QUALITY CONTROL TEST FOR CONTAINERS
PACKING MATERIALS
• Any material that is used for packaging of products for their distribution and sale is said to be the packing material.
• Two types of packing material:
QUALITY CONTROL TESTS FOR GLASS CONTAINERS
�
Arsenic test: This test is for glass containers intended for aqueous parenterals. The inner and outer surface of container is washed with fresh distilled water for 5 min. ↓ Then similar steps are followed as performed in the hydrolytic test, previously described, till obtaining the final combined solution. ↓ 10ml from the final combined volume is pipetted out and to it 10 ml of HNO3 is added and dried in an oven at 130°C. ↓ 10ml of hydrogen molybdate is added and refluxed for 25 mins. ↓ It is cooled and absorbance is measured at 840nm. ↓ The absorbance of the test solution should be less than the absorbance obtained using 0.1ml of arsenic standard solution (10ppm).
QUALITY CONTROL TESTS FOR PLASTIC CONTAINERS FOR NON-PARENTERAL PREPARATIONS
1. Leakage test: 10 containers are filled with water and fitted with intended closures. ↓ They are kept inverted at room temperature for 24 hours. ↓ The test is said to be passed if there is no sign of leakage from any container. 2. Collapsibility test: • This test is applicable to containers which are to be squeezed in order to remove the contents. • A container by collapsing inward during use, yield at least 90% of its normal contents at the required rate of flow at ambient temperature.
Clarity of aqueous extract: A suitable container is taken at random, and unlabeled, unmarked and non- laminated portions is selected. ↓ These portions are cut into strips, none of which has a total surface area of 20cm2. ↓ The strips are washed free from extraneous matter by shaking them with at least two separate portions of distilled water for about 30 secs. ↓ The processed sample is taken in to the flask, previously cleaned with chromic acid and rinsed with distilled water. ↓ 250ml of distilled water is added to the flask, covered and autoclaved at 121°C for 30 mins. ↓ The extract is cooled and examined. It should be colorless and free from turbidity.
QUALITY CONTROL TESTS FOR CLOSURES Preparation of sample: • The closures are washed in 0.2% w/v of anionic surface active agents for 5 mins. • Rinsed five times with distilled water and 200ml water is added. • Subjected to autoclave at 119°C to 123°C for 20-30 mins covering with aluminum foil. • Cooled and solution is separated from closures (Solution A). 1. Residue on evaporation: • 50ml of Solution A is evaporated to dryness on a water bath and dried at 105°C. • The residue weighs not more than 4 mg.
Sterilisation test: The closures used for the preparation of the sample solution shall not soften or become tacky and there shall be no visual change in the closure. 3. pH of aqueous extract: To 20ml of solution A, 0.1ml of bromothymol blue solution is added. ↓ NMT 0.3ml of 0.01M NaOH or 0.8ml of 0.01M HCl is rqd. to change the color of the solution to blue or yellow respt.
QUALITY CONTROL TESTS FOR PAPER AND BOARD Test conditions: Temperature- 23 ± 1°C ; Relative humidity- 50±2%
REFERENCES:
• C, Rambabu, V, Ananth, R. T, Srikanth, S. K, Dona, K. G, Arun, T, Tinu, Manavalan, B. M, Venkanna, S. H, Viswa, J. K, Ghaharin. A Concise Textbook of QC & QA. KMCH College of Pharmacy, Coimbatore. 2011. 179-189. • Government of India, Ministry of Health. Indian Pharmacopoeia Volume I. The Indian Pharmacopoeia Commission, Ghaziabad. 2010. 683-692.