5.17 Tystar17 - 17HTOSTDA
 Share
The version of the browser you are using is no longer supported. Please upgrade to a supported browser.Dismiss

View only
 
 
ABCDEFGHIJKLMN
1
2
Tystar17 - 17HTOSTDA
3
4
Process Specification
Process Performance
5
Tool Name:Tystar17
6
Description: This monitor tracks oxide thickness and uniformity.
7
8
Recipe:17HTOSTDA
9
Layer Material: oxide on silicon
10
11
Targeted Results:
12
TargetDescription
13
Thickness [A]:1600Measured using nanoduv
14
15
Uniformity [%]:>90%Calculated using (MAX-MIN) / (MAX+MIN) method on thickness data.
16
17
18
Process Conditions:
19
Deposition:
20
O2 [sccms]:135
21
SiH4 [sccms]:90
22
PH3[sccms]25
23
Temperature [degrees C]:
450
24
Time [HH:MM:SS]:00:30:00
25
26
QM Process Procedure:
27
StepToolDescription
28
Stock WaferNew Wafer6-inch P-Type Test Wafer
29
Oxide GrowthTystar1730 minute oxide growth
30
Film Thickness / RInanoduv5-point film thickness / RI
31