www.techtionsmart.com
您可依赖的低碳环保显示终端解决方案合作伙伴!
深圳市泰信智能电子有限公司
2025公司简介
www.techtionsmart.com
Shenzhen Techtion Smart Electronics Co., Ltd
Choosing the Right Display and Panel PC for Industrial Equipment
A Practical Selection Guide for Equipment Makers and System Integrators
Display | Platform | Mounting | Long-Term Supply
Webinar Date: Oct. 16, 2026 | 17:30-18:30 (GMT+8)
Techtion Smart Online Webinar
Choosing the Right Display and Panel PC for Industrial Equipment
Key Topics
📅 Date: Oct. 16, 2026 | 17:30-18:30 (GMT+8)
Speaker
Jason Zheng
Sales Engineer - Industrial & Embedded
Opening Introduction
Self-introduction
Jason Zheng
Sales Engineer – Industrial & Embedded
Techtion Smart
Focused on industrial monitors and Panel PCs for equipment makers
Working with overseas customers on custom display and HMI projects
Supporting projects from spec definition to sample and mass production
The purpose of this webinar
1. Share a practical way to choose brightness, bonding, touch and power for industrial equipment.
2. Compare AD board monitor, ARM Panel PC and x86 Panel PC, and how each is mounted.
3. Show how Techtion Smart supports custom projects from prototype to long-term supply.
Catalog
A practical webinar path from display selection to platform choice and long-term supply
Shenzhen Techtion Smart Electronics Co., Ltd
www.techtionsmart.com
2
01
About Techtion Smart
Company background, product lines and JDM / ODM capability
02
Display
Brightness, optical bonding, touch and power supply
03
Platform & Mounting
ARM or x86, OS choice, mounting, sealing and connectors
04
Prototype → Long-Term Supply
EMC, I/O customization, reliability test, EOL and BOM control
05
Project & Product References
Industrial projects and standard product platforms
06
Selection Checklist & Q&A
Key questions for your next project and open discussion
Techtion Smart Online Webinar
Catalog
www.techtionsmart.com
TECHTION
SMART
01
About Techtion Smart
Industrial display and Panel PC capability
built on Leadtek display manufacturing since 2015.
About Techtion Smart
Leadtek display manufacturing since 2015 · Techtion Smart complete-unit division, founded 2024
2015
Leadtek founded, display manufacturer
30,000 m²
Factory area
In-house
Engineering and reliability test lab
30+
Patents
Leadtek holds ISO 9001 / ISO 14001 / ISO 13485 / IATF 16949
Techtion Smart: complete-unit division of Leadtek, founded 2024
Product Lines
Industrial Monitor
Industrial Panel PC (ARM & x86)
Stainless Steel Series
ODM
OEM
Service Commitment
Quotation < 24H
Project evaluation < 48H
Sample lead time < 6 weeks
Production lead time < 8 weeks
8D report < 7 days
Techtion Smart Online Webinar
About Techtion Smart
www.techtionsmart.com
TECHTION
SMART
02
Display Selection
What decides whether an operator can read and use the screen on the machine.
Four Industrial Environments
Each environment puts different demands on the display
Techtion Smart Online Webinar
Industrial Environments
www.techtionsmart.com
Food & Pharma Wash-down
• Hot, high-pressure cleaning
• Stainless, fully sealed housing
• Touch that ignores water
• IP65/IP66/IP67
• Waterproof Circular Connector
Mobile Machinery & Agriculture
• Vibration and shock
• 12/24V vehicle power transients
• Sunlight in the cab
Lab & Medical Instruments
• Built into the device front
• 24/7 operation
• Gloved operation, easy to clean
·Front panel lP65
• Support :DC9V-DC36V
• Industrial Terminal Block
Connector
Outdoor EV Charging
• Direct sunlight
• Heat build-up behind the glass
• Impact and vandalism
• IP65/IK10
Start from the environment, then choose brightness, bonding, touch and power
Brightness: Match the Environment
Start from where the machine is used, then pick the brightness level
Environment | Typical Brightness | Techtion Option |
Indoor cabinet or control room | 350–500 nits | J Series Monitor & Panel PC (standard) |
Bright factory floor, near windows | 1000 nits | Stainless Panel PC / Monitor (TS-156PCBX, TS-215PCBX, TS-190MCBX) |
Strong ambient light, semi-outdoor machinery | 1500 nits | TS-185MCBX |
Direct sunlight, outdoor equipment | Local dimming 2000-3500 nits | TS-215THDL |
Automatic brightness with light sensor available
Techtion Smart Online Webinar
Brightness
www.techtionsmart.com
Readability: More Than Brightness
Contrast and surface treatment matter as much as nits
Techtion Smart Online Webinar
Readability
www.techtionsmart.com
Three ways to see the screen better
1 Brightness: more nits help, but add power and heat
2 Contrast: sunlight reflected by the glass turns black into grey; bonding and AR cut it
3 Surface: AG diffuses glare, AR reduces reflection, AF resists fingerprints
Same 1000-nit screen in strong sunlight
Contrast without help: about 1.8 : 1
Double the brightness
about 2.6 : 1
Bonding + AR
about 3.5 : 1
Cutting reflection beats doubling brightness, with no extra heat.
Environment | Brightness | Bonding | Surface treatment |
Control room, inside a cabinet | 350–500 nits | Air bonding is fine | Optional AG |
Bright factory floor, near windows | About 1000 nits | Optical bonding recommended | AG |
Outdoor, direct sunlight | 1500–2000+ nits | Optical bonding | AR, can be combined with AG |
Oily hands, frequent touch, wash-down | By site: 350–2000+ nits | As the site needs | Add AF for easy cleaning |
Trade-off: AG adds a slight haze and softens sharpness; AR cuts reflection but shows fingerprints more. No single coating fits every site.
Contrast values calculated for about 85,000 lux, 4.5% vs 1.5% reflectance, 1000:1 native contrast. Reflection: about 4% per glass-air surface (Fresnel equations).
Optical Bonding
Bonding decides reflection, fogging and outdoor readability
Techtion Smart Online Webinar
Optical Bonding
www.techtionsmart.com
| Air bonding (frame tape) | Optical bonding: OCA | Optical bonding: OCR |
What it is | Tape frame, air gap inside | Solid adhesive film | Liquid resin, cured by UV |
Extra internal reflection | About 8% (two glass-air surfaces) | Almost none | Almost none |
Fogging / dust inside | Possible | None | None |
Best for | Indoor, low cost, easy repair | Small to mid sizes, flat glass, high volume | Large sizes, thick or uneven glass, outdoor |
OCA or OCR?
Both remove the air gap and reflect about the same. OCA suits flat glass in small to mid sizes; OCR fills uneven or thick glass and large sizes.
More than readability
With the gap filled, nothing can fog or collect dust inside, and the glass is supported by the panel behind it, so the front is stronger and touch is more precise.
Reflection: about 4% per glass-air surface (Fresnel equations). Bonded layers are index-matched to glass, so the internal reflection nearly disappears; only the outer surface remains (reduce it with AR).
Cover Glass: Thickness and Process
Choose the thickness by impact risk, then the process by how the front is used
Techtion Smart Online Webinar
Cover Glass
www.techtionsmart.com
Thickness by environment (typical)
Environment | Glass thickness | Typical IK | Notes |
Indoor cabinet, lab | About 1.8-2 mm | No special need | Tempered glass is enough |
Factory HMI, tools and carts nearby | About 2-3 mm | About IK07 | Thicker glass needs touch tuning |
Outdoor, public, heavy impact | About 4-6 mm | IK08-IK10 | Laminated glass keeps pieces in place |
Processing options
Larger screens need thicker glass or more support for the same IK level.
Pencil hardness (e.g. 7H) rates scratch resistance of the surface, not impact strength. Ask for both.
Thickness-IK values are approximate and depend on glass type, bonding and housing (industry design guides). Pencil hardness per ASTM D3363. Surface coatings (AG / AR / AF): see Readability page.
Process | Options | When to use it | Why |
Strengthening | Chemical or thermal tempering | Chemical: thin glass on HMIs; thermal: thick outdoor glass | Stronger against impact and heat shock |
Edge finish | C chamfer, R corners, 2.5D | C chamfer where hands touch the edge; 2.5D for food and medical fronts | No sharp edges; a flush front has no step where dirt collects |
Printing | Black border, logo, IR ink window | All fronts; IR window when a light sensor sits behind the glass | Hides the frame and adhesive; IR ink lets the sensor see through |
Cut-outs | Holes or notches for buttons, sensors | Only when physical buttons or sensors are needed | Each hole weakens the glass: keep it away from edges |
Anti-shatter | Laminated glass or safety film | Outdoor and public sites; food plants | Broken pieces stay in place, no glass in the product |
Temperature: What the Datasheet Numbers Mean
Liquid crystal is sensitive to both heat and cold
Techtion Smart Online Webinar
Temperature and Lifetime
www.techtionsmart.com
1
Heat: Clearing Point
Above the clearing point (TNI) the LCD turns black
Standard panels: can black out around 70-90°C (varies)
High-TNI panels: rated up to about 110°C
Sun load + backlight heat behind sealed glass can reach it
2
Cold: Slow Response
Liquid crystal thickens in the cold
Below about -20°C, switching slows from ms to seconds
Heaters or warm-up time for cold sites
3
Operating vs Storage
Storage range is typically 10-20°C wider
e.g. operating -20~70°C, storage -30~80°C
Check the operating range for your site
4
Backlight "50,000 h"
Rated life = time to 50% brightness, usually at 25°C
Heat shortens LED life
Auto dimming extends it
Sources: Riverdi "LCD temperature range"; Marvel Technology "Outdoor LCD Display Blackening"; LCD module datasheets (LED life at Ta=25°C)
Touch Selection
PCAP, resistive or no touch: decide by gloves, water and stylus
| PCAP (G+G, 10-point) | Resistive (RTP) | No Touch |
Multi-touch | 10-point | Single point | - |
Glove operation | Tuned glove touch (EETI IC) | Any stylus or thick glove | - |
Wet surface | Waterproof touch tuning | Works | - |
Typical use | Wet and gloved work, multi-touch UI | Thick gloves, stylus, high-EMI sites (drives, motors) | Display only |
Touch firmware can be tuned per project (glove thickness, water rejection)
Techtion Smart Online Webinar
Touch Selection
www.techtionsmart.com
Why water, gloves and noise are tricky for PCAP
Water changes the capacitance much like a light finger, so it can trigger false touches; good controllers tell them apart. A glove adds distance, so the signal gets weaker. Electrical noise from drives and motors can disturb PCAP, while resistive touch is not affected. Always test with the real glove on the real machine.
Power Supply
Start from the power your machine already has
Techtion Smart Online Webinar
Power Supply
www.techtionsmart.com
1
Control cabinet, 24V DC
Most factory machines run a 24V DC supply. Choose a 24V or 9-36V input so no extra adapter is needed.
2
Long cables, motors, relays
Dips and spikes on the supply line are common. A wide 9-36V input with surge protection tolerates them.
3
Stand-alone unit, mains
Use an AC 100-240V input or an external adapter. Check plug, earthing and approvals for the target country.
9-36V covers the range, not the spikes
A wide input accepts both 12V and 24V systems, but factory power also carries short spikes from motors, relays and long cable runs.
Ask for surge and burst protection (IEC 61000-4-5 / 61000-4-4), and a hold-up option if the HMI must ride through short drops.
Define power early. It decides connector, cable and EMC design.
Sources: IEC 61000-4-4 (electrical fast transient / burst), IEC 61000-4-5 (surge).
TECHTION
SMART
03
Platform and Mounting
AD board monitor, ARM or x86 Panel PC, and how the unit fits into the equipment.
How to Choose: Decision Flow
Three questions, then match the software load to the platform
Techtion Smart Online Webinar
Decision Flow
www.techtionsmart.com
Already have a host PC or PLC?
Monitor + AD board
Yes
No
Any software, driver or SDK that runs only on Windows?
x86 Panel PC
Yes
No
Vision, 3D, a database or several apps at once?
x86 Panel PC
Yes
No
ARM Panel PC
lower cost, lower power
| ARM Panel PC | x86 Panel PC |
Typical software | One dedicated HMI app, web UI, Qt or Android app | Existing Windows software, SCADA client, database, several apps |
Typical chips | Rockchip RK3568 (4-core) / RK3588 (8-core) | Intel Celeron J6412 (4-core), Core i5 / i7 |
Power and cost | Low power, easy fanless design, lower cost | More power and heat, higher cost |
Watch out | Drivers must exist for Linux / Android; Android version follows the chip vendor | For long-life machines use Windows IoT Enterprise LTSC (about 10 years of support) |
One dedicated app → ARM. Windows-only or heavy computing → x86.
Chip data: Rockchip RK3568 / RK3588 public specs, Intel ARK (J6412). Windows IoT Enterprise LTSC lifecycle: Microsoft. Chip specs, not unit benchmarks.
When to Choose ARM or x86
Find your machine in the table, then pick the side
Techtion Smart Online Webinar
ARM or x86
www.techtionsmart.com
| Choose ARM | Choose x86 |
Your software | New software, or a web page, Android app or Qt interface | Existing Windows software that cannot be rewritten |
What it does | One dedicated operator screen: status, settings, alarms | Machine vision, camera inspection, 3D, local database, several programs at once |
Your device | Fanless, low power, fully sealed (wash-down, outdoor) | Needs Windows-only drivers, license dongles or device SDKs |
Typical examples | Packaging machine HMI, EV charger screen, farm machinery terminal, instrument front panel | Vision inspection station, SCADA operator station, MES terminal |
Rule of thumb: if your software already runs on a Windows PC and cannot be rewritten, choose x86.
If you are building new software, ARM is usually enough, at lower cost and power.
Mounting Options
Match the mounting to the machine front and the cleaning routine
Techtion Smart Online Webinar
Mounting Options
www.techtionsmart.com
Mounting | Typical place | What to watch |
Panel mount (embedded) | Machine front, cabinet door | Front IP65 depends on cut-out and gasket; the rear sits in the cabinet, so plan for heat |
Open frame | Inside your own enclosure | No housing: you own sealing and cooling; lowest cost, most design freedom |
VESA | Arms and brackets | Standard 75 / 100 mm hole pattern, so accessories are interchangeable |
Wall mount | Control rooms, workshop walls | Route cables behind; leave access for service |
Hanging | Above production lines | Check vibration and cable strain; add a safety cable |
Desktop stand | Test benches, labs | Adjustable tilt helps avoid glare |
Sealing is a system design
The real front IP rating depends on the cut-out size, the gasket and the panel thickness, not only on the display.
Mounting brackets and cut-out drawings provided for each project
Three Platform Options
Monitor with AD board, ARM Panel PC or x86 Panel PC
| Monitor with AD Board | ARM Panel PC | x86 Panel PC |
Inputs & I/O | HDMI / DP / VGA / DVI + USB touch | 1–2 LAN, USB, RS232 / RS485 (isolation optional), GPIO | 2 LAN, USB 3.0, RS232 / RS485, GPIO, HDMI / DP out |
Processor | Uses customer's host | Rockchip RK3568 / RK3588 | Intel Celeron J6412, Core i3 / i5 / i7 |
OS | Customer's | Android, Linux | Windows 11 IoT Enterprise LTSC, Linux |
Techtion Smart Online Webinar
Platform Options
www.techtionsmart.com
Same front, three platforms
Monitor, ARM and x86 versions can share the same front size, cut-out and mounting, so your machine front stays unchanged.
Depth, rear I/O and cooling may differ by platform.
Protection Ratings: IP and IK by Environment
Pick the rating from the site, not the other way round
Techtion Smart Online Webinar
IP and IK Ratings
www.techtionsmart.com
IP (IEC 60529): IP65 water jets · IP66 powerful jets · IP67 immersion 1 m / 30 min · IP69K hot high-pressure cleaning
IK (IEC 62262): impact energy · IK07 = 2 J · IK08 = 5 J · IK10 = 20 J (5 kg dropped from 40 cm)
Environment | Suggested rating | Why |
Dry control room, inside a cabinet | Front IP65 | Dust and the odd splash only |
CNC and machining (coolant, oil mist) | Front IP65-IP66 + oil-resistant gasket | IP is tested with clean water; coolant and oil age standard gaskets |
Outdoor, semi-outdoor | Full IP65-IP66, IK08 or higher | Rain, dust and knocks in public areas |
Food and beverage wash-down | IP66 / IP67 or IP69K, stainless housing | Daily hot, high-pressure cleaning |
Possible flooding (pits, decks) | IP67 | Temporary immersion |
Immersion (IP67) and jets (IP66 / IP69K) are separate tests: for wash-down, ask for both.
Sources: IEC 60529 and Wikipedia "IP code" (IPX7 does not imply IPX5/X6); ISO 20653 IP69K; EN 62262 impact table
Connectors and Waterproof Plugs
Every cable entry is a possible leak: pick the connector by site, signal and service
Techtion Smart Online Webinar
Connectors
www.techtionsmart.com
Connector | Typical use | Sealing | Choose it when |
Pluggable terminal block | DC power, DI / DO | None | The unit sits in a dry cabinet; easy wiring on site |
M12 A-coded | Sensors, DC power, signals | Typically IP67, mated | Factory floor, vibration, ready-made cables |
M12 D / X-coded | Ethernet, 100 Mbit / up to 10 Gbit | Typically IP67, mated | Network on the machine instead of RJ45 |
Waterproof circular (aviation type) | Power and signals in one plug | IP67 / IP68, mated | Several signals through one sealed point, custom pinout |
Waterproof USB / RJ45 | Service port, data download | Only with the cap on | A port used now and then |
Cable gland | Fixed cable through the housing | IP66–IP68 | No need to unplug; fewest leak paths |
1
Sealed only when mated
An open socket has no IP rating. Fit caps on unused or service ports.
2
Lock against vibration
Use screw or bayonet locking on machines and vehicles, not friction-fit plugs.
3
Match the material to cleaning
Wash-down needs stainless or hygienic connectors and cable glands.
Rule of thumb: use only the ports you need. Fewer connectors, fewer leak paths.
M12 coding per IEC 61076-2-101 / -109. IP ratings apply to the mated connector; actual rating depends on the series and the housing seal.
TECHTION
SMART
04
From Prototype to Long-Term Supply
EMC, I/O customization, reliability testing, EOL and BOM control.
From Prototype to Mass Production
A verified path from first sample to stable production
1
DFX Review
2
EVT / DVT / PVT
3
FAT / SAT
4
Mass Production
Reliability testing per IEC 60068: cold (-2-1), dry heat (-2-2), damp heat (-2-78), vibration (-2-6)
Techtion Smart Online Webinar
Prototype to Production
www.techtionsmart.com
Thermal and power modelling before tooling
Catches: design risks early
EVT: does it work?
DVT: is it reliable (temperature, EMC)?
PVT: can the line build it?
Factory and on-site acceptance
Catches: setup and integration issues
SN traceability (MES / SPC), burn-in before shipment
ECN for every engineering change
Catches: early-life failures
Tip for buyers
Before ordering mass production, ask for the DVT test report. The next page shows the test equipment in our lab.
DC Voltage Regulator /
Electronic Load
Withstand Voltage Test
Static Electricity Test
Aging Test
Programmable Temperature and Humidity Test
Drop Test
Vibration Test
Salt Spray Test
Programmable Rain Test
Programmable High and Low Temperature Resistance Test
IK Rating Test
UV Test
Reliability Test
EMC and Electrical Tests
The tests an industrial display is usually expected to pass
ESD
IEC 61000-4-2
Radiated RF immunity
IEC 61000-4-3
EFT / Burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Conducted RF immunity
IEC 61000-4-6
Conducted & radiated emission
Insulation & withstand voltage
Test plan set per project: tell us your target environment and standard
Techtion Smart Online Webinar
EMC Tests
www.techtionsmart.com
Industrial is not residential: IEC 61000-6-2 (industrial) vs IEC 61000-6-1 (residential)
Residential
Industrial
Radiated RF
3 V/m
10 V/m
Conducted RF
3 V
10 V
EFT on AC power
±1 kV
±2 kV
ESD
±4 / ±8 kV
same
Tip: tell your supplier the target environment (industrial or residential) at the start. It decides the test levels.
Source: IEC 61000-6-1 / 6-2 generic immunity standards. Radiated RF level shown for 80 MHz–1 GHz; ESD ±4 kV contact / ±8 kV air.
I/O and Function Customization
Choose the interface by distance, number of devices and electrical noise
Techtion Smart Online Webinar
I/O Customization
www.techtionsmart.com
| RS232 | RS485 | Ethernet (LAN) |
Connection | One to one | One bus, many devices | Network, many devices |
Distance | Short, about 15 m | Long, up to about 1200 m | About 100 m per copper cable |
Typical use | Legacy devices, service port | Modbus RTU to PLCs, meters, drives | Modbus TCP to PLCs, MES, remote access |
1
Isolate in noisy plants
Isolated RS485 ports block ground loops and spikes from drives and motors.
2
Metal housings block radio
Stainless or aluminium housings need external antennas for 4G and Wi-Fi.
3
CAN where machines move
Tractors, mobile and construction machinery use CAN (SAE J1939, ISOBUS). Factory floors mostly use RS485 and Ethernet.
Also added per project: isolated DI / DO, relay output, CAN, extra LAN or COM ports, Wi-Fi / 4G (external antenna), RFID / NFC operator login, barcode scanner, light sensor.
Typical values: TIA-232 (RS232), TIA-485 (RS485, at low data rates), IEEE 802.3 (Ethernet over twisted pair). Actual reach depends on cable and speed.
EOL and BOM Control
Four things to ask any supplier for a long-term program
Techtion Smart Online Webinar
EOL and BOM Control
www.techtionsmart.com
1
Lifecycle
How long will the model be supplied?
Why ask:
The panel and chipset usually go EOL first; consumer panels change generation fast.
2
EOL + LTB
Notice before end of life, plus a last-time-buy window
Why ask:
Gives you time to stock up or redesign.
3
PCN
Written notice before any component change
Why ask:
An "equivalent" part can still change colour, touch feel or drivers.
4
Form-fit-function
A replacement with the same size, interfaces and function
Why ask:
Housing, cut-out and software stay unchanged.
Our practice: BOM frozen before mass production, ECN for every change, PCN for changes that reach you, EOL notice in advance.
| What it is | When |
ECN (engineering change notice) | Internal record of a change: what, why, and from which batch or serial number | Every change |
PCN (product change notice) | Notice to the customer before a change ships | When form, fit, function or reliability may change |
TECHTION
SMART
05
Project and Product References
Selected industrial projects and standard product platforms.
Industrial Project References
Selected delivered projects and the selection points behind them
Techtion Smart Online Webinar
Project References
www.techtionsmart.com
Agricultural machinery, Jiangsu
7" outdoor Panel PC · sunlight, wide voltage
Smart agriculture, Beijing
13.3" outdoor monitor · rain and dust
Meat processing plant, Shenzhen
19" stainless Panel PC · wash-down
Aquatic processing
15" · wet processing area
Shipbuilding
17" stainless monitor · vibration, salt air
Medical equipment
17" medical monitor · built in, 24/7
EV charging stations, Nanjing
32" display · outdoor sunlight, impact
Product Platforms
Standard models to start a custom project from
Model | Type | Fits | Size | Brightness | Touch | Protection | Platform | Power | Working Temp. |
TS-156PCBX | Stainless Panel PC | Wash-down, food | 15.6" 1920×1080 | 1000 nits | PCAP optical bonded | IP67, IK10 | Intel J6412, 4G/8G RAM, SSD 128G/256G/512G Windows 11/Linux optional | DC12V | -20°C ~ 70°C |
TS-215PCBX | Stainless Panel PC | Wash-down, food | 21.5" 1920×1080 | ≤1000 nits | PCAP optical bonded | IP67 | Intel J6412 8+128G | DC12V | -20°C ~ 70°C |
TS-215ARBX | Stainless Panel PC | Wash-down, single app | 21.5" 1920×1080 | ≤1000 nits | Resistive | IP67 | RK3288, Android | DC12V | -20°C ~ 70°C |
TS-190MCBX | Stainless Monitor | Wash-down, existing host | 19" 1280×1024 | 1000 nits | PCAP optical bonded | IP67 | AD Board | DC12V | -20°C ~ 70°C |
TS-185MCBX | Monitor | Strong light, semi-outdoor | 18.5" 1920×1080 | 1500 nits | PCAP optical bonded | IP67 | AD Board | DC12V | -20°C ~ 70°C |
TS-215THDL | Mini LED Monitor | Strong light, high contrast | 21.5" 1920×1080 | 1500–3000 nits local dimming | No touch | Front IP65 | AD Board (HDMI in) | DC12V | -20°C ~ 70°C |
J Series Monitor | Aluminum + sheet metal | Indoor cabinet | 10.1"–21.5" | 350–500 nits (high brightness optional) | PCAP optional | Front IP65 | AD Board | DC 9–36V | -20°C ~ 70°C |
J Series Panel PC | Aluminum + sheet metal | Indoor cabinet, varying supply | 10.1"–21.5" | 350–500 nits | PCAP optical bonded | Front IP65 | x86, Windows 10/11, Linux | DC 9–36V | -20°C ~ 70°C |
Techtion Smart Online Webinar
Product Platforms
www.techtionsmart.com
TECHTION
SMART
06
Selection Checklist and Q&A
Questions to answer before choosing a display or Panel PC for your equipment.
Selection Checklist
Nine questions to answer before choosing a display or Panel PC
1
Where is it used: indoor, bright floor or outdoor?
→ brightness, bonding
2
What temperature range on site?
→ panel grade, heater
3
Gloves, wet hands or stylus?
→ touch type
4
What power does the machine have?
→ power input
5
Host PC already? Windows-only software?
→ monitor, ARM or x86
6
How is it mounted and cleaned?
→ mounting, IP rating
7
Which I/O? Industrial or residential site?
→ interfaces, EMC level
8
9
Target market and certifications? (CE, UKCA, FCC, UL…)
→ design rules, test plan, timeline
How many years must it stay in production?
→ EOL, BOM control
Send us these 9 answers and we will propose a configuration.
Techtion Smart Online Webinar
Selection Checklist
www.techtionsmart.com
Q&A Session
Contact Us
Shenzhen Techtion Smart Electronics Co., Ltd
Address: Room 902, 9th Floor, Shenzhou Tianyun Building, Bell Road, Bantian Street, Longgang District, Shenzhen, China.
Contact: Sales Team
Tel: +86 755 84827079
Mail: sales@techtionsmart.com
Website:www.techtionsmart.com
Your Reliable ECO-Friendly Display Terminal Partner
www.techtionsmart.com
Shenzhen Techtion Smart Electronics Co.,Ltd
THANKS FOR WATCHING