A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | ZB Device ID | ZB Profile | Device Friendly Name | Status | Manufacturer | Device Model | ZB4O version | ZigBee Network Interface Controller (ZIC) | ZIC role | ZIC Firmware Version | Compilation Flags | Security | Implemented Clusters | Recognized Clusters | Comments | Tester(s) | ||||||||||
2 | 0x0009 | 0x0104 HA | Netvox Z800 - Mains Power Outlet | seems ok | Netvox | Z800 | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Identify 0x0003, Group 0x0004, Scene 0x0005, OnOff 0x0006, Meter 0x0702 (proprietary) | Basic 0x0000, Identify 0x0003, Group 0x0004, Scene 0x0005, OnOff 0x0006, Meter 0x0702 (proprietary) | MB | |||||||||||
3 | 0x0302 | 0x0104 HA | Netvox Z711 - Wireless Temperature & Humidity Sensor | seems ok | Netvox | Z711 | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, Humidity M. 0x0405, Temperature M. 0x0402, Alarms 0x0009 | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, Humidity M. 0x0405, Temperature M. 0x0402, Alarms 0x0009 | MB | |||||||||||
4 | 0x0000 | 0x0104 HA | Netvox ZB02C - 3 gang switch | pending | Netvox | ZB02C | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Identify 0x0003, On/Off 0x0006, OnOff Switch Configuration 0x0007 (optional) | Basic 0x0000, Identify 0x0003, On/Off 0x0006, OnOff Switch Configuration 0x0007 Power Configuration 0x0001 | clusters mismatch | MB | ||||||||||
5 | 0x0402 | 0x0104 HA | Netvox ZB01A - CIE IR motion detector | seems ok | Netvox | ZB01A | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Identify 0x0003, IAS Zone 0x0500, Power Configuration 0x0001 (optional), Alarms 0x0009 (optional) | Basic 0x0000, Identify 0x0003, IAS Zone 0x0500, Power Configuration 0x0001, Alarms 0x0009 | MB | |||||||||||
6 | 0x0107 | 0x0104 HA | Netvox ZB01D - motion detector | seems ok | Netvox | ZB01D | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, Commissioning 0x0015, Occupancy sensing 0x0406 | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, Commissioning 0x0015, Occupancy sensing 0x0406 | MB | |||||||||||
7 | 0x0001 - 0x0401 | 0x0104 HA | Netvox Z501A - Remote Controller | TBD | Netvox | Z501A | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | [no info] | [as 0x0001]: Basic 0x0000, Power configuration 0x0001, Identify 0x0003, Alarms 0x0009, On/Off 0x0006, Level Control 0x0008 [as 0x0401]: Basic 0x0000, Identify 0x0003, IAS ACE 0x0501 | MB | |||||||||||
8 | 0x0403 | 0x0104 HA | Netvox Z601A - Warning Device | seems ok | Netvox | Z601A | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Identify 0x0003, IAS WD 0x0502 | Basic 0x0000, Identify 0x0003, IAS WD 0x0502 | MB | |||||||||||
9 | 0x0402 | 0x0104 HA | Netvox Z307 - Fall Sensor | seems ok | Netvox | Z307 | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Identify 0x0003, IAS Zone 0x0500, IAS Cluster 0x0E40 (proprietary) | Basic 0x0000, Identify 0x0003, IAS Zone 0x0500 | MB | |||||||||||
10 | 0x0402 | 0x0104 HA | Netvox ZA02E - Smoke Detector with Heat Sensor | seems ok | Netvox | ZA02E | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, IAS Zone 0x0500 | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, IAS Zone 0x0500 | MB | |||||||||||
11 | 0x0106 | 0x0104 HA | Netvox Z302G - Light Sensor | seems ok | Netvox | Z302G | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Identify 0x0003, Illuminance Measurement 0x0400 | Basic 0x0000, Identify 0x0003, Illuminance Measurement 0x0400 | MB | |||||||||||
12 | 0x0402 | 0x0104 HA | Netvox Z302A - Door Contact Sensor | seems ok | Netvox | Z302A | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Identify 0x0003, IAS Zone 0x0500, Netvox IAS Cluster 0x0E40 (proprietary) | Basic 0x0000, Identify 0x0003, IAS Zone 0x0500 | MB | |||||||||||
13 | 0x0103 | 0x0104 HA | Netvox Z302B - Light Sensor Switch | seems ok | Netvox | Z302B | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Identify 0x0003, On/Off 0x0006, Netvox MIX Cluster 0x0E60 (proprietary) | Basic 0x0000, Identify 0x0003, On/Off 0x0006 | MB | |||||||||||
14 | 0x0402 | 0x0104 HA | Netvox Z302D - CIE Emergency Button | seems ok | Netvox | Z302D | 0.01.00 | TI CC2531DK v2.1 | Coordinator | 2.5.1a | SE_PROFILE | no | Basic 0x0000, Identify 0x0003, IAS Zone 0x0500, Netvox IAS Cluster 0x0E40 (proprietary) | Basic 0x0000, Identify 0x0003, IAS Zone 0x0500 | MB | |||||||||||
15 | Netvox Z817A - Ceiling Mounted Switch unit with Consumption Display | Netvox | Z817A | [TODO] only works when directly connected to electrical grid | MB | |||||||||||||||||||||
16 | 0x0009 | 0x0104 HA | ZBMLC15 - Mains Power Outlet | seems ok (some commands are not handled correctly by the Tester interface) | Compacta (OEM=NetVox), supplied by SimpleHomeNet | ZBMLC15 | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Basic 0x0000, Identify 0x0003, Group 0x0004, Scene 0x0005, OnOff 0x0006, Meter 0x0702 (proprietary) | Basic 0x0000, Identify 0x0003, Group 0x0004, Scene 0x0005, OnOff 0x0006, | SimpleHomeNet documentation lists this device as a ON/OFF Light with device ID = 0x0100. The stack of the device I tested contained a bug. I was able to update the device by means of CC Debugger (with a special cable) and a hex file supplied by SimpleHomeNet | HA | ||||||||||
17 | 0x0302 | 0x0104 HA | ZBHT-1 - Wireless Temperature & Humidity Sensor | seems ok (some commands are not handled correctly by the Tester interface) | Compacta (OEM=NetVox), supplied by SimpleHomeNet | ZBHT-1 | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, Humidity M. 0x0405, Temperature M. 0x0402, Alarms 0x0009 | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, Temperature M. 0x0402, Alarms 0x0009 | 1) Reporting can not be configured. 2) The resetAllAlarms command returns a "Unsupported general Command". As this command is mandatory, it is a bug in the device. | HA | ||||||||||
18 | 0x0000 | 0x0104 HA | ZBWS3B - 3 gang switch | seems ok (some commands are not handled correctly by the Tester interface) | Compacta (OEM=NetVox), supplied by SimpleHomeNet | ZBWS3B | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Basic 0x0000, Identify 0x0003, On/Off 0x0006, OnOff Switch Configuration 0x0007 (optional) | Basic 0x0000, Identify 0x0003, On/Off 0x0006, OnOff Switch Configuration 0x0007 | HA | |||||||||||
19 | 0x0009 | 0x0104 HA | Z808A - Power Socket with Power consumption monitoring | Some clusters not expanded | Netvox | Z808A | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Basic 0x0000, Identify 0x0003, Group 0x0004, Scene 0x0005, OnOff 0x0006, Commission 0x0015, Simple Metering 0x0702 (proprietary) | Basic 0x0000, Identify 0x0003, Group 0x0004, Scene 0x0005, OnOff 0x0006 | Commissioning cluster (0x0015) not recognized, Simple Metering (0x0702) is propriety cluster NetVox | HA | ||||||||||
20 | 0x0402, 0x0000, 0x0302 | 0x0104 HA | ZB01C - Motion Detector, On/Off Switch, Temperature sensor | Motion Detection requires registration to security system | Netvox | ZB01C | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Motion Detector: ??? On/Off Switch: Basic 0x0000, Identify 0x0003, Power Configuration 0x0001, Alarms 0x0009 Temperature Sensor: Basic, Power Configuration, Identify, Alarms, Temperature Measurement | On/Off Switch: Basic 0x0000, Identify 0x0003, Power Configuration 0x0001, Alarms 0x0009 Temperature Sensor: Basic, Power Configuration, Identify, Alarms, Temperature Measurement | Netvox/Zigbee specification also indicates (mandatory) the On/off Switch Configuration cluster (0x0007) for the On/Off switch. Not found! | HA | ||||||||||
21 | 0x0001, 0x0000 | 0x0104 HA | Z501C - Level Control Switch, OnOff Switch | Netvox | Z501C | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Level Control Switch: Basic, Power Configuration, Identify, OnOffSwitch Configuration, Groups, Scenes, Alarms, Commissioning OnOff Switch: Basic, Power Configuration, Identify, OnOffSwitch Configuration, Alarms, Commissioning | Level Control Switch: Basic, Power Configuration, Identify, OnOffSwitch Configuration, Groups, Scenes, Alarms OnOff Switch: Basic, Power Configuration, Identify, OnOffSwitch Configuration, Alarms | Commissioning cluster (0x0015) not recognized | HA | |||||||||||
22 | 0x0101 | 0x0104 HA | Z815M - Dual Dimmable Light (with local control) | Netvox | Z815M | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Basic, Identify, Groups, Scenes, OnOff, Level Control, Commisioning, Simple Metering (0x0702) | Basic, Identify, Groups, Scenes, OnOff, Level Control | Commissioning cluster (0x0015) not recognized, Simple Metering (0x0702) is propriety cluster NetVox. The commands of the Level Cluster do not generate a default response command. | HA | |||||||||||
23 | 0x0002 | 0x0104 HA | Z817C - OnOff Output (with PIR switch) | Netvox | Z817C | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Basic, Identify, Groups, Scenes, OnOff, Commissioning, Simple Metering (0x0702) | Basic, Identify, Groups, Scenes, OnOff | Commissioning cluster (0x0015) not recognized, Simple Metering (0x0702) is propriety cluster NetVox. Strange PIR function; As long as there is no movement detected, the light "listenes" to Zigbee commands. As soon as movement is detected, the PIR function takes over. | HA | |||||||||||
24 | 0x0002 | 0x0104 HA | Z802 - Dual OnOff Output | Netvox | Z802 | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Basic, Identify, Groups, Scenes, OnOff | Basic, Identify, Groups, Scenes, OnOff | |||||||||||||
25 | 0x0000 | 0x104 HA | Z801T - 5 * OnOff Switch | Netvox | Z801T | 0.01.00 revision 575 | TI CC2531DK v2.1 | Coordinator | 2.05.00 | SE_PROFILE | yes, using standard HA Trust Center Link Key | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, On/Off 0x0006, OnOff Switch Configuration 0x0007 | Basic 0x0000, Power Configuration 0x0001, Identify 0x0003, On/Off 0x0006, OnOff Switch Configuration 0x0007 | HA | ||||||||||||
26 | ||||||||||||||||||||||||||
27 | ||||||||||||||||||||||||||
28 | ||||||||||||||||||||||||||
29 | ||||||||||||||||||||||||||
30 | ||||||||||||||||||||||||||
31 | ||||||||||||||||||||||||||
32 | ||||||||||||||||||||||||||
33 | ||||||||||||||||||||||||||
34 | ||||||||||||||||||||||||||
35 | ||||||||||||||||||||||||||
36 | ||||||||||||||||||||||||||
37 | ||||||||||||||||||||||||||
38 | ||||||||||||||||||||||||||
39 | ||||||||||||||||||||||||||
40 | ||||||||||||||||||||||||||
41 | ||||||||||||||||||||||||||
42 | ||||||||||||||||||||||||||
43 | ||||||||||||||||||||||||||
44 | ||||||||||||||||||||||||||
45 | ||||||||||||||||||||||||||
46 | ||||||||||||||||||||||||||
47 | ||||||||||||||||||||||||||
48 | ||||||||||||||||||||||||||
49 | ||||||||||||||||||||||||||
50 | ||||||||||||||||||||||||||
51 | ||||||||||||||||||||||||||
52 | ||||||||||||||||||||||||||
53 | ||||||||||||||||||||||||||
54 | ||||||||||||||||||||||||||
55 | ||||||||||||||||||||||||||
56 | ||||||||||||||||||||||||||
57 | ||||||||||||||||||||||||||
58 | ||||||||||||||||||||||||||
59 | ||||||||||||||||||||||||||
60 | ||||||||||||||||||||||||||
61 | ||||||||||||||||||||||||||
62 | ||||||||||||||||||||||||||
63 | ||||||||||||||||||||||||||
64 | ||||||||||||||||||||||||||
65 | ||||||||||||||||||||||||||
66 | ||||||||||||||||||||||||||
67 | ||||||||||||||||||||||||||
68 | ||||||||||||||||||||||||||
69 | ||||||||||||||||||||||||||
70 | ||||||||||||||||||||||||||
71 | ||||||||||||||||||||||||||
72 | ||||||||||||||||||||||||||
73 | ||||||||||||||||||||||||||
74 | ||||||||||||||||||||||||||
75 | ||||||||||||||||||||||||||
76 | ||||||||||||||||||||||||||
77 | ||||||||||||||||||||||||||
78 | ||||||||||||||||||||||||||
79 | ||||||||||||||||||||||||||
80 | ||||||||||||||||||||||||||
81 | ||||||||||||||||||||||||||
82 | ||||||||||||||||||||||||||
83 | ||||||||||||||||||||||||||
84 | ||||||||||||||||||||||||||
85 | ||||||||||||||||||||||||||
86 | ||||||||||||||||||||||||||
87 | ||||||||||||||||||||||||||
88 | ||||||||||||||||||||||||||
89 | ||||||||||||||||||||||||||
90 | ||||||||||||||||||||||||||
91 | ||||||||||||||||||||||||||
92 | ||||||||||||||||||||||||||
93 | ||||||||||||||||||||||||||
94 | ||||||||||||||||||||||||||
95 | ||||||||||||||||||||||||||
96 | ||||||||||||||||||||||||||
97 | ||||||||||||||||||||||||||
98 | ||||||||||||||||||||||||||
99 | ||||||||||||||||||||||||||
100 |