4
Arming/Disarming Event
5
6
Event TypeEvent descriptionContact ID CodeSIA Code
7
Hub Events
8
Malfunctionexternal power failureE301AT
9
Malfunction Restoreexternal power restoredR301AR
10
Malfunctionbattery lowE302YT
11
Malfunction Restorebattery chargedR302YR
12
Malfunctionlid openE145TA
13
Malfunction Restorelid closedR145TR
14
Malfunctionradio-frequency interference level is highE344XQ
15
Malfunction Restoreradio-frequency interference level is OKR344XH
16
AlarmHub is offline. Check mobile signal strength and the Ethernet portE350YC
17
Alarm RestoreHub is online againR350YK
18
Common Eventturned offE308ZZ
19
Common Event[device] was switched onE305ZY
20
Common Event[device] was reset to factory settingsE306XI
21
Common Eventupdating firmware...not send via CIDRB
22
Common Eventfirmware updatednot send via CIDRS
23
Malfunctionconnection to the monitoring station is lost. Check mobile signal strength and the Ethernet port on the HubR354YS
24
Malfunctionbattery missingE300YM
25
Malfunction Restorebattery connected after missingR300YA
26
not sent to the Appnew settingsE627YG
27
Malfunctionhigh level of interference at Wings frequenciesE344XQ
28
Malfunction Restoreinterference level at Wings frequencies is OKR344XH
29
Auto Arming Events
30
Arming/Disarming EventDisarmed automatically, scenario [scenario]E403OA
31
Arming/Disarming EventArmed automatically, scenario [scenario]R403CA
32
Arming/Disarming EventNight mode activated automatically, scenario [scenario]R403NC
33
Arming/Disarming Eventunsuccessful arming attempt, scenario [scenario]E455CC
34
Arming/Disarming Eventunsuccessful Night mode activation attempt, scenario [scenario]E455NE
35
Arming/Disarming EventThe system has been armed with malfunctions automatically, scenario [scenario]R403AF
36
Arming/Disarming EventNight mode activated with malfunctions automatically, scenario [scenario]R403NB
37
Arming/Disarming EventNight mode deactivated automatically, scenario [scenario]E403NO
38
Arming/Disarming Event[group] has been disarmed automatically, scenario [scenario]E403OB
39
Arming/Disarming Event[group] has been armed automatically, scenario [scenario]R403CB
40
Arming/Disarming Event[group] has been armed with malfunctions automatically, scenario [scenario]R403AF
41
Arming/Disarming Event[group] unsuccessful arming attempt, scenario [scenario]E455CD
42
Common Device Events
43
Malfunctionlid open, [device] in [room]E144TA
44
Malfunction Restorelid closed, [device] in [room]R144TR
45
Malfunctionlow battery, [device] in [room]E384XT
46
Malfunction Restorebattery charged, [device] in [room]R384XR
47
Malfunctionconnection lost, [device] in [room]E381XL
48
Malfunction Restoreconnection restored, [device] in [room]R381XC
49
GlassProtect
50
Alarmglass break detected, [device] in [room]E130BA
51
Alarmexternal contact open, [device] in [room]E130BA
52
Alarm Restoreexternal contact closed, [device] in [room]R130BR
53
LeakProtect
54
Alarmwater leak detected, [device] in [room]E154WA
55
Alarm Restoreno water leak detected, [device] in [room]R154WH
56
Malfunction[device] moved in [room]E144SM
57
MotionProtect & MotionProtect Plus
58
Alarmmotion detected, [device] in [room]E130BA
59
MotionProtect Outdoor
60
Alarmmotion detected, [device] in [room]E130BA
61
Malfunctionmasking detected, check the [device] in [room]E137TA
62
Malfunction Restoremasking is not detected, [device] in [room]R137TR
63
Malfunctionexternal power failure, [device] in [room]E337YP
64
Malfunction Restoreexternal power restored, [device] in [room]R337YQ
65
MotionProtect Curtain
66
Alarmmotion detected, [device] in [room]E130BA
67
Malfunctionmasking detected, check the [device] in [room]E137TA
68
Malfunction Restoremasking is not detected, [device] in [room]R137TR
69
MotionCam
70
Alarmmotion detected, [device] in [room]E130BA
71
Malfunction[device] in [room] has lost connection with hub over photos communication channelE391PF
72
Malfunction Restore[device] in [room] has restored connection with hub over photos communication channelR391PO
73
RangeExtender
74
Malfunctionexternal power failure, [device] in [room]E301AT
75
Malfunction Restoreexternal power restored, [device] in [room]R301AR
76
Common EventUpdaiting your [device] firmwarenot send via CIDRB
77
Common EventThe firmware of your [device] has updated successfullynot send via CIDRS
78
CombiProtect
79
Alarmmotion detected, [device] in [room]E130BA
80
Alarmglass break detected, [device] in [room]E130BA
81
FireProtect & FireProtect Plus
82
Alarmsmoke detected, [device] in [room]E111FA
83
Alarm Restoreno smoke detected, [device] in [room]R111FH
84
Alarmtemperature above the threshold value, [device] in [room]E114KA
85
Alarm Restoretemperature below the threshold value, [device] in [room]R114KH
86
Malfunctionhardware failure, [device] in [room]E389FT
87
Malfunction Restorereset after hardware failure, [device] in [room]R389FJ
88
Malfunctionsmoke chamber dirty, [device] in [room]E393FS
89
Malfunction Restoresmoke chamber clean, [device] in [room]R393FJ
90
Malfunctionlow reserve battery charge, [device] in [room]E384YT
91
Malfunction Restorereserve battery charged, [device] in [room]R384YR
92
Alarmrapid temperature rise detected, [device] in [room]E114KA
93
Alarm Restorerapid temperature rise stopped, [device] in [room]R114KH
94
Malfunctionfaulty detector [device] in [room]. Please, contact the service center listed in the warranty cardnot send via CIDFS
95
Malfunction Restorethe smoke chamber of [device] in [room] is OKnot send via CIDFX
96
AlarmCarbon monoxide (СО) detected, [device] in [room]E162GA
97
Alarm RestoreCarbon monoxide (CO) level is OK, [device] in [room]R162GH
98
Keypad
99
Arming/Disarming EventDisarmed using [device]E409OP
100
Arming/Disarming EventArmed using [device]R409CL