1 of 25

SpaceLogic RP-V Advanced

Part of EcoStruxureTM Connected Room Solutions

Value Proposition Presentation

© 2022 Schneider Electric. All Rights Reserved.

2 of 25

© 2021 Schneider Electric, All Rights Reserved | Page 2

Source: Global Building Stock Database 2Q20

The world of your building

The total building stock is estimated to grow to

124.7 billion m2

in 2029 from 102.9 billion m2.

3 of 25

Source:

1 Architecture 2030, 2020

2 Facts + Statistics: Global catastrophes, Insurance Information Institute, 2020

3 U.S. Environmental Protection Agency, 2020

4 Joseph G. Allen, Healthy Buildings Program, Harvard University, 2019

>350

natural + man-made �disasters in the world�in 20192

>30%

of the energy is�wasted in buildings3

~40%

of the world’s�CO2 emission comes�from buildings1

~90%

of our time�is spent indoors4

The world of your building

4 of 25

Hyper-efficient

Maximize performance by optimizing system and workflow

Resilient

Robustly withstand internal and external challenges

Sustainable

Consume less, extend life of assets, and spend wisely

People-centric

Ensure comfortable, productive setting for all people

The Foundation of Buildings of the Future

5 of 25

  • Optimize energy footprint of the building

  • Only heat and cool rooms when they’re being used

Hyper-efficient

Maximize performance by optimizing system and workflow

  • Future ready with insights and analytics to enable rezoning and right sizing

  • Ensure optimal IAQ, energy use and comfort at the room and zone level

Resilient

Robustly withstand internal and external challenges

  • Reduce energy use and carbon intensity for heating/cooling and lighting

  • Enable well-being standards, like WELL, LEED, BREEAM

Sustainable

Consume less, extend life of assets, and spend wisely

  • Drive enhanced occupant comfort, well being

  • Enables people focused use cases like circadian lighting and occupant-based ventilation

People-centric

Ensure comfortable, productive setting for all people

SpaceLogicTM RP-V Advanced enables our vision for Buildings of the Future

6 of 25

Features and Capabilities

  • On board Air Flow Sensor
    • range of 0-249Pa
    • resolution of 0.017Pa
    • enabling close control at low air flow
  • Built in Damper Actuator
    • 10Nm torque
    • Acceptable spindle size of 9.5 or 12.7mm
    • enables connection and control of all standard VAV boxes
    • Bluetooth (BLE), use with: 
      • EcoStruxure Engage App
      • Building Commission App
  • Two Configurable RS485 port
    • Connection to local intelligent devices either via Sensor Bus, Room Bus or Modbus RTU.  
    • Configurable to BACnet MS/TP when hosted under a server using  RS-485 adapter.

Confidential Property of Schneider Electric |

Page 6

Name

Universal Input/Output

SSR Outputs

Air Flow Sensor

RP-V-4A

4

1

RP-V-5A

2

3

1

7 of 25

Occupancy & CO2 Control of Variable Air Volume (VAV)

Results

Measuring occupancy levels results in a quicker response to change �than waiting for a rise in CO2, providing the best possible ventilation rates.

As the room empties and CO2 levels fall, VAV will modulate to minimum flow.

The AHU continuously tracks demand from all the system VAV boxes modulating fan speeds to maintain pressure levels in the supply and extract ducts.

2

1

AHU provides pre treated air to VAV box and the damper varies air flow to room diffuser.

VAV damper is controlled direct via the built in actuator in the RP-V Advanced. �Wired communication to Automation Server.

4

5

6

7

Wall sensor provides temp & CO2 data to RP-V.

Using data from sensors �and room occupancy design, VAV setpoint is scheduled between min-max flow.

As CO2 levels change, VAV box setpoint is rescheduled to meet the maximum CO2 requirements.

Ceiling mounted Multi Sensor or Insight-Sensor, provides occupancy count data

3

VAV modulates air volume in room, achieving desired setpoint

8 of 25

SpaceLogic RP-V Advanced is the IoT hub that enables demand control ventilation to create the Room of the Future

  • New air flow sensors that can measure very low differential pressures with high resolution, <0.02Pa
  • Extended torque rates (from 6Nm to 10Nm) to handle larger duct dampers
  • Two controller versions with different I/O mixes to fit different applications
  • Pre-defined HVAC applications for RP-V saves time during engineering and commissioning
  • Built-in actuator and onboard I/O for easy and efficient installation and commissioning

Did you know: Demand control ventilation practices driven by sensor data save 10-20% of building HVAC energy use1

1 Azizi, Olofsson, Nair; Demand-controlled energy systems in commercial and institutional buildings: a review of methods and potentials; Umea University, Sweden

9 of 25

Which do I choose?

Confidential Property of Schneider Electric |

Page 9

I’m looking for an entry-level model for a basic HVAC application

My building will only have BACnet MS/TP and I don’t plan to upgrade to IP

I need very basic variable air volume (VAV) HVAC control

EasyLogic

RP-V

SpaceLogic

RP-V Advanced

SpaceLogic

MP-V Pro

My project requires a room bus for Connect Room Solution,

and/or I plan to have connected lights, blinds, and Living Space sensors

My application requires the use of 2 RS-485 ports at the same time

My building uses ethernet / BACnet IP for communication

I need high load (1.5A) or DC capability on the DO

I need more I/O resources and expanded memory for a larger project and/or more advanced application

I need a premium CPU to host complex integrations

10 of 25

RP-V Advanced – Part of the SpaceLogic Range

Confidential Property of Schneider Electric |

Page 10

11 of 25

Confidential Property of Schneider Electric |

Page 11

  • Controller at the room level that creates a truly connected room
  • Enables variable air volume (VAV) ventilation schemes for air circulation
  • Integrated light, blinds, temperature control, and room sensors
  • Ability to integrate with occupant apps and workplace management software

EcoStruxureTM Connected Room Solutions creating the Room of the Future – now with RP-V Advanced

12 of 25

Confidential Property of Schneider Electric |

Page 12

Internal Communication - Ceiling

EcoStruxure

Building Commission

Mobile App

Internal Communication - Wall

RP-V Advanced

Room 1

Lighting

Blind

1-10v

Insight-Sensor

SMI

Physical IO

Room 2

1 x AS-P per floor

Room 3

1 x Enterprise Server per building

BACnet IP

BACnet IP

IP Backbone

Floor 1

Floor 2

1 x AS-P per floor

EcoStruxure Building Engage

Internal Communication - Ceiling

Internal Communication - Wall

RP-V Advanced

Lighting

Blind

1-10v

Insight-Sensor

SMI

Physical IO

Living

Space

Sensor

Remote �Control

EcoStruxureTM Connected Room Solutions with SpaceLogic RP-V Advanced: Architectural Diagram

13 of 25

SpaceLogic RP-V Advanced creates comfortable, productive Rooms of the Future using in a hyper-efficient and streamlined approach

Confidential Property of Schneider Electric |

Page 13

Seamless Integration

Out of the box integration with BMS eliminates 3rd parties and heavy engineering

Meet Tenant Demands

Achieve the right balance of wellbeing, comfort, and sustainability

Demand control ventilation for fresh air at the room level

Room-Level Control

Connected Room Solutions

A complete, modern, modular room solution from one innovative supplier

14 of 25

SpaceLogic RP-V Advanced creates comfortable, productive Rooms of the Future using in a hyper-efficient and streamlined approach

Confidential Property of Schneider Electric |

Page 14

Today: Floor Level Integration

    • Complex installation, service and maintenance
    • Double effort in projects, installations and commissioning
    • Units with over bridging functionality, different vendors
    • Complex construction planning
    • Different user interfaces
    • Several sources of errors

Future: Room Level Integration

    • Simpler planning of projects
    • Faster procurement, fewer partners
    • More effective commissioning, seemless integration
    • Streamlined usability
    • Flexible rezoning when changes
    • Available IoT-data; data ownership

15 of 25

Confidential Property of Schneider Electric |

Page 15

Building Owner value: balance comfort with efficiency

Create demand-driven ventilation, reducing HVAC energy use when not actually needed

Modernize and meet future of digital smart buildings with minimal disruption

Achieve well-being and energy standards, like WELL, LEED and WiredScore more easily

Benefit from higher operational and energy efficiencies for increased building value and ROI

Integrate with lighting, blinds, and other devices to achieve sustainability and wellness

16 of 25

Confidential Property of Schneider Electric |

Page 16

Consultant Specifier value: high-end solution meets the needs of both owners and occupants

Provide a variable air volume (VAV) ventilation scheme for fresh air circulation

Create a flexible, future-proof design approach for long lasting building value

Achieve value-add energy and well-being standards such as WELL, LEED and WiredScore

Automatically reduce energy consumption with integration of electrical, lights, blinds, and HVAC

Offer an open, secure, scalable solution in a single architecture to win more work

17 of 25

Confidential Property of Schneider Electric |

Page 17

System Integrator value: seamless install, more opportunity

Provide a modern VAV solution that saves cost with quick install, integration, & commissioning

Grow profitability by winning more business with a highly differentiated solution

Increase project opportunities by offering an increased scope for Connected Room Solutions

Expand scopes with value-added features, rezoning flexibility, easy ladder-free upgrades

18 of 25

Use Case: Air quality as the control point

Confidential Property of Schneider Electric |

Page 18

.

Why ventilate when it´s not needed? The RP-V Advanced controller measures the air quality and adjust the air flow to create a healthy climate in balance with the demand.

Controlling the air volume depending on the occupancy level in the room is an approved method on the market and lets the AHU operate optimally and energy smart. The AHU doesn’t need to produce more treated air than required by the system.

Fits perfectly in conference rooms and office spaces that have variations in the number of people occupying the area.

19 of 25

Use Case: Flexible and Modular Workplace

Confidential Property of Schneider Electric |

Page 19

.

Mobile cubicle walls gives the user the possibility to change and customize the meeting space on-the-fly, but it also puts great demands on the HVAC system which is often designed for a static setup of the rooms

SpaceLogic RP-V Advanced can be a part of EcoStruxure Building Operation which supports the dynamic setup of the rooms.

As an example, a digital input from a folding wall can trigger a function that includes several RP-Vs to work as one room controller, minimizing the risk of counteracting against each other causing unwanted energy usage.

20 of 25

Use Case: Connected room with RP-V Advanced

Confidential Property of Schneider Electric |

Page 20

.

Integration of HVAC, light and blinds as separate systems doubles installation and commissioning efforts. Units with over-bridging functionality from different vendors involve complex planning, multiple user interfaces and potential sources of error. Using ONE system with EcoStruxure Building Operation and SpaceLogic overcomes these problems.

Occupants’ cognitive abilities, health, productivity and well-being, are directly impacted by decisions in engineering, operations and the running of buildings. EcoStruxure Building Operation with Connected Room Solutions, does not only offer demand driven VAV zones, but also integration of light, blind and noise level. All pieces together, will allow for optimal occupant comfort and a well-being experience.

In addition to above, the available building IoT data and ownership of this, will also become clearer when integrating into ONE system.

EcoStruxure Building Operation connecting to the Edge level down to zone level, allows the building owner to change layout and re-zoning when changes.

21 of 25

Use Case: Quick installation with RP-V Advanced

Confidential Property of Schneider Electric |

Page 21

.

Avoid starting the design work from scratch and download quality-proven standard VAV applications that comply with ASHRAE 36 standard.

The built-in isolated power supply will minimize the self power consumption which could be a significant factor when creating energy-optimized spaces. It also allows the installer to use a centralized transformer solution instead of wiring one to each unit.

SpaceLogic RP-V Advanced acts as the IoT hub in the room space areas, both wired and wireless. Perform fast retrofit and replace the old room unit with a new wireless unit and avoid time-consuming re-wiring.

Start commissioning before the network cable infrastructure is in place by using the EcoStruxure Building Commission app. Perform checkout, configure set-points and save reports.

22 of 25

Use Case: Service your system

Confidential Property of Schneider Electric |

Page 22

.

Tools to make migration easy. Quickly configure, customize and duplicate applications.

SpaceLogic RP-V Advanced supports both BACnet IP and MS/TP enabling easy integration on existing infrastructure to minimize cost.

Mechanically compatible with B3, MNB, MNL and TAC 102 range of VAV controllers making exchange easy and strait forward.

Support for Zigbee enables replacement of existing room units to Zigbee based room units, without re-wiring.

23 of 25

Use Case: Modernize your system

Confidential Property of Schneider Electric |

Page 23

.

Improve space utilization - the ‘new normal’ is a hybrid workplace model for many organizations. Office space and infrastructures need the flexibility to adapt to change – SpaceLogic RP-V Advanced can be a part of EcoStruxure Building Operation which support the dynamic setup of the rooms.

Enhance occupant experience - beyond delivering comfort, today’s owners, tenants, and employees expect a building to provide a more interactive and engaging experience that supports

their well-being and productivity. SpaceLogic RP-V Advanced can be a part of Connected Room Solutions that connect lights, blinds and noise levels.

Reduce energy costs and support sustainability goals – today HVAC installations strive towards low system pressure and airflow. SpaceLogic RP-V Advanced´s new air flow sensor can measure very low differential pressures with high resolution, <0.02Pa, to ensure good performance.

24 of 25

Use Case: RP-V Advanced for a cybersecure environment

Confidential Property of Schneider Electric |

Page 24

.

Be in full control and limit the different device types that can be added to SpaceLogic RP-V via built-in whitelisting.

There are different levels of cyber security. SpaceLogic RP-V can sit under a private BACnet IP network in an architecture with SpaceLogic Automation Servers.

25 of 25