Don Mears
Oil & Gas Industry Consultant
NACE San Antonio, Texas
March 16, 2010 TEG 119X Meeting
Handheld X-ray Fluorescence for PMI &
Residual Elements in HF Alkylation Units
Presenter – Don Mears
2
Agenda
Special Thanks to the Borger, Texas Refinery
3
Thermo Fisher Scientific – An Important Mission
The world leader in serving science
Enabling our customers to make the world…
Healthier
Cleaner
Safer
4
Unmatched Global Capabilities
Serving science in new and compelling ways
Leading provider of analytical instruments, equipment, reagents and consumables, software and services for research, analysis, discovery and diagnostics.
5
Thermo Fisher Scientific: Refining Solutions
SOLA FLARE
SOLA II
Blending
SOLA II
FCC Fractionator
SOLA II TRACE
SOLA II TRACE
SOLA II TRACE
SOLA II
Blending
SOLA II Lab
SOLA II
Blending
Tracker XP
Tracker XP
Flo-Cal 6000
Flo-Cal 6000
Flo-Cal 6000
Flo-Cal 6000
Flo-Cal 6000
Flo-Cal 6000
Flo-Cal 6000
Flo-Cal 6000
Flo-Cal 6000
Flo-Cal 6000
Sentinel PRO
Sentinel PRO
Sentinel PRO
Prima PRO
M-PULSe
M-PULSe
M-PULSe
Kril PRO
LevelPro
DensityPro
LevelPro
DensityPro
GC-ICP-MS, TS, XRF, ICP
XRF
XRF, ICP
XRF
GC
XRF
GC
GC
XRF
XRF, ICP
GC-ICP-MS, TS, XRF, ICP
LIMS
TVA1000B
GC-ICP-MS, TS, XRF, ICP
A Wide Range of Proven Products and Service Offerings to Help You Improve Product Quality, Process Efficiency, Safety and Environmental Monitoring.
6
Our Refining Products and Service Offerings
7
And What They Can Do For You…
8
Brief History of Portable XRF
First generation alloy analyzer, the TN 9200, 1960s
9
Evolution
10
How XRF Works
11
Handheld Thermo Scientific Niton XRF analyzer being used to inspect piping system
Latest Developments in Handheld XRF: GOLDD Technology
12
Thermo Scientific Niton XRF Analyzers - Product Lineup
Niton® XL2
Value Leader
Niton XL3 GOLDD™
Performance Leader
Niton XL3
Feature Leader
13
New GOLDD Technology
14
X-Ray Tube and New Light Element Analysis in Air
15
Complete System Optimization
16
GOLDD: Quantum Advancements with XL3 Analyzers
Significantly lower LOD’s for critical elements
17
3-Sigma LODs: Ti, Fe, and Cu Alloys; All Units %wt
TIME | 60s per filter | 60s per filter | 60s per filter |
Element | Ti Base Wt. % | Fe Base Wt. % | Cu Base Wt. % |
Sb | 0.005 | 0.006 | 0.008 |
Sn | 0.005 | 0.008 | 0.015 |
Pd | 0.005 | 0.006 | 0.010 |
Mo | 0.002 | 0.002 | 0.002 |
Nb | 0.002 | 0.002 | 0.003 |
Zr | 0.002 | 0.002 | 0.003 |
Bi | 0.002 | 0.002 | 0.003 |
Pb | 0.002 | 0.009 | 0.003 |
Se | 0.002 | 0.002 | 0.002 |
W | 0.015 | 0.015 | 0.015 |
Zn | 0.005 | 0.005 | 0.030 |
Cu | 0.008 | 0.009 | N/A |
Ni | 0.012 | 0.020 | 0.011 |
Co | 0.008 | 0.080 | 0.005 |
Fe | 0.015 | NA | 0.007 |
Mn | 0.017 | 0.020 | 0.007 |
Cr | 0.015 | 0.003 | 0.005 |
V | 0.060 | 0.003 | 0.003 |
Ti | N/A | 0.003 | 0.003 |
P | 0.025 | 0.030 | 0.040 |
S Si | N/A 0.070 | 0.050 0.075 | 0.060 0.080 |
Al | 0.375 | 0.500 | 0.700 |
18
Thermo Scientific Niton XRF Analyzers in Downstream Process
Handheld XRF Analyzers
19
Handheld XRF PMI Applications
20
Refining Piping Systems Failure: The Challenge
Source: Marsh and McLennen (property protection and risk consultants)
21
Guidelines and Application Procedures for API-RP 578 Using XRF and OES Technologies� �
In response to increasing industry safety demands, Analytical Training Consultants has produced the API Certification PMI Training Course
22
Introduction
In today's risk-based QC environment, the need for positive material identification (PMI) has grown dramatically in refinery and petrochemical plant operations, requiring 100% alloy material verification for designated critical components.
23
Inspection Program for HF ALKY Field Tests-API RP-571�
24
Inspection Program for HF ALKY All Refineries-API RP-571
25
Inspection Program for HF Alky Units – All Refineries�
Priority for API RP 578 2nd Edition
C> 0.18 wt%
And
Cu + Ni + Cr < 0.20 wt %
Cu | Ni | Cr | RE Sum |
0.050 | 0.078 | 0.084 | 0.212 |
26
PMI Testing of CS Pipe Interactive-”Live Demonstration”
27
Conoco Phillips Crude Unit Test Shot Results Low Si as Discussed in API RP-939C
28
Inspection Program for Low Si – All Refineries �
Priority for API RP 578 2nd Edition
29
High Temperature Sulfidic Corrosion - API RP 939-C
Low Si-33%,PMI-18%,Specification Break-17%
30
High Temperature Sulfidic Corrosion-API RP-939-C�Field Test
5cr 0.04” Thin
31
High Temperature Sulfidic Corrosion-API RP-939-C�& HF RE Levels High in Warehouse Test
ConocoPhillips Borger, Texas Jim-SN-36965 Shots on 8-26-09 | |||||||||||
Index | Time | Duration | Line | Component | Pipe | Alloy1 | Cr | Cu | Ni | Sum | Si |
37 | 8/26/2009 16:48 | 9.64 | A17F | Elbow | 8" | Fe/CS : 0.00 | 0.03 | 0.05 | < LOD | 0.08 |
|
38 | 8/26/2009 16:49 | 40.2 | A17F | Elbow | 8" | Iron/CS : 0.22 | 0.03 | 0.06 | < LOD | 0.09 | 0.24 |
39 | 8/26/2009 16:52 | 22.51 | A17F | Elbow | 8" | No Match : *4.06 | 0.05 | 0.16 | < LOD | 0.21 | 0.59 |
40 | 8/26/2009 16:59 | 40.9 | A17F | Flange | 8" | Iron/CS : 0.24 | 0.06 | 0.04 | < LOD | 0.1 | 0.22 |
41 | 8/26/2009 17:04 | 21.15 | A17E | Elbow | 2" | No Match : *4.12 | 0.06 | < LOD | < LOD | 0.06 | 2.37 |
42 | 8/26/2009 17:05 | 23.63 | A17E | Elbow | 2" | Iron/CS : 0.24 | 0.04 | < LOD | < LOD | 0.04 | 0.39 |
43 | 8/26/2009 17:10 | 14.4 | A17G | O-let | 3/4" | No Match : *4.27 | 0.17 | 0.11 | < LOD | 0.28 | 1.38 |
44 | 8/26/2009 17:11 | 26.92 | A17G | O-let | 3/4" | TS-O6 : *3.99 | 0.17 | 0.13 | < LOD | 0.3 | 1.31 |
45 | 8/26/2009 17:13 | 29.06 | A17G | O-let | 3/4" | No Match : *4.07 | 0.17 | 0.13 | < LOD | 0.3 | 0.25 |
46 | 8/26/2009 17:20 | 29.18 | A17G | O-let | 3/4" | No Match : *5.22 | 0.05 | 0.1 | 0.09 | 0.24 | 0.82 |
47 | 8/26/2009 17:21 | 15.97 | A17G | O-let | 3/4" | Iron/CS : 0.30 | 0.04 | 0.09 | < LOD | 0.13 | 0.37 |
48 | 8/26/2009 17:27 | 60 | A02F | Flange | 4" | Iron/CS : *2.66 | 0.17 | 0.06 | < LOD | 0.23 | 0.09 |
49 | 8/26/2009 17:30 | 40.08 | A02F | Flange | 8" | Iron/CS : 1.42 | 0.11 | 0.24 | < LOD | 0.35 | 0.18 |
50 | 8/26/2009 17:33 | 36.8 | A02F | Elbow | 6 | Iron/CS : 0.21 | 0.05 | < LOD | < LOD | 0.05 | 0.23 |
51 | 8/26/2009 17:38 | 28.44 | A02F | Elbow | 6 | Iron/CS : *2.30 | 0.19 | 0.06 | < LOD | 0.25 | 0.16 |
Flange with Low Si-0.09 %
32
Summary of Don’s Test Shots- HF-RE’s
Both in Warehouse and Field Shots: 10 out of 33 Test Shots:
33%
RE’s Higher than 0.20%
33
Summery of Jim’s Test Shots in Both HF-RE’s & Crude Unit Low Si
34
Field Test with Six Samples Compared to Material Certifications from Independent Laboratory
35
Thermo Scientific Niton XRF Analyzer PMI Solutions
Extension
Pole
Hotfoot
PMI-15 Certest
Button Reader
Buttons
Wireless
Printer
Wireless
Bar Code
Reader
GPS
CMB Manual
Button
mounted
on plate
36
Field Use for Hot Pipes and Difficult Access
Extension Pole /Tri-Pod
Niton XL3 without heat shield: 599 F/315o C
Niton XL3 with heat shield : 842 F/450o C
37
PMI of Welds and Small Spot: WeldSpot™ and CamShot ™
X-RAY
DET
WeldSpot signal reduced to 3mm dia
SA`MPLE
DET
X-RAY
Standard collimation 8 mm dia
SAMPLE
38
Niton Data Transfer (NDT©) Software
39
Summary and Conclusions
40
Oil & Gas PMI Market Overview
Asset Recovery
Asset Management
41
Questions
Analytical Training Consultants, (ATC)
1719 Burning Tree
Kingwood, Texas 77339
Cell Phone: 281-684-8881
ATC Office: 281-358-1177
Fax: 281-358-2177
42