NORTH ANDOVER PROPOSED PROJECTS �AS PART OF FACILITIES MASTER PLAN II
PUBLIC FORUMS
1
Welcome/Introductions
2
3
Facilities Master Plan I Projects
Department of Public Works
Anne Bradstreet Early Childhood Center
Kittredge Elementary School
North Andover Town Hall
School Administration Building
North Andover Fire Department
Senior Community Center
FACILITIES MASTER PLAN II - PROJECTS
4
FACILITIES MASTER PLAN II - SCHOOL PROJECTS
5
Building Assessments
6
Equity - School Capacity Analysis
7
Kittredge Elementary School
Kittredge Elementary School
INTERIOR & EXTERIOR NON COMPLIANT ADA ACCESS /EGRESS
WATER INFILTRATION
NON ADA FIXTURES
ORIGINAL STEAM HEAT
ORIGINAL ELECTRICAL COMPONENTS
Kittredge Space Analysis
10
Room Type | Existing Rooms | Current Sq. Ft. | Planned Rooms | MSBA Guidelines for Sq. Ft. | Additional Sq. Ft. |
Classrooms | 12 | 10,800 | 20 | 19,000 | 8,200 |
Art | 1 | 700 | 1 | 1,000 | 300 |
Music | 0 | 0 | 1 | 1,200 | 1,200 |
Reading | 1 | 140 | 1 | 500 | 360 |
Cafe/Kitchen | 1 | 1,680 | 1 | 2,600 | 920 |
Gym | 1 | 5,820 | 1 | 6,000 | |
Library/Media Ctr | 1 | 1,140 | 1 | 2,020 | 880 |
Support Spaces | 6 | 965 | 8 | 2,500 | 1,535 |
Special Education | 3 | 1,050 | 3 | 2,850 | 1,800 |
Nurse | 1 | 250 | 1 | 410 | 160 |
OT/PT | 1 | 220 | 2 | 800 | 580 |
Atkinson Elementary School
Atkinson Elementary School
NON ADA HARDWARE & CLEARANCES
ROOF FAILING & AREAS NOT PROPERLY DRAINING
NON ADA TOILETS AND CLEARANCES
NON COMPLIANT VERTICAL ACCESS
ORIGINAL OUTDATED ELECTRICAL COMPONENTS
Atkinson Space Analysis
13
Room Type | Existing Rooms | Current Sq. Ft. | Planned Rooms | MSBA Guidelines for Sq. Ft. | Additional Sq. Ft. |
Classrooms | 14 | 13,300 | 20 | 19,000 | 5,700 |
Art | .5 | 530 | 1 | 1,000 | 470 |
Music | .5 | 530 | 1 | 1,200 | 670 |
Reading | 1 | 300 | 1 | 500 | 200 |
Cafe/Kitchen | 1 | 4,672 | 1 | 2,600 | |
Gym | 1 | 5,840 | 1 | 6,000 | |
Library/Media Ctr | 1 | 925 | 1 | 2,020 | 1,095 |
Support Spaces | 4 | 1,126 | 8 | 2,500 | 1,374 |
Special Education | 2 | 1,200 | 3 | 2,850 | 1,650 |
Nurse | 1 | 240 | 1 | 410 | 170 |
OT/PT | 1 | 350 | 2 | 800 | 450 |
Franklin Elementary School
Franklin Elementary School
NON ADA FIXTURES
NON ADA ENTRANCE/EXIT
ORIGINAL DOORS /NON ADA HARDWARE & CLEARANCES
ORIGINAL VAT FLOORING
OUTDATED ELECTRICAL
COMPONENTS
Franklin Space Analysis
16
Room Type | Existing Rooms | Current Sq. Ft. | Planned Rooms | MSBA Guidelines for Sq. Ft. | Additional Sq. Ft. |
Classrooms | 19 | 17,100 | 25 | 23,750 | 6,650 |
Art | 1 | 500 | 1 | 1,000 | 500 |
Music | 1 | 650 | 1 | 1,200 | 550 |
Reading | 0 | 0 | 1 | 500 | 500 |
Cafe/Kitchen | 1 | 2,520 | 1 | 2,600 | |
Gym | 1 | 1,750 | 1 | 6,000 | 4,250 |
Library/Media Ctr | 1 | 1,760 | 1 | 2,020 | |
Support Spaces | 4 | 1,040 | 8 | 2,500 | 1,460 |
Special Education | 2 | 1,800 | 3 | 2,850 | 1,050 |
Nurse | 1 | 200 | 1 | 410 | 210 |
OT/PT | 2 | 300 | 2 | 800 | 500 |
North Andover Middle School
North Andover Middle School
MISCELLANEOUS NON ADA ITEMS
MISCELLANEOUS ROOF REPAIRS AND REPLACEMENT REQUIRED
MASONRY & LINTEL REPAIR REQUIRED @ 1953 ADDITION
Enrollment Projections
19
Enrollment Data and Projection
RECOMMENDATION
21
22
Kittredge Project
23
24
Kittredge Elementary School
Atkinson Project
25
26
Atkinson Elementary School
Franklin Project
27
28
Franklin Elementary School
Middle School Project
29
30
North Andover Middle School
ABECC Project
31
32
ABECC
33
Fire Station #2
34
Youth Center
Facilities Master Plan II Working Group
Laurie Burzlaff
Steve Foster
Paul Hutchins
Jim Mealey
Lyne Savage
Jim Stanford
35
PUBLIC FORUM SCHEDULE
36
Process Timeline
37
Comments to date...
38
QUESTIONS???
39