Team Phoenix - 2011 Robot
3
Air Compressor Temperature Comparisons
4
5
ReadingTemperature (C)Temperature (F)Notes:
6
EnvironmentalAll tests performed on a VIAIR 00090 air compressor setup in a FRC-legal configuration.
7
Ambient Temp2781
8
Static Compressor Temp2886
9
w/o Fan (C)w/ Fan (C)w/o Fan (F)w/ Fan (F)
10
Idle Temp29288583All tests done with a fan used a 120mm computer fan included in the 2011 FRC kit of parts.
11
Running (one full charge)5446130115
12
1min After Running433411093
13
2min After Running423010886
14
3min After Running392810282The pneumatic systems air storage consisted of three 16.0 Cubic Inch Volume Clippard Air Tanks.
15
4min After Running382810082
16
5min After Running36289782
17
18
Fan was mounted to blow across the compressor's long side to maximise surface area.