1
MAYURBHANJ SCHOOL OF ENGINEERING
AY-2021-2022
DEPARTMENT OF ELECTRICAL ENGINEERING
5TH SEM
SUB-(EC-II)
TOPIC
.SYNCHRONOUS MOTOR.
PREPARED BY
ER.S.BARIK
Synchronous Motor
2
Synchronous Motor- Intro
3
Synchronous Motor-Principle
4
The rotor acting as a bar magnet will turn to line up with the rotating magnet field. The rotor gets locked to the RMF and rotates unlike induction motor at synchronous speed under all load condition
Changing The Load
5
An increase in the load will cause the rotor to lag the stator field but still maintain synchronous speed. Increase in load has increased the torque component, but the field strength has decreased due to the increase in length of the air gap between the rotor and the stator.
If the synchronous motor is overloaded it pulls out of synchronism and comes to rest. The minimum amount of torque which causes this is called the “ pull out torque”.
Lightly loaded motor
Heavily loaded motor
Starting Torque
6
Improvement of starting torque
7
Synchronous Machine Construction
8
Torque versus Speed
9
Summary
The synchronous motor:
10
Maintenance Practices-A.C. Motors
Clean, but don’t forget to inspect before and after cleaning
Check electrical connections for security, the insulation to be in satisfactory condition.
Examine for signs of over heating
Check that the motor is secure
Do an audible check
Ensure that the motor is not over heating when operating, a rule of thumb is that if it is too hot for the hand, it is too high.
When replacing a motor always ensure that the load, valve has not seized.
Also ensure that the motor operates in the correct direction
End of Motors
11