A | B | C | D | E | F | G | H | I | J | K | L | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | MOTOR | PROPELLER diameterXpitch | POWER SETTING | WATTS | AMPS | VOLTS | THRUST grams | THRUST ounces | SPECIFIC THRUST grams/watt | DENSITY ALTITUDE | ||
2 | ||||||||||||
3 | "POCKET ROCKET" | |||||||||||
4 | TURNIGY D2826-6 2200KV | 6x4 Master Airscrew | max | 305 | 25.5 | 12.4 nominal | 889 | 31 | 2.91 | 3100' measured | PREFERRED ALL-AROUND | |
5 | TURNIGY D2826-6 2200KV | mid | 200 | 17.9 | 12.4 nominal | 625 | 22 | 3.13 | 3100' measured | |||
6 | TURNIGY D2826-6 2200KV | low | 100 | 8.5 | 12.4 nominal | 360 | 13 | 3.60 | 3100' measured | |||
7 | TURNIGY D2826-6 2200KV | 6x3 Master Airscrew | max | 305 | 26.3 | 12.4 nominal | 990 | 35 | 3.25 | 3100' measured | ||
8 | TURNIGY D2826-6 2200KV | 6x3 Master Airscrew | low | 100 | 8.9 | 12.4 nominal | 380 | 13 | 3.80 | 3100' measured | ||
9 | TURNIGY D2826-6 2200KV | 6x4 APC | max | 335 | 27.4 | 12.4 nominal | 900 | 32 | 2.69 | 3100' measured | ||
10 | TURNIGY D2826-6 2200KV | 6x4 APC | low | 100 | 8.9 | 12.4 nominal | 390 | 14 | 3.90 | 3100' measured | ||
11 | TURNIGY D2826-6 2200KV | 5x5 APC | max | 256 | 22.0 | 12.4 nominal | 667 | 24 | 2.61 | 3100' measured | ||
12 | TURNIGY D2826-6 2200KV | 5x5 APC | low | 100 | 8.5 | 12.4 nominal | 315 | 11 | 3.15 | 3100' measured | ||
13 | ||||||||||||
14 | "THE WORKHORSE" | |||||||||||
15 | TURNIGY D2836-8 1100KV | 8x4 Master Airscrew | max | 105 | 8.6 | 12.4 nominal | 570 | 20 | 5.44 | 3440' measured | ||
16 | TURNIGY D2836-8 1100KV | mid | 49 | 4.0 | 12.4 nominal | 316 | 11 | 6.45 | 3440' measured | |||
17 | TURNIGY D2836-8 1100KV | 9x4 Master Airscrew | max | 155 | 12.6 | 12.4 nominal | 824 | 29 | 5.32 | 3440' measured | ||
18 | TURNIGY D2836-8 1100KV | mid | 99 | 8.1 | 12.4 nominal | 577 | 20 | 5.83 | 3440' measured | |||
19 | TURNIGY D2836-8 1100KV | low | 50 | 4.1 | 12.4 nominal | 333 | 12 | 6.66 | 3440' measured | |||
20 | TURNIGY D2836-8 1100KV | 10x5 Master Airscrew | max | 247 | 20.5 | 12.4 nominal | 1,171 | 41 | 4.74 | 3440' measured | ||
21 | TURNIGY D2836-8 1100KV | mid | 149 | 12.3 | 12.4 nominal | 822 | 29 | 5.52 | 3440' measured | |||
22 | TURNIGY D2836-8 1100KV | mid | 100 | 8.7 | 12.4 nominal | 592 | 21 | 5.92 | 3440' measured | |||
23 | TURNIGY D2836-8 1100KV | low | 49 | 4.0 | 12.4 nominal | 357 | 13 | 7.29 | 3440' measured | |||
24 | TURNIGY D2836-8 1100KV | 10x6 Master Airscrew | max | 253 | 21.0 | 12.4 nominal | 1,270 | 45 | 5.02 | 3440' measured | PREFERRED FOR SPEED | |
25 | TURNIGY D2836-8 1100KV | mid | 151 | 12.5 | 12.4 nominal | 872 | 31 | 5.77 | 3440' measured | |||
26 | TURNIGY D2836-8 1100KV | mid | 101 | 8.3 | 12.4 nominal | 612 | 22 | 6.06 | 3440' measured | |||
27 | TURNIGY D2836-8 1100KV | low | 50 | 4.1 | 12.4 nominal | 384 | 14 | 7.68 | 3440' measured | |||
28 | TURNIGY D2836-8 1100KV | 11x4 Master Airscrew | max | 259 | 21.6 | 12.4 nominal | 1,318 | 46 | 5.09 | 3440' measured | PREFERRED LOW-SPEED POWER | |
29 | TURNIGY D2836-8 1100KV | mid | 202 | 16.8 | 12.4 nominal | 1,065 | 38 | 5.27 | 3440' measured | |||
30 | TURNIGY D2836-8 1100KV | mid | 151 | 12.6 | 12.4 nominal | 887 | 31 | 5.87 | 3440' measured | |||
31 | TURNIGY D2836-8 1100KV | mid | 100 | 8.6 | 12.4 nominal | 647 | 23 | 6.47 | 3440' measured | |||
32 | TURNIGY D2836-8 1100KV | low | 50 | 4.1 | 12.4 nominal | 383 | 14 | 7.66 | 3440' measured | |||
33 | ||||||||||||
34 | TURNIGY D2836-8 1100KV | 8x3.8 SlowFly | max | 155 | 12.7 | 12.4 nominal | 724 | 26 | 4.67 | 3440' measured | ||
35 | TURNIGY D2836-8 1100KV | mid | 100 | 8.7 | 12.4 nominal | 551 | 19 | 5.51 | 3440' measured | |||
36 | TURNIGY D2836-8 1100KV | low | 51 | 4.2 | 12.4 nominal | 349 | 12 | 6.84 | 3440' measured | |||
37 | TURNIGY D2836-8 1100KV | 9x3.8 SlowFly | max | 189 | 15.8 | 12.4 nominal | 967 | 34 | 5.12 | 3440' measured | ||
38 | TURNIGY D2836-8 1100KV | mid | 151 | 12.6 | 12.4 nominal | 781 | 28 | 5.17 | 3440' measured | |||
39 | TURNIGY D2836-8 1100KV | mid | 101 | 8.4 | 12.4 nominal | 606 | 21 | 6.00 | 3440' measured | |||
40 | TURNIGY D2836-8 1100KV | low | 52 | 4.3 | 12.4 nominal | 389 | 14 | 7.48 | 3440' measured | |||
41 | TURNIGY D2836-8 1100KV | 9x6 SlowFly | max | 277 | 23.2 | 12.4 nominal | 1,110 | 39 | 4.01 | 3440' measured | ||
42 | TURNIGY D2836-8 1100KV | mid | 151 | 12.6 | 12.4 nominal | 727 | 26 | 4.81 | 3440' measured | |||
43 | TURNIGY D2836-8 1100KV | mid | 102 | 8.5 | 12.4 nominal | 542 | 19 | 5.31 | 3440' measured | |||
44 | TURNIGY D2836-8 1100KV | low | 52 | 4.3 | 12.4 nominal | 351 | 12 | 6.75 | 3440' measured | |||
45 | TURNIGY D2836-8 1100KV | 10x4.5 multirotor | max | 281 | 24.0 | 12.4 nominal | 1,308 | 46 | 4.65 | 3440' measured | ||
46 | TURNIGY D2836-8 1100KV | mid | 201 | 17.0 | 12.4 nominal | 1,039 | 37 | 5.17 | 3440' measured | |||
47 | TURNIGY D2836-8 1100KV | mid | 150 | 12.6 | 12.4 nominal | 813 | 29 | 5.43 | 3440' measured | |||
48 | TURNIGY D2836-8 1100KV | mid | 101 | 8.5 | 12.4 nominal | 615 | 22 | 6.09 | 3440' measured | |||
49 | TURNIGY D2836-8 1100KV | low | 50 | 4.2 | 12.4 nominal | 380 | 13 | 7.60 | 3440' measured | |||
50 | 0 | #DIV/0! | ||||||||||
51 | "THE POWERHOUSE" | 0 | #DIV/0! | |||||||||
52 | TURNIGY NTM 3536 1400KV | 10x4 Master Airscrew | 526 | 44 | 12.4 nominal | 2014 | 71 | 3.83 | 3600' measured | |||
53 | TURNIGY NTM 3536 1400KV | 403 | 33.8 | 12.4 nominal | 1649 | 58 | 4.09 | 3600' measured | ||||
54 | TURNIGY NTM 3536 1400KV | 301 | 25.1 | 12.4 nominal | 1423 | 50 | 4.73 | 3600' measured | ||||
55 | TURNIGY NTM 3536 1400KV | 205 | 17 | 12.4 nominal | 1072 | 38 | 5.23 | 3600' measured | ||||
56 | TURNIGY NTM 3536 1400KV | 102 | 8.4 | 12.4 nominal | 649 | 23 | 6.36 | 3600' measured | ||||
57 | TURNIGY NTM 3536 1400KV | 10x5 Master Airscrew | 590 | 50.4 | 12.4 nominal | 2104 | 74 | 3.57 | 3600' measured | |||
58 | TURNIGY NTM 3536 1400KV | 498 | 43 | 12.4 nominal | 1832 | 65 | 3.68 | 3600' measured | ||||
59 | TURNIGY NTM 3536 1400KV | 400 | 34 | 12.4 nominal | 1588 | 56 | 3.97 | 3600' measured | ||||
60 | TURNIGY NTM 3536 1400KV | 301 | 25.44 | 12.4 nominal | 1311 | 46 | 4.36 | 3600' measured | ||||
61 | TURNIGY NTM 3536 1400KV | 197 | 16.5 | 12.4 nominal | 983 | 35 | 4.99 | 3600' measured | ||||
62 | TURNIGY NTM 3536 1400KV | 100 | 8.3 | 12.4 nominal | 608 | 21 | 6.08 | 3600' measured | ||||
63 | TURNIGY NTM 3536 1400KV | 10x6 Master Airscrew | 590 | 50.8 | 12.4 nominal | 1768 | 62 | 3.00 | 3600' measured | PREFERRED SPEED | ||
64 | TURNIGY NTM 3536 1400KV | 501 | 43 | 12.4 nominal | 1708 | 60 | 3.41 | 3600' measured | ||||
65 | TURNIGY NTM 3536 1400KV | 394 | 33.7 | 12.4 nominal | 1391 | 49 | 3.53 | 3600' measured | ||||
66 | TURNIGY NTM 3536 1400KV | 302 | 25.6 | 12.4 nominal | 1201 | 42 | 3.98 | 3600' measured | ||||
67 | TURNIGY NTM 3536 1400KV | 200 | 16.8 | 12.4 nominal | 946 | 33 | 4.73 | 3600' measured | ||||
68 | TURNIGY NTM 3536 1400KV | 104 | 8.7 | 12.4 nominal | 593 | 21 | 5.70 | 3600' measured | ||||
69 | TURNIGY NTM 3536 1400KV | 11x4 Master Airscrew | 593 | 51.5 | 12.4 nominal | 2166 | 76 | 3.65 | 3600' measured | PREFERRED EFFICIENCY | ||
70 | TURNIGY NTM 3536 1400KV | 594 | 42.7 | 12.4 nominal | 2120 | 75 | 3.57 | 3600' measured | ||||
71 | TURNIGY NTM 3536 1400KV | 404 | 34.8 | 12.4 nominal | 1708 | 60 | 4.23 | 3600' measured | ||||
72 | TURNIGY NTM 3536 1400KV | 301 | 25.7 | 12.4 nominal | 1404 | 50 | 4.66 | 3600' measured | ||||
73 | TURNIGY NTM 3536 1400KV | 202 | 17.1 | 12.4 nominal | 955 | 34 | 4.73 | 3600' measured | ||||
74 | TURNIGY NTM 3536 1400KV | 102 | 8.6 | 12.4 nominal | 642 | 23 | 6.29 | 3600' measured | ||||
75 | TURNIGY NTM 3536 1400KV | 11x5 Master Airscrew | 651 | 57 | 12.4 nominal | 2092 | 74 | 3.21 | 3600' measured | |||
76 | TURNIGY NTM 3536 1400KV | 498 | 43.5 | 12.4 nominal | 1909 | 67 | 3.83 | 3600' measured | ||||
77 | TURNIGY NTM 3536 1400KV | 399 | 34.7 | 12.4 nominal | 1693 | 60 | 4.24 | 3600' measured | ||||
78 | TURNIGY NTM 3536 1400KV | 303 | 26.2 | 12.4 nominal | 1421 | 50 | 4.69 | 3600' measured | ||||
79 | TURNIGY NTM 3536 1400KV | 209 | 17.2 | 12.4 nominal | 1092 | 39 | 5.22 | 3600' measured | ||||
80 | TURNIGY NTM 3536 1400KV | 99 | 8.4 | 12.4 nominal | 674 | 24 | 6.81 | 3600' measured | ||||
81 | TURNIGY NTM 3536 1400KV | 11x6 Master Airscrew | 672 | 59.9 | 12.4 nominal | 2174 | 77 | 3.24 | 3600' measured | |||
82 | TURNIGY NTM 3536 1400KV | 499 | 44.2 | 12.4 nominal | 1807 | 64 | 3.62 | 3600' measured | ||||
83 | TURNIGY NTM 3536 1400KV | 392 | 34.4 | 12.4 nominal | 1794 | 63 | 4.58 | 3600' measured | ||||
84 | TURNIGY NTM 3536 1400KV | 285 | 24.8 | 12.4 nominal | 1240 | 44 | 4.35 | 3600' measured | ||||
85 | TURNIGY NTM 3536 1400KV | 209 | 18.1 | 12.4 nominal | 1238 | 44 | 5.92 | 3600' measured | ||||
86 | TURNIGY NTM 3536 1400KV | 100 | 8.9 | 12.4 nominal | 670 | 24 | 6.70 | 3600' measured | ||||
87 | TURNIGY NTM 3536 1400KV | 8x6x3 Master Airscrew | 504 | 42 | 12.4 nominal | 1660 | 59 | 3.29 | 3600' measured | |||
88 | TURNIGY NTM 3536 1400KV | 403 | 33.8 | 12.4 nominal | 1586 | 56 | 3.94 | 3600' measured | ||||
89 | TURNIGY NTM 3536 1400KV | 298 | 24.8 | 12.4 nominal | 1154 | 41 | 3.87 | 3600' measured | ||||
90 | TURNIGY NTM 3536 1400KV | 201 | 16.6 | 12.4 nominal | 917 | 32 | 4.56 | 3600' measured | ||||
91 | TURNIGY NTM 3536 1400KV | 100 | 8.2 | 12.4 nominal | 473 | 17 | 4.73 | 3600' measured | ||||
92 | TURNIGY NTM 3536 1400KV | 10x7x3 Master Airscrew | 764 | 66.4 | 12.4 nominal | 1985 | 70 | 2.60 | 3600' measured | |||
93 | TURNIGY NTM 3536 1400KV | 597 | 51.7 | 12.4 nominal | 1881 | 66 | 3.15 | 3600' measured | ||||
94 | TURNIGY NTM 3536 1400KV | 473 | 41 | 12.4 nominal | 1797 | 63 | 3.80 | 3600' measured | ||||
95 | TURNIGY NTM 3536 1400KV | 397 | 33.9 | 12.4 nominal | 1444 | 51 | 3.64 | 3600' measured | ||||
96 | TURNIGY NTM 3536 1400KV | 310 | 26.3 | 12.4 nominal | 1176 | 41 | 3.79 | 3600' measured | ||||
97 | TURNIGY NTM 3536 1400KV | 195 | 16.4 | 12.4 nominal | 865 | 31 | 4.44 | 3600' measured | ||||
98 | 104 | 8.6 | 12.4 nominal | 554 | 20 | 5.33 | 3600' measured | |||||
99 | ||||||||||||
100 | EDF 3600 kV inrunner | 64mm EDF | max | 350 | 19.8 | 12 measured | 520 | 18 | 2.21 | 2800' nominal |