Submitted By:-�Harshita Singh Jadaun�Prashant Sarkar�Piyush Kant Arya��Under the supervision of �Mr. Ritesh Kumar Rai�(Associate Professor)

3 of 19

Table Of Content

  • Introduction
  • Working
  • Block diagram
  • Hardware Required
    1. Power supply block
    2. Microcontroller (8051)
    3. LCD
    4. Matrix Keypad
    5. Relay
    6. GSM module
    7. M8870 dual tone
    8. EEPROM
    9. 4013B d flip flop
  • Advantages
  • Future scope
  • Application
  • Conclusion

4 of 19

INTRODUCTION

  • The project aims at controlling various loads spread over a large area remotely by using DTMF concept. The DTMF command tone thus received from the phone causes electrical load switching. The project is useful for managing industrial, domestic or agricultural loads that extend over a large area.
  • The project works on the principle of DTMF tone command so received from any phone to remotely switch any electrical load.
  • The project requires a DTMF decoder interfaced to audio output socket of the cell phone. Whenever a button on the keypad is pressed the frequency thus generated from it is received by the decoder and it converts the frequency into its equivalent digital code. A microcontroller of 8051 family is used which is interfaced to relays through relay driver IC. The digital code is then provided to microcontroller that identifies the phone commands and initiates the relays to actuate the respective loads by turning them on and off.

5 of 19

WORKING

Now let’s see how the project works. First, when the power is turned on, the LCD displays a welcome screen and then asks you to enter the password to unlock it. In our case, the password is fixed i.e. 1234. By using the Keypad, the password is input and as we type it the password is seen on the LCD. If the wrong password is entered, it will display a wrong password message and ask you to enter it again. When the correct password is entered, the main screen of the circuit breaker is opened. Now the status of the 1 loads connected to the microcontroller is shown on the LCD as N for on and F for off. By the help of the keypad, when you press the desired button, the output goes to port A and turns on the relay driver IC which in turn switches the magnetic relay and thus the load turns on. By pressing the same button again, the load can be turned off. GSM modem is an important factor in proposed work The ‘AT’ commands which are received by the microcontroller through level shifted IC Max232. As per the program, an acknowledgment is received by SMS being sent depending on status and acknowledgment sent and received. The LCD screen is used to here for displaying complete operation.

6 of 19

BLOCK DIAGRAM

Microprocessor 8870 dual tone multiple frequency

7 of 19

Hardware Requirement

  • Power Supply Block
  • Microcontroller (8051)
  • LCD
  • Matrix Keypad
  • Relay
  • Relay Driver
  • LED
  • Diode(1N4007)
  • Capacitors
  • Resistors
  • GSM module
  • EEPROM
  • M8870 dual tone
  • HEF4013B d flip flop

8 of 19

1) Microcontroller(8051)

  • Microcontroller is a small computer on a single integrated circuit. A microcontroller contain one or more CPUs along with the memory and programmable input/output peripherals.
  • Microcontrollers are used in automatically controlled products and devices, such as automobile engine control systems, remote controls, office machines, applications, power tools, toys and another embedded systems.
  • In this project 8-bit microcontroller is used i.e., 8051 microcontroller.

9 of 19

2) LCD (liquid crystal display)

  • Most common LCD connected to the microcontrollers are 16 × 2 and 20  ×2 displays, this means 16 characters per line by 2 lines and 20 lines per line by 2 respectively.
  • The standard is referred to as HD44780U, which refers to the controller chip which receives data from external source and communicates directly with the LCD.

10 of 19

3) MATRIX KEYPAD

  • A keypad is a set of buttons arranged which usually bear digits , symbols, alphabets.
  • In order to detect which key is pressed in the matrix the row lines are to be made one by one and read the column.

11 of 19

4) RELAY

  • The relay is an electromagnetic switch, used to control the electrical devices. Copper core magnetic flux plays the main role here.
  • The relay’s switch connections are usually labeled COM, NC, and NO:
  • COM = Common, always connect to this; it is the moving part of the switch.
  • NC = Normally Closed, COM is connected to this when the relay coil is off.
  • NO = Normally Open, COM is connected to this when the relay coil is on

12 of 19

5) GSM module

  • The GSM modem helps to send the generated OTP. OTP generation is the main part of this project. This is done by the microcontroller. The RISC-based microcontroller consists of four ports. In which port A is dedicated for ADC. The microcontroller used for the implementation of this system is ATmega32. It is an 8-bit microcontroller with 32KB on-chip programmable flash memory. Based on the program stored in the microcontroller it shells generate the OTP. And if the passwords are matched or not, It will switch a relay also.

13 of 19

6). M-8870 dual tone

The  M-8870  is  a  full  DTMF  Receiver  that  integrates  both

bandsplit filter and decoder functions into a single 18-pin DIP

or SOIC package. Manufactured using CMOS process tech-

nology, the M-8870 offers low power consumption (35 mW max)

and precise data handling. Its filter section uses switched ca-

pacitor technology for both the high and low group filters and

for dial tone rejection.

The M-8870 decoder uses a digital counting technique to deter-

mine the frequencies of the limited tones and to verify that they

correspond to standard DTMF frequencies.

14 of 19

7) EEPROM

  • Electronically Erasable Read Only Memory plays a major part in this project. It is a non-volatile memory which is often used to store small data for immediate uses and which must be saved when the power turns off. The EEPROM store the password in our project which can be both read and overwritten when a new password is added.

15 of 19

8) 4013B dual d flip flop

The HEF4013B is a dual D-type flip-flop that features independent set-direct input (SD),

clear-direct input (CD), clock input (CP) and outputs (Q, Q). Data is accepted when CP is

LOW and is transferred to the output on the positive-going edge of the clock. The active

HIGH asynchronous CD and SD inputs are independent and override the D or CP inputs.

The outputs are buffered for best system performance. The clock input’s Schmitt-trigger

action makes the circuit highly tolerant of slower clock rise and fall times.

It operates over a recommended VDD power supply range of 3 V to 15 V referenced to VSS

(usually ground). Unused inputs must be connected to VDD, VSS, or another input.

16 of 19

ADVANTAGES :

  • Avoid electrical accident to line man
  • It is effective in providing safety to working staff.
  • It can be easily installed.
  • Uses commonly available components.

​

17 of 19

FUTURE SCOPE

  • Supervisory control and data acquisition (SCADA) is a control system so SCADA can also be implemented to know where the fault occurs in the system directly and so a lineman can directly locate the fault location and can rectify it. We can also use EEPROMS than can be interfaced to the system so the circuit breaker can, not only operate from the substation, but also from distance through wireless communication. The project can be interfaced with the GSM modem for the remote control of circuit breaker via SMS

18 of 19

APPLICATIONS :

  • Used in electrical substations to ensure line man safety
  • This system is used in buildings and Houses
  • Used in hotels and shopping malls to save the power
  • Can also be used as password based electrical appliance control or password based load control system

19 of 19

CONCLUSION :

​

  • Password based circuit breaker control to ensure the electrical line mans safety the pic microcontroller.
  • This proposad system provides a solution, which can ensure the safety of the maintenance.
  • The control to turn on/off the line with the line man only.