SpaceLogic RP-V Advanced
Part of EcoStruxureTM Connected Room Solutions
Value Proposition Presentation
© 2022 Schneider Electric. All Rights Reserved.
© 2021 Schneider Electric, All Rights Reserved | Page 2
Source: Global Building Stock Database 2Q20
The world of your building
The total building stock is estimated to grow to
124.7 billion m2
in 2029 from 102.9 billion m2.
Source:
1 Architecture 2030, 2020
2 Facts + Statistics: Global catastrophes, Insurance Information Institute, 2020
3 U.S. Environmental Protection Agency, 2020
4 Joseph G. Allen, Healthy Buildings Program, Harvard University, 2019
>350
natural + man-made �disasters in the world�in 20192
>30%
of the energy is�wasted in buildings3�
~40%
of the world’s�CO2 emission comes�from buildings1
~90%
of our time�is spent indoors4�
The world of your building
Hyper-efficient
Maximize performance by optimizing system and workflow
Resilient
Robustly withstand internal and external challenges
Sustainable
Consume less, extend life of assets, and spend wisely
People-centric
Ensure comfortable, productive setting for all people
The Foundation of Buildings of the Future
Hyper-efficient
Maximize performance by optimizing system and workflow
Resilient
Robustly withstand internal and external challenges
Sustainable
Consume less, extend life of assets, and spend wisely
People-centric
Ensure comfortable, productive setting for all people
SpaceLogicTM RP-V Advanced enables our vision for Buildings of the Future
Features and Capabilities
Confidential Property of Schneider Electric |
Page 6
Name | Universal Input/Output | SSR Outputs | Air Flow Sensor |
RP-V-4A | 4 | | 1 |
RP-V-5A | 2 | 3 | 1 |
Occupancy & CO2 Control of Variable Air Volume (VAV)
Results
Measuring occupancy levels results in a quicker response to change �than waiting for a rise in CO2, providing the best possible ventilation rates.
As the room empties and CO2 levels fall, VAV will modulate to minimum flow.
The AHU continuously tracks demand from all the system VAV boxes modulating fan speeds to maintain pressure levels in the supply and extract ducts.
2
1
AHU provides pre treated air to VAV box and the damper varies air flow to room diffuser.
VAV damper is controlled direct via the built in actuator in the RP-V Advanced. �Wired communication to Automation Server.
4
5
6
7
Wall sensor provides temp & CO2 data to RP-V.
Using data from sensors �and room occupancy design, VAV setpoint is scheduled between min-max flow.
As CO2 levels change, VAV box setpoint is rescheduled to meet the maximum CO2 requirements.
Ceiling mounted Multi Sensor or Insight-Sensor, provides occupancy count data
3
VAV modulates air volume in room, achieving desired setpoint
SpaceLogic RP-V Advanced is the IoT hub that enables demand control ventilation to create the Room of the Future
Did you know: Demand control ventilation practices driven by sensor data save 10-20% of building HVAC energy use1
1 Azizi, Olofsson, Nair; Demand-controlled energy systems in commercial and institutional buildings: a review of methods and potentials; Umea University, Sweden
Which do I choose?
Confidential Property of Schneider Electric |
Page 9
I’m looking for an entry-level model for a basic HVAC application
My building will only have BACnet MS/TP and I don’t plan to upgrade to IP
I need very basic variable air volume (VAV) HVAC control
EasyLogic
RP-V
SpaceLogic
RP-V Advanced
SpaceLogic
MP-V Pro
My project requires a room bus for Connect Room Solution,
and/or I plan to have connected lights, blinds, and Living Space sensors
My application requires the use of 2 RS-485 ports at the same time
My building uses ethernet / BACnet IP for communication
I need high load (1.5A) or DC capability on the DO
I need more I/O resources and expanded memory for a larger project and/or more advanced application
I need a premium CPU to host complex integrations
RP-V Advanced – Part of the SpaceLogic Range
Confidential Property of Schneider Electric |
Page 10
Confidential Property of Schneider Electric |
Page 11
EcoStruxureTM Connected Room Solutions creating the Room of the Future – now with RP-V Advanced
Confidential Property of Schneider Electric |
Page 12
Internal Communication - Ceiling
EcoStruxure
Building Commission
Mobile App
Internal Communication - Wall
RP-V Advanced
Room 1
Lighting
Blind
1-10v
Insight-Sensor
SMI
Physical IO
Room 2
1 x AS-P per floor
Room 3
1 x Enterprise Server per building
BACnet IP
BACnet IP
IP Backbone
Floor 1
Floor 2
1 x AS-P per floor
EcoStruxure Building Engage
Internal Communication - Ceiling
Internal Communication - Wall
RP-V Advanced
Lighting
Blind
1-10v
Insight-Sensor
SMI
Physical IO
Living
Space
Sensor
Remote �Control
EcoStruxureTM Connected Room Solutions with SpaceLogic RP-V Advanced: Architectural Diagram
SpaceLogic RP-V Advanced creates comfortable, productive Rooms of the Future using in a hyper-efficient and streamlined approach
Confidential Property of Schneider Electric |
Page 13
Seamless Integration
Out of the box integration with BMS eliminates 3rd parties and heavy engineering
Meet Tenant Demands
Achieve the right balance of wellbeing, comfort, and sustainability
Demand control ventilation for fresh air at the room level
Room-Level Control
Connected Room Solutions
A complete, modern, modular room solution from one innovative supplier
SpaceLogic RP-V Advanced creates comfortable, productive Rooms of the Future using in a hyper-efficient and streamlined approach
Confidential Property of Schneider Electric |
Page 14
Today: Floor Level Integration
Future: Room Level Integration
Confidential Property of Schneider Electric |
Page 15
Building Owner value: balance comfort with efficiency
Create demand-driven ventilation, reducing HVAC energy use when not actually needed
Modernize and meet future of digital smart buildings with minimal disruption
Achieve well-being and energy standards, like WELL, LEED and WiredScore more easily
Benefit from higher operational and energy efficiencies for increased building value and ROI
Integrate with lighting, blinds, and other devices to achieve sustainability and wellness
Confidential Property of Schneider Electric |
Page 16
Consultant Specifier value: high-end solution meets the needs of both owners and occupants
Provide a variable air volume (VAV) ventilation scheme for fresh air circulation
Create a flexible, future-proof design approach for long lasting building value
Achieve value-add energy and well-being standards such as WELL, LEED and WiredScore
Automatically reduce energy consumption with integration of electrical, lights, blinds, and HVAC
Offer an open, secure, scalable solution in a single architecture to win more work
Confidential Property of Schneider Electric |
Page 17
System Integrator value: seamless install, more opportunity
Provide a modern VAV solution that saves cost with quick install, integration, & commissioning
Grow profitability by winning more business with a highly differentiated solution
Increase project opportunities by offering an increased scope for Connected Room Solutions
Expand scopes with value-added features, rezoning flexibility, easy ladder-free upgrades
Use Case: Air quality as the control point
Confidential Property of Schneider Electric |
Page 18
.
Why ventilate when it´s not needed? The RP-V Advanced controller measures the air quality and adjust the air flow to create a healthy climate in balance with the demand.
Controlling the air volume depending on the occupancy level in the room is an approved method on the market and lets the AHU operate optimally and energy smart. The AHU doesn’t need to produce more treated air than required by the system.
Fits perfectly in conference rooms and office spaces that have variations in the number of people occupying the area.
Use Case: Flexible and Modular Workplace
Confidential Property of Schneider Electric |
Page 19
.
Mobile cubicle walls gives the user the possibility to change and customize the meeting space on-the-fly, but it also puts great demands on the HVAC system which is often designed for a static setup of the rooms
SpaceLogic RP-V Advanced can be a part of EcoStruxure Building Operation which supports the dynamic setup of the rooms.
As an example, a digital input from a folding wall can trigger a function that includes several RP-Vs to work as one room controller, minimizing the risk of counteracting against each other causing unwanted energy usage.
Use Case: Connected room with RP-V Advanced
Confidential Property of Schneider Electric |
Page 20
.
Integration of HVAC, light and blinds as separate systems doubles installation and commissioning efforts. Units with over-bridging functionality from different vendors involve complex planning, multiple user interfaces and potential sources of error. Using ONE system with EcoStruxure Building Operation and SpaceLogic overcomes these problems.
Occupants’ cognitive abilities, health, productivity and well-being, are directly impacted by decisions in engineering, operations and the running of buildings. EcoStruxure Building Operation with Connected Room Solutions, does not only offer demand driven VAV zones, but also integration of light, blind and noise level. All pieces together, will allow for optimal occupant comfort and a well-being experience.
In addition to above, the available building IoT data and ownership of this, will also become clearer when integrating into ONE system.
EcoStruxure Building Operation connecting to the Edge level down to zone level, allows the building owner to change layout and re-zoning when changes.
Use Case: Quick installation with RP-V Advanced
Confidential Property of Schneider Electric |
Page 21
.
Avoid starting the design work from scratch and download quality-proven standard VAV applications that comply with ASHRAE 36 standard.
The built-in isolated power supply will minimize the self power consumption which could be a significant factor when creating energy-optimized spaces. It also allows the installer to use a centralized transformer solution instead of wiring one to each unit.
SpaceLogic RP-V Advanced acts as the IoT hub in the room space areas, both wired and wireless. Perform fast retrofit and replace the old room unit with a new wireless unit and avoid time-consuming re-wiring.
Start commissioning before the network cable infrastructure is in place by using the EcoStruxure Building Commission app. Perform checkout, configure set-points and save reports.
Use Case: Service your system
Confidential Property of Schneider Electric |
Page 22
.
Tools to make migration easy. Quickly configure, customize and duplicate applications.
SpaceLogic RP-V Advanced supports both BACnet IP and MS/TP enabling easy integration on existing infrastructure to minimize cost.
Mechanically compatible with B3, MNB, MNL and TAC 102 range of VAV controllers making exchange easy and strait forward.
Support for Zigbee enables replacement of existing room units to Zigbee based room units, without re-wiring.
Use Case: Modernize your system
Confidential Property of Schneider Electric |
Page 23
.
Improve space utilization - the ‘new normal’ is a hybrid workplace model for many organizations. Office space and infrastructures need the flexibility to adapt to change – SpaceLogic RP-V Advanced can be a part of EcoStruxure Building Operation which support the dynamic setup of the rooms.
Enhance occupant experience - beyond delivering comfort, today’s owners, tenants, and employees expect a building to provide a more interactive and engaging experience that supports
their well-being and productivity. SpaceLogic RP-V Advanced can be a part of Connected Room Solutions that connect lights, blinds and noise levels.
Reduce energy costs and support sustainability goals – today HVAC installations strive towards low system pressure and airflow. SpaceLogic RP-V Advanced´s new air flow sensor can measure very low differential pressures with high resolution, <0.02Pa, to ensure good performance.
Use Case: RP-V Advanced for a cybersecure environment
Confidential Property of Schneider Electric |
Page 24
.
Be in full control and limit the different device types that can be added to SpaceLogic RP-V via built-in whitelisting.
There are different levels of cyber security. SpaceLogic RP-V can sit under a private BACnet IP network in an architecture with SpaceLogic Automation Servers.