1 | Restroom Plumbing System Summary — Levels L1–L3 (Greywater Revision) | |||||||||||||||||||||||||
2 | Project: 261105 Piping Systems for Stacked Multi-User RR | Model export 2026-11-05 | All totals are live formulas from the detail tabs. | |||||||||||||||||||||||||
3 | ||||||||||||||||||||||||||
4 | 1. System Overview | |||||||||||||||||||||||||
5 | System | Serves | Pipe Type / Material | Riser Size (in) | Branch Length (ft) | Riser Length (ft) | Garage Trunk + Drop (ft) | Total Length (ft) | Pipe Pieces | Fittings | ||||||||||||||||
6 | Domestic Cold Water | Lavatories (potable); makeup to GW tank | Copper - Type L | #VALUE! | 25.4 | 37.1 | 19.9 | 82.4 | 32 | 28 | ||||||||||||||||
7 | Domestic Hot Water | Lavatories | Copper - Type L | #VALUE! | 21.5 | 37.4 | 19.9 | 78.8 | 29 | 25 | ||||||||||||||||
8 | Greywater Supply | Water closets & urinals (flush) | PVC Sch 80 (purple) | #VALUE! | 78.6 | 28.8 | 28.2 | 135.6 | 65 | 62 | ||||||||||||||||
9 | Sanitary | Water closets & urinals | PVC - DWV (Sch 40) | #VALUE! | 74.1 | 35.6 | 19.5 | 129.2 | 74 | 58 | ||||||||||||||||
10 | Greywater Drain | Lavatories → GW tank | PVC - DWV (Sch 40) | #VALUE! | 23.4 | 35.6 | 23.7 | 82.7 | 42 | 47 | ||||||||||||||||
11 | Vent | Circuit vents, sanitary branches | PVC - DWV (Sch 40) | #VALUE! | 23.9 | 35.7 | 19.6 | 79.2 | 11 | 7 | ||||||||||||||||
12 | TOTAL | 247.0 | 210.2 | 130.8 | 587.9 | 253 | 227 | |||||||||||||||||||
13 | ||||||||||||||||||||||||||
14 | 2. Pipe Length by Level (ft) | |||||||||||||||||||||||||
15 | System | L1 Branches | L2 Branches | L3 Branches | Risers | Garage Trunks + Drops | Total | |||||||||||||||||||
16 | Domestic Cold Water | 8.5 | 8.5 | 8.5 | 37.1 | 19.9 | 82.4 | |||||||||||||||||||
17 | Domestic Hot Water | 7.2 | 7.2 | 7.2 | 37.4 | 19.9 | 78.8 | |||||||||||||||||||
18 | Greywater Supply | 26.2 | 26.2 | 26.3 | 28.8 | 28.2 | 135.6 | |||||||||||||||||||
19 | Sanitary | 24.7 | 24.7 | 24.7 | 35.6 | 19.5 | 129.2 | |||||||||||||||||||
20 | Greywater Drain | 7.8 | 7.8 | 7.8 | 35.6 | 23.7 | 82.7 | |||||||||||||||||||
21 | Vent | 8.0 | 8.0 | 8.0 | 35.7 | 19.6 | 79.2 | |||||||||||||||||||
22 | TOTAL | 82.3 | 82.3 | 82.4 | 210.2 | 130.8 | 587.9 | |||||||||||||||||||
23 | ||||||||||||||||||||||||||
24 | 3. Fixtures and the Systems Serving Them | |||||||||||||||||||||||||
25 | Fixture | L1 | L2 | L3 | Total | Drain To | Supplied By | |||||||||||||||||||
26 | Water Closets | 6 | 6 | 6 | 18 | Sanitary | Greywater Supply | |||||||||||||||||||
27 | Urinals | 2 | 2 | 2 | 6 | Sanitary | Greywater Supply | |||||||||||||||||||
28 | Lavatories | 4 | 4 | 4 | 12 | Greywater Drain | Domestic Cold + Hot Water | |||||||||||||||||||
29 | TOTAL | 12 | 12 | 12 | 36 | |||||||||||||||||||||
30 | ||||||||||||||||||||||||||
31 | 4. Greywater Balance (estimate — see Greywater Balance tab) | |||||||||||||||||||||||||
32 | Metric | Value | Notes | |||||||||||||||||||||||
33 | Share of flush demand met by greywater | 11% | Driven by assumptions on the Greywater Balance tab | |||||||||||||||||||||||
34 | Potable makeup required (gal/day) | 1,179 | Air-gapped CW makeup to tank | |||||||||||||||||||||||
35 | ||||||||||||||||||||||||||
36 | 5. Model QA Results (Revit check, 2026-11-05) | |||||||||||||||||||||||||
37 | Check | Result | Notes | |||||||||||||||||||||||
38 | Pipes in model | 253 | Sum of pipe pieces on Pipe Quantities tab | |||||||||||||||||||||||
39 | Pipe fittings in model | 227 | Sum on Fittings tab | |||||||||||||||||||||||
40 | Unconnected fixture connectors | 0 | All 36 fixtures fully connected and assigned to the correct systems | |||||||||||||||||||||||
41 | Unconnected fitting connectors | 0 | ||||||||||||||||||||||||
42 | Open pipe ends | 11 | 6 riser tops (GWS riser ends in an elbow at L3) + 5 garage trunk/drop ends — all intentional | |||||||||||||||||||||||
43 | Cross-system pipe clashes | 0 | Includes pipes vs. placeholder tank/pump | |||||||||||||||||||||||
44 | Model warnings | 0 | ||||||||||||||||||||||||
45 | Piping systems | 6 | One Revit system per system type | |||||||||||||||||||||||
46 | ||||||||||||||||||||||||||
47 | ||||||||||||||||||||||||||
48 | ||||||||||||||||||||||||||
49 | ||||||||||||||||||||||||||
50 | ||||||||||||||||||||||||||
51 | ||||||||||||||||||||||||||
52 | ||||||||||||||||||||||||||
53 | ||||||||||||||||||||||||||
54 | ||||||||||||||||||||||||||
55 | ||||||||||||||||||||||||||
56 | ||||||||||||||||||||||||||
57 | ||||||||||||||||||||||||||
58 | ||||||||||||||||||||||||||
59 | ||||||||||||||||||||||||||
60 | ||||||||||||||||||||||||||
61 | ||||||||||||||||||||||||||
62 | ||||||||||||||||||||||||||
63 | ||||||||||||||||||||||||||
64 | ||||||||||||||||||||||||||
65 | ||||||||||||||||||||||||||
66 | ||||||||||||||||||||||||||
67 | ||||||||||||||||||||||||||
68 | ||||||||||||||||||||||||||
69 | ||||||||||||||||||||||||||
70 | ||||||||||||||||||||||||||
71 | ||||||||||||||||||||||||||
72 | ||||||||||||||||||||||||||
73 | ||||||||||||||||||||||||||
74 | ||||||||||||||||||||||||||
75 | ||||||||||||||||||||||||||
76 | ||||||||||||||||||||||||||
77 | ||||||||||||||||||||||||||
78 | ||||||||||||||||||||||||||
79 | ||||||||||||||||||||||||||
80 | ||||||||||||||||||||||||||
81 | ||||||||||||||||||||||||||
82 | ||||||||||||||||||||||||||
83 | ||||||||||||||||||||||||||
84 | ||||||||||||||||||||||||||
85 | ||||||||||||||||||||||||||
86 | ||||||||||||||||||||||||||
87 | ||||||||||||||||||||||||||
88 | ||||||||||||||||||||||||||
89 | ||||||||||||||||||||||||||
90 | ||||||||||||||||||||||||||
91 | ||||||||||||||||||||||||||
92 | ||||||||||||||||||||||||||
93 | ||||||||||||||||||||||||||
94 | ||||||||||||||||||||||||||
95 | ||||||||||||||||||||||||||
96 | ||||||||||||||||||||||||||
97 | ||||||||||||||||||||||||||
98 | ||||||||||||||||||||||||||
99 | ||||||||||||||||||||||||||
100 |