Guideline Update: Sterilization 2025
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
These slides are adapted from the webinar Guideline Update: Sterilization 2025 presented September 10, 2024. To listen to the webinar, visit https://www.aorn.org/education/education-for-individuals/recorded-webinars
Amber Wood is a Senior Perioperative Practice Specialist at AORN where she has served as lead author for several AORN Guidelines. Amber offers clinical information to members via the AORN Consult Line and contributes regularly to the Clinical Issues column in the AORN Journal. She has served as a member of the Association for the Advancement of Medical Instrumentation (AAMI), is a liaison to the CDC Healthcare Infection Control Practices Advisory Committee (HICPAC) and is a fellow of the Association for Professionals in Infection Control and Epidemiology (APIC).
Developed and originally presented by
Amber Wood, MSN, RN, CNOR, CIC, FAPIC
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
��������Objectives��
Outcome
Eighty percent of perioperative RN attendees will gain knowledge of evidence-based practices related to sterilization and transfer this knowledge into clinical practice.
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Surgical Site Infection (SSI)
MORTALITY
2- TO 11-FOLD INCREASE
75% DEATHS DIRECTLY ATTRIBUTED TO SSI
LENGTH OF STAY
EXTENDED 9.7 DAYS
COST
$3.3 BILLION ANNUALLY IN US
$20,000 PER ADMISSION
NHSN 2024; Berrios-Torres 2017
Purpose
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Process devices based on intended use
Sterilization provides the highest level of assurance that surgical items are free of viable microbes
Single-use
Terminal Sterilization
Liquid Chemical Sterilization
Automated HLD
Manual HLD
Margin of Safety
Rutala 2008; Rowan 2023; Rutala 2023
1.1-2
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
What’s new?
Short-cycle sterilization
Additive manufacturing
Transport vehicles
Water quality
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Manufacturer’s Instructions for Use (IFU)
Device
Packaging
Sterilizer
ANSI/AAMI ST79; ANSI/AAMI ST8; FDA 2015
1.4
Written Clarification
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Ophthalmic Instruments
Toxic Anterior Segment Syndrome (TASS)
Unless validated for ocular toxicity, avoid low-temperature sterilization methods
Park 2018; Chang 2018
1.4.5
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Ophthalmic Instrument Cleaning and Sterilization Task Force
Chang 2018; Chang 2018
5.5
Practice
Short-cycle sterilization
Study
Sterilization effective regardless of interruption of the full drying time
Position
When used in accordance with the IFU of FDA-cleared sterilizers, short-cycle sterilization is appropriate for routine use between sequential same-day ophthalmic cases
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Short-Cycle Sterilization
Centers for Medicare and Medicaid Services (CMS) 2014; Chang 2018
5.5
Glossary
A sterilization method for a wrapped or contained load that is sterilized in accordance with the device, sterilizer, and packaging manufacturer’s instructions for use; includes a dry time; and is packaged in a sterile barrier that permits storage for use at a later time. – AORN
Correct use of a sterilization cycle for a wrapped/contained load that meets the device manufacturer’s IFU is the equivalent of terminal sterilization and is not IUSS if it includes a dry time and is packaged in a wrap or rigid sterilization container intended to be stored for later use. – CMS
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Table 1. Differences Between Terminal, Immediate Use, and Short-Cycle Sterilization | Terminal | Short-Cycle | IUSS |
Packaging | Wrapped or contained for storage | Contained for IUSS | |
Exposure time | Full | ||
Dry time* | Full | Shortened |
0-1 minute
|
Moisture is expected and accepted inside the package | No | Yes | |
The item is suitable for storage after the cycle | Yes | No | |
* Full dry time means the entire dry time recommended in the device manufacturer’s IFU. When a shortened dry time is not provided in the manufacturer’s IFU, the organization is responsible for verifying that a shortened dry time is capable of producing a dry package. | |||
5.5
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
NEW AORN Recommendation
5.5
Perform short-cycle sterilization only when all of the following conditions are met:
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
AORN Recommendation: IUSS
5.4
Perform IUSS only when all of the following conditions are met:
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
NEW IUSS Study
Tantillo 2022
5.4
Propensity score-matched cohort study
70,600 patients
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
IUSS Study Results
Tantillo 2022
5.4
More infections in the IUSS group
Before matching
No statistically significant difference
After matching
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
IUSS Study Conclusions
Tantillo 2022
5.4
IUSS is safe to perform in orthopedic procedures when personnel adhere to the manufacturer’s IFU and guidelines for IUSS from AORN and AAMI.
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Cooling Instruments after IUSS
Roper 2018
5.3.4
Prevent thermal injury
Instrument use
Cooling time
Most efficient method
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Additive Manufacturing
3D Printing
FDA 2017
1.6
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Sterilization Method
FDA 2017
1.6
Material
Polymer
Metal
Printing Pattern
Porous
Voids
Tortuous
Chemical Reaction
Residue
Device integrity and performance
Penetration of the sterilant
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Patient-Matched Devices
FDA 2017
1.6.3
Glossary
Based on patient-specific measurements or imaging
Establish process for determining shelf life
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Sterilization of 3D Printed Devices
FDA 2017; Nack 2020
1.6
Manufacturer
End User
On-Site Manufacturing
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Sterile Processing Area Design
2.3
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Transport Between Facilities
Standardization and oversight
Transport vehicles
Compliance with regulatory requirements
3.3
Glossary
ANSI/AAMI ST79; Cardone 2020; US Department of Transportation 2022
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Water Quality
ANSI/AAMI ST108
10.16
12.8
Critical for effective sterilization
Monitor and control the quality of the water supply system that supplies steam generators (boilers)
Emergency water supply plan
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Wet Packs
ANSI/AAMI ST79; van Doornmalen 2019; Barbosa Rodrigues 2022
Can indicate a problem
Investigate & take corrective action
New publications
5.7
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Sterilization Monitoring
Physical Monitors
Chemical Indicators
Biological Indicators
ANSI/AAMI ST79
10.3-7
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Routine Efficacy Testing
Sterilization Method | Frequency | Recommendation |
Steam sterilizers | Weekly, preferably each day the sterilizer is used | 10.7.1 |
Low-temperature hydrogen peroxide sterilizers | Each day the sterilizer is used, preferably with every load | 10.10.2 |
Peracetic acid sterilant systems | Each day the sterilizer is used | 10.11.2 |
Ethylene oxide sterilizer | Every load | 10.9.2 |
Dry-heat sterilizers | Weekly, preferably each day the sterilizer is used | 10.12.2 |
Table 3
ANSI/AAMI ST79; ST41; ST58; Rutala 2008
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Single-Use Devices
FDA requirements for reprocessing single-use devices
Patient education
FDA 2018; Grantcharov 2019
1.5
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Guideline Essentials
https://www.aorn.org/essentials
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
Questions?
FAQs
AORN Nurse Consult Line
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
References
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.
References
Copyright © 2024 AORN, Inc. All rights reserved. Used or adapted with permission.