:09OLDStop updating on web 12/08/202301:163.61V3.32V0V0.80Vhttps://drive.google.com/file/d/1fX8EumEf-9Q9aGGHrW3YmsBEEJp5CAuu/view?usp=drive_linkreset ATMEGA
output after reset:
https://drive.google.com/file/d/1vPlkLUVQG6fCWDDoYYqjgcrfC-vH3LZr/view?usp=drive_link
reset SIM7000
start to log after sim reset
https://drive.google.com/file/d/12RK9E1OOpfSi-4ZtQgsd8ZMIk6Dik51I/view?usp=drive_link
replaced new battery SIM7000 issue, no response to AT CommandsSIM7000 issue
90
OLD_922/08/202310:33OLDStop updating on web 18/08/202320:432.738V2.737Valways 0Valways 0.781Vno outputreset ATMEGA
BoSL TX no output
Vpp and V3V keep same
replaced new battery Battery voltage is 2.738V after unplugged
The last logging voltage is 3.1V
18/08/23 10:43:05 AM,T,,,3131,,,,,,,
start updating on web Normal battery power run outFlat battery
91
BoSL_logging_delay_600s23/08/202310:26OLDStop updating on web 23/08/202304:483.758V3.307V2.600V1.377V, 0.780V, 0Vhttp request failed, 604 error, but loging succeed on the web
https://drive.google.com/file/d/1TJt3I_CyyxOAwUGMPG4trQVfHTXfGzUB/view?usp=drive_link
reset ATMega
http request fails with 604 error, but loging succeed on the web
https://drive.google.com/file/d/1KaYgZ6T2JCXcx_eGawgqH4wYUE7DbJpB/view?usp=drive_link
reset sim7000
http request fails with 604 error, but loging succeed on the web
https://drive.google.com/file/d/1t5xmJevanvbbLTWVMCnwwb6-aAixlThT/view?usp=drive_link
replaced new battery Tested with a big antenna(30cm), http request fails with 604 error, but logging succeed on the webstart updating on web SIM7000 issue, communicate issue with web serverStack busy
92
NEW_124/08/202313:29NEWStop updating on web23/08/202319:503.839V3.302V-------replaced new battery As connecting with Uno board, 3.3V suddently dropped to 52mV. Somewhere of BoSL Board may be short circuit, the BoSL could not recovery. Since the battery has been plugged out, then BoSL Board recoveried.
93
OLD_1024/08/202313:53OLDStop updating on web23/08/202317:304.409V3.3VWhile sleep, 4.3mV. in the loop, the voltage varies from 8.8mv to 15.8mV. While sleep, the voltage is 1.55V. During the loop, the voltage vaties from 1.8V to 2.3V. https://drive.google.com/file/d/1okqTrCOocp3ds3KmPTDOXKOP1T5q8S0q/view?usp=sharing-https://drive.google.com/file/d/1okqTrCOocp3ds3KmPTDOXKOP1T5q8S0q/view?usp=sharingreset AT MeGA
BoSL TX output after resetting:
https://drive.google.com/file/d/1HHLI7AboQ7vA9DFRVeMOeu-zCcoAwB7e/view?usp=sharing
reset sim7000:
BoSL TX output after resetting
https://drive.google.com/file/d/1Ssy-PzH3qOdDjvWnH0-NlxnGNXzCc7C0/view?usp=sharing
replaced new battery 1)while sleep, the voltage of 3.3V increases to 4.356V. During the loop, voltage of 3.3V is 3.3V.
2) The voltage of Vpp is constant.
3) There is no logging after resetting ATMEGA.
4) After resetting SIM7000, starts logging. Then, new battery is replaced.
start updating on web SIM7000 issue. There is problem with communication with AT MEGA. SIM7000 issue.
94
OLD_225/08/202309:47OLDStop updating on web24/08/202313:312.978V2.983V0V0.795Vreplaced new battery double check Vpp after connect to Uno TX and GND, 1.493V
remove connection to Uno, check Vpp again: 1.281V 3V3:1.282V
battery plug point: 1.282V
Battery voltage level is 2.985 when unplug
start updating on web Vpp and 3V3 dropped to 1.28V when connected to Uno TX and GND
No chance to test ATMega
1.8V issue
95
OLD_825/08/202309:43OLDStop updating on web25/08/202309:434.10V3.30V0V0.774Vhttps://drive.google.com/file/d/16PwLZsnQLRe5MBc1uj1V9i1fFyJeXZNL/view?usp=drive_linkstart updating on web Unknown, it started to log when connect to Uno TX and GNDUnknown
96
Openbearer25/08/202316:37OLDStop updating on web 23/08/202313:010.3mV16.1mV-------replaced new battery start updating on web Flat battery
97
OLD_728/08/202311:50OLDStop updating on web 28/08/202300:323.967V3.3V7.9mvwhile in sleep, the voltage is 1.9V. During the loop, the voltage is 2.1V. https://drive.google.com/file/d/1ScJxjptvXG-8IF7QLUw1tv_1FYz6tqxC/view?usp=sharing-https://drive.google.com/file/d/1f2eAk8mpEXRQI8Q0xuoL_ASA8gBwcAGm/view?usp=sharingreset AT MEGA (still no logging)
BoSL TX output after resetting: https://drive.google.com/file/d/13LWQq7RjfoaXY8HYX3GIDijnQ_Qx8104/view?usp=sharing
reset SIM7000
BoSL TX output after resetting:
https://drive.google.com/file/d/1r7-oWEVUBhLCCq7JRIBR-IJFhgNj6anl/view?usp=sharing
replaced new battery(after logging)1) connect to Uno: the Vpp is 3.968V, 3.3V is 4.295V (loop ends)
2) During the loop, 3.3V is 3.3V but Vpp is constant.
start updating on web SIM7000 issue. No response to AT MEGASIM7000 issue.
98
OLD_1028/08/202313:23OLDStop updating on web 27/08/202323:024.046V3.3V2.2mV (sleep mode)
10 mV during loop
1.84V at sleep mode
During the loop, voltage varies from 1.6V to 2.2V.
https://drive.google.com/file/d/1Y6_uG4jHOMlNEwYBbnbyb11_a9dYHDvW/view?usp=sharingno outputhttps://drive.google.com/file/d/1PZDpALi5KR36moSKg2qGDv0Vmm4W-p-t/view?usp=sharingreset ATMEGA (no logging):
https://drive.google.com/file/d/1OIB_S84wC0y16nyC97BQpe5WaA6wfHjn/view?usp=sharing
reset SIM7000
https://drive.google.com/file/d/190FXnUeCr6eKrWcTSBoFVH89bLe3gcBL/view?usp=sharing
replaced new battery(after logging)1) connect to Uno: the Vpp is 4.047V; 3.3V is 3.3V
2)While loop end, 3.3V increased to 4.364V
3)After reset ATMEGA, there is no logging
4)After reset SIM7000, logging starts
5)However, the 3.3 V still increased to 4.36V. The Vpp is constant.
start updating on web SIM7000 issue. No response to AT MEGASIM7000 issue.
99
BoSL_logging_delay_480s29/08/202311:35OLDStop updating on web 28/08/202319:173.790V3.302V2.600V1.408V, 1.3XV, 0.8Vhttps://drive.google.com/file/d/1-1QPY2SXzQNxTSOaHDYjeVPoqsZDR2XN/view?usp=drive_linkreplaced new battery(after logging)start updating on web Tried to use a passthough BoSL board to connect TX, continusly get empty characters. Unknown, when connect to passthrough Uno TX, it started to log.Unknown
100
OLD_829/08/202311:46OLDStop updating on web 28/08/202323:343.956V
3.299V152mV0.774VUnknown, it started to log during the test.Unknown