Product NameZigbee Boiler
3
Product Type
4
Product Model
5
ProductIDvqaajp1a
6
DP IDDP NameDP CodeData transfer typeData TypeData AttributesRemarks
7
1Switch 1switch_1Issue and reportbool
8
14Restart Statusrelay_statusIssue and reportenumEnumerated values:off,on,memory
9
16Backlight Switchbacklight_switchIssue and reportbool
10
20Add Electricityadd_eleIssue and reportvalueValues range:0-50000,Pitch:100,Unit:kwh
11
21Current Currentcur_currentOnly reportvalueValues range:0-30000,Pitch:1,Unit:mA
12
22Current Powercur_powerOnly reportvalueValues range:0-50000,Pitch:1,Unit:W
13
23Current Voltagecur_voltageOnly reportvalueValues range:0-5000,Pitch:1,Unit:V
14
24Test Bittest_bitOnly reportvalueValues range:0-5,Pitch:1,Unit:null
15
101Delay timedelay_timeIssue and reportvalueValues range:0-999,Pitch:1,Unit:min
16
102Child lockchild_lockIssue and reportbool

17
103Work timework_timeOnly reportvalueValues range:0-999,Pitch:1,Unit:min
18
104Total timetotal_timeOnly reportvalueValues range:0-999,Pitch:1,Unit:min
19
20
Glossary
21
Product nameProduct name, also the diaplayed ddefault name after App adds device
22
Product KeyUnique identification code for the product
23
Data pointThe abstract for the specific data point of smart device, with the purpose for describing product functions and their parameters
24
Product PIDData point and its parameters are transmitted via data point ID
25
Display nameData point name, also the default name to display the functions in the App.
26
Identification nameData point code,is the unique value for device's multi-language management
27
Data transmission typeType that can be issued and reported: For the controlled equipment, you can read its device status information and change equipment status;

Type that can only be reported: For the controlled device, you can read its device status information, but can't change the device status;
Type that can only be issued: For the controlled device, you can read the device status information, but can't change the device status
28
Data type
29
Boolean typeNon-true or false binary variable. Such as: Switch
30
Numeric typeApplicable to data that can be linearly adjusted. Such as temperature adjustment (Range: 20-50. Pitch: 1. Unit:℃)
31
Enumerated typeCustom finite set values. Such as: work grade (low, mid-range, high-grade)
32
Fault typeDedicated to reporting and doing statistics of equipment failure data points, can be set to 1 or more failures. Such as: temperature failure, sensor failure
33
Character typeUsed for data points transmitted as strings. Such as: RGBW value of the color lamp
34
RAW typeFor data that is transmitted in binary form. Such as the infrared learning of air conditioner
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100