ABCDEFGHIJKLMNOPQRSTUVWXYZ
1
Date
(mm-dd-yyyy)
What was done?Who?Notes
2
01-14-2022- Check the anchor we installed last yearNick, Tzu-Yi
3
02-17-2022- Install wildlife camera and tide height reference rodNick, Tzu-YiThe height of the rod: ~122cm, mark every 15cm
4
10-03-2022- Swap memory card
- Take photos of the distance between dike and tower location
Tzu-Yi, Sarah
5
04-28-2022Helocopter fly
- Move stuff to RBM
- Battery box platform broken and make temporary platform
Rick, Zoran, Nick, Darion, Zoe, Evan
6
04-29-2022- Fix battery box platform and Rick, Zoran, Nick, Darion
7
05-03-2022- Put the sign in the entranceTzu-Yi, Sarah
8
05-09-2022- Solar panel platform
- Install tower foundation posts
Rick, June, Tzu-Yi
9
05-10-2022- Put solar panels on the platform
- Tower platform
Rick, June
10
05-17-2022- First layer of scaffolding
- Tower fencing (except the gate)
Rick, Tzu-Yi
11
05-19-2022- Put Charger&power&solat box on
- Connect batteries together
- Install diagnostic signals cable
- Install tower gate
Rick, Zoran,Tzu-Yi, Darion
12
05-20-2022- put second & third scaffoldings on
- Install logger & relay box
- Set up power system (connect solar panels, set up charger box, connect battery box and logger box)
* logger box devices were not powered
Rick, Zoran,Tzu-Yi, Darion, Evan (Zoran's son)
13
05-25-2022- Installed fencing around battery box, added stabalizers to solar pannel beams (Rick & June)
- Wiring & electrical connections in logger boxes (Zoran)
Rick, Zoran, & June
14
05-30-2022- Relay control connection
- Level the tower
- Adjust battery box platform
- Adjust power box location (a bit far away from the fencing)
- Install two booms
- Install PhenoCam
Rick, Tzu-Yi
15
06-01-2022- Install barometer tube
- Install EC system
- Install HMP sensors
- Adjust PhenoCam direction
Sara, Rick, June, Tzu-Yi
16
06-07-2022- Adjust PhenoCam direction
- Install radiometers (CNR4, PAR in&out, PRI in&out)
- Install LI-7200 silencer
- Mount RM Young (wiring not yet)
- Swap converter box fuse: 2mA → 10mA
Rick, Tzu-Yi
17
06-11-2022- Adjust PhenoCam focus
- Install NDVI
- Wire up RM Young
- Photos for poster
Tzu-Yi, Tin
18
06-13-2022- Install BF5, Rain gauge, SHF*3, soil temperature profiles*2Tzu-Yi, Darion
19
06-16-2022- install water probe pipe (not working)
- install guy anchors the tower
- fix soil temperature profile1
- clean LI-7700 mirror
- install cross braces for third layer and re-level top sensors
- install stair rails, not complete - need to move pump box
- install lightning rod (ground wire)
- replace rotten deck with new one
Rick, Tzu-Yimmt truck, Rick's truck
20
06-22-2022- Swap USB sticks
- Clean LI-7700 mirror
- Move smartflux2 GPS from logger box to tower top
Tzu-Yi, June
21
05-07-2022-Fixed NDVI sensor (temporary?)June, Sarah R
22
07-14-2022-Installed Water Table Probe & Uppdated Program on CR1000
-Cleaned 7700
-Installed 4way connector for NDVI sensor
-Stacked extra lumber on battery platorm
-Took Pictures
June, Sarah R- See logger program changes
23
07-26-2022-Set Up Calibration Tanks
-Calibrated & Cleaned Flux Sensors, Pulled Data
-Moved wildlife camera & Pulled SD card
-Adjusted Postion of NDFI & PRI Sensors
-Secured Scafolding Decks
-Move pump box and Installed Railing. Decided to not install lower inside railing. Stored on batt stand
June, Rick- mmt truck
- Rest 7200 Signal Strength
-Wildlife Camera Batteries need to be changed
24
08-18-2022- Clean LI-7200&LI-7700 mirrors
- Swap USB sticks & desiccants
- Swap reflected PAR sensor
- Measure static water table height
- Swap wildlife camera memory card (remained setup mode since last time)
Tzu-Yi, June- one new washer fluid left
- bring batteries for wilelife camera next time
25
08-30-2022- Swap LI-7200 inlet thermocouple
- Clean LI-7200&LI-7700 mirrors
- EC calibration
- Swap USB sticks & desiccants
- Measure static water table height
- No wildlife camera photos (left setup mode last time and batteries died out)
- Check rain gauge (clean the top half)
- Install bird spikes on radiometer boom
- Paint the top of the battery box
Tzu-Yi, June- one new washer fluid left
- bring batteries for wilelife camera next time
26
09-15-2022- Clean LI-7700 mirrors
- Swap USB sticks and wildlife camera memory card
- Swap wildlife camera batteries
- Pore water sampling (Sarah, Katrina, Abe, Forrest)
Tzu-Yi, Sarah, Katrina, Abe, Forrest- One and half new washer fluid left
27
09-27-2022- Clean LI-7700 mirrors
- Install a rope on the EC boom for lifting the end of the EC boom (to be optimized later)
- Clean solar panel surface
- Lift solar panels
- Install guy wires for solar panels (Anchors and support wires)
- Swap desiccants
- Paint the sealant on the wood cutting edge
- Seal the connection part of the battery box and the conduit
Rick, Tzu-Yi- Bring a new washer fluid
28
09-30-2022- Clean LI-7700 mirrors
- Measure water table
- Check water probe reference solution content
- Clean water probe
- Water probe calibration
- Swap USB sticks
- Run PhenoCam PIT scripts
- Put the wildlife camera battery cover back
Tzu-Yi, Hung-Chi- One and one-third washer fluid left
29
10-07-2022- Check LI-7200 signal strength reading (before/after open the optical path: 109/99)
- Clean LI-7200 rain cap
- Clean mirrors (LI-7200 & LI-7700)
- Swap LI-7200 outlet thermocouple
- EC Calibration
- Measure water table
- Water probe calibration
- Swap USB sticks
- Run PIT (PhenoCam installation tool) scripts again
- Swap wildlife camera memory card
Tzu-Yi, June- One and one-third washer fluid left
30
10-21-2022- Check barometers (CS106 & EC)
- Clean mirrors (LI-7200 & LI-7700)
- Measure water table
- Porewater sampling
Tzu-Yi, Sarah, Katrina- One washer fluid left
31
11-02-2022- Clean mirrors (LI-7200 & LI-7700)
- Clean LI-7200 rain cap
- EC calibration
- Swap USB sticks
- Measure water table
- Porewater sampling
Tzu-Yi, Sarah, Katrina- One washer fluid left
32
11-17-2022- Water probe calibration (refill reference electrode and calibrate pH)
- Clean mirrors (EC, PhenoCam)
- Swap USB sticks
- Swap Wildlife camera memory card
- Check wildlife camera battery (battery: full)
Tzu-Yi, Sarah, Katrina- Half washer fluid left
33
12-05-2022- Clean LI-7700 mirror
- EC calibration
- (Half solar panel collapse) Disconnect solar panel junctions and fix them higher
- Swap USB stick
Tzu-Yi, Hung-Chi- 0.3 washer fluid left
34
12-06-2022- Fix solar panels, was able to use all original wood. Mounted panels in horizontal orientationRick, Darian- 0.3 washer fluid left
35
12-15-2022- Installed anchors on N side of panels using long screws with extension. Put panels at proper angleRick, JuneMicromet truck, Marwan truck
36
01-25-2023- Confirm EC relay controls (it works)
- Clean LI-7700 and LI-7200 mirrors
- Swap LI-7200 rain cap
- EC calibration
- Clean water probe
- Swap wildlife camera memory card and batteries
- Check CSAT3 wicks
Tzu-Yi, Sarah, Katrina- 0.3 jars of washer fluid left
37
02-15-2023- Clean LI-7700 and LI-7200 mirrors
- Swap chemical bottles (desiccants) for EC (7700 & 7200)
- Refill water probe reference electrode and swap pH cap
- Water probe calibration
- EC calibration
- Measure water table
- Swap USB sticks
- Swap desiccants
Tzu-Yi, Sarah, Katrina- 1 jar of washer fluid left
38
03-09-2023- Pre-cleaning gas reading check
- Clean LI-7700/7200 mirrors and
- EC calibration
- Clean water probe and refill reference electrode
- Water probe calibration
- Swap USB sticks
- Clean mirrors (EC, PhenoCam, NDVI, PRI, BF5)
- Swap Wildlife camera memory card
- Check Wildlife camera battery (still full)
Tzu-Yi, Sarah- 1 jar of washer fluid left
39
04-03-2023- Pre-cleaning gas tank check
- Clean LI-7200 mirrors & LI-7700 mirrors & water probe & MET sensors
- Swap USB sticks & desiccants & wildlife camera memory cards
- Calibrate field gas tanks (CH4)
- Measure WTD
- Adjust LI-7200 sampling tube height and check LI-7200 seperation
Rick, Tzu-Yi, Joe- 1 jar of washer fluid left
- Wildlife camera battery level: Full
40
04-27-2023- Pre-cleaning gas tank check
- Clean LI-7700 mirrors (reset LI-7200 signal strength without opening)
- EC calibration
- Clean water probe
- Swap USB sticks & desiccants
- Measure WTD
June, Tzu-Yi- 0.8 jar of washer fluid left
41
05-16-2023- Pre-cleaning test
- Clean LI-7700 mirrors
- Calibrate LI-7700
- Swap LI-7200 (SN0551+AIU-1292 ⇒ SN0139+AIU-0446)
- Clean water probe
- Refill washer unit
- Swap USB stick
- Swap wildlife memory cards (battery level: ~50%)
- Swap desiccants
Tzu-Yi, Darian- 1 jar of washer fluid left
42
06-08-2023- Clean LI-7700/7200 mirrors
- EC calibration (can't open CH4 gas tank, so no span for LI-7700)
- Clean the water probe and check the reference electrode (still full)
- Swap USB sticks
- Swap desiccants
- Refill washer unit
- Clean lens/surface (PhenoCam, BF5, NDVI, PRI)
Tzu-Yi, Kelsey- 2 jar of washer fluid left
43
06-14-2023- Clean LI-7700 mirror
- Adjust LI-7700 spray nozzle angle
- Clean water probe
Tzu-Yi- 2 jar of washer fluid left
44
06-30-2023- Measure WTH
- Pre-cleaning test of LI-7200
- Clean LI-7700/7200 mirrors, MET sensors (PhenoCam, BF5, NDVI, PRI)
- EC calibration
- Water probe: cleaning, refilling pH ref solution, pH calibration
- Swap USB sticks
- Swap desiccants
- Swap wildlife camera memory card (battery level = 50%)
- Refill washer unit
- Put on new signs (only on the gate of tower)
Tzu-Yi, Himari- 1 jar of washer fluid left
45
07-10-2023- Measure WTH
- Pre-cleaning test of LI-7200
- Clean LI-7700 mirrors, MET sensors (PhenoCam, BF5, NDVI, PRI)
- Water probe: cleaning
- Swap USB sticks
- Swap desiccants
- Refill washer unit
- Put on new signs (dike)
- Measure canopy height
* Typha latifolia (173, 166, 170cm, AVG=169.7cm)
* Schoenoplectus acutus (190, 192, 190, AVG=190.7 cm)
* Anisantha sterilis (119, 115, 118, AVG=117.3 cm)
* Carex lyngbyei (74, 82, 80, AVG=78.7 cm))
Sara, Tzu-Yi, Binza, Kavita- 1 jar of washer fluid left
46
08-14-2023- Measure WTH
- Pre-cleaning test of LI-7200
- Clean LI-7200, LI-7700 mirrors, MET sensors (PhenoCam, BF5, NDVI, PRI), water probe
- Swap USB sticks
- Swap desiccants
- Swap wildlife camera memory card
- Refill washer unit
Tzu-Yi, Sarah- 0.5 jar of washer fluid left
47
08-28-2023- Troubleshoot water probe (reconnect signal wire of adapter)
- Clean LI-7700 mirror
Tzu-Yi, Sarah- 0.5 jar of washer fluid left
48
09-17-2023- Measure WTH
- Pre-cleaning test of LI-7200
- Clean LI-7200, LI-7700 mirrors, water probe, and MET sensors (PhenoCam, BF5, NDVI, PRI), water probe
- Swap USB sticks, desiccants, and rain cap
- Refill washer unit
- EC calibration
Tzu-Yi, Vanessa- 0.5 jar of washer fluid left
49
10-07-2023- Pre-cleaning test of LI-7200
- Measure WTH
- Clean LI-7200 mirrors & rain cap , LI-7700 mirrors, water probe, and MET sensors (PhenoCam, BF5, NDVI, PRI), water probe
- Swap USB sticks, desiccants, wildlife camera SD card & baterries
- Refill washer unit
- MET sensors power wiring change
- EC calibration
Tzu-Yi, Sarah- half jar of washer fluid left
50
11-08-2023- Clean LI-7700 mirrors, water probe, and MET sensors (PhenoCam, BF5, NDVI, PRI), water probe
- Swap fuse for MET sensor power control in loggerbox
- Swap USB sticks, desiccants
- Refill washer unit
- leave spare fuses in the logger box (1A*2, 2A, 3A; all MDL)
Tzu-Yi, SarahBRING washer fluid
51
11-25-2023- Pre-cleaning test of LI-7200
- Measure WTH
- Clean LI-7200 mirrors & rain cap , LI-7700 mirrors, water probe, and MET sensors (PhenoCam, BF5, NDVI, PRI), systems enclosure
- Swap USB sticks, desiccants, wildlife camera SD card
- Refill washer unit
- MET sensors power wiring change
- Put plastic bags in battery box
- EC calibration
Tzu-Yi, Sarah, TedBRING washer fluid
52
12-17-2023- Clean charger box / logger box / power box
- Clean LI-7700 mirrors & water probe & MET sensors
- Refill washer unit
- Swap desiccants & USB stick
Tzu-Yi, Sarah1 jar of washer fluid left
53
01-11-2024- EC calibration
- PreCleaning check
- Clean charger box / logger box / power box
- Measure WTH
- Clean LI-7200 & LI-7700 mirrors & water probe & MET sensors
- Refill washer unit
- Swap desiccants & USB stick & LI-7200 rain cap & wildlife camera SD card
Tzu-Yi, Sarah1 jrs of washer fluid left
54
01-30-2024- Swap LI-7700 washer tube (tube covered by mesh shield)
- Clean LI-7200 & LI-7700 mirrors & MET sensors
- EC calibration
- Swap USB stick & desiccants
- Unclog rain gauge (it's clogged)
- Refill washer unit
- Clean water probe
- Measure WTH
Tzu-Yi, Sarah, Katrina1 jar of washer fluid left
2/3-2/4 shut down EC system for power saving
55
02-02-2024- blast LI-7200 sampling tube using N2Tzu-Yi, Sarah1 jar of washer fluid left
56
03-06-2024"- PreCleaning check
- EC calibration
- Clean charger box / logger box / power box
- Measure WTH
- Clean LI-7200 & LI-7700 mirrors & water probe & MET sensors
- Refill washer unit
- Swap desiccants & USB stick & LI-7200 rain cap & wildlife camera SD card"
Tzu-Yi, Sarah1 jar of washer fluid left
57
04-09-2024- PreCleaning check
- EC calibration
- Clean charger box / logger box / power box
- Measure WTH
- Clean LI-7200 & LI-7700 mirrors & water probe & MET sensors
- Refill washer unit
- Swap desiccants & USB stick & LI-7200 rain cap & wildlife camera SD card
Tzu-Yi, Sarah0.5 jars of washer fluid left
58
05-09-2024- Clean LI-7200 & LI-7700 mirrors, water probe, MET sensors
- Pre-cleaning test
- Measure WTH
- Swap USB stick, desiccants
- Calibrate EC system
- Refill washer unit
- Leave 4 fuses (1A*2+2A+3A, all MDL) in the logger box
Tzu-Yi, Sarah1 jar of washer fluid left
59
06-06-2024- Pre-cleaning test
- Clean LI-7200 & LI-7700 mirrors, water probe
- Calibrate EC system & water probe (pH & DO)
- Measure WTH
- Swap USB stick, wildlife camera memory card and batteries
- desiccants: loggerbox*3, powerbox*2, pump, LI7550, converter box
- Refill washer unit
Tzu-Yi, Sarah2 jar of washer fluid left
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100