BEE STANDARDS & LABELING PROGRAM�
1
BEE STAR LABLING SCHEME
August 10, 2023 | Slide 2
Dr. BG DESAI
BUREAU OF ENERGY EFFICIENCY HAS ISSUED STAR LABLING SCHEME FOR FOLLOWING EQUIPMENTS
Mandatory Scheme | |
1 | Frost Free Refrigerator |
2 | Stationary Storage Type Electric Water Heater |
3 | Colour Television |
4 | Room Air Conditioner (Variable Speed) |
5 | TFL |
6 | LED LAMPS |
7 | Light Commercial AC Fixed Speed |
8 | Deep Freezers |
9 | Ultra-High Definition (UHD) Televisions |
10 | Room Air Conditioner (Fixed Speed) |
11 | RAC (Cassette, Floor Standing Tower, Ceiling, Corner AC) |
12 | Distribution Transformer |
13 | Direct Cool Refrigerator |
14 | Ceiling Fan |
BEE HAS ALSO ISSUED STAR LABLELING FOR OFFICE BLDGS.
BUREAU OF ENERGY EFFICIENCY HAS ISSUED STAR LABLING SCHEME FOR FOLLOWING EQUIPMENTS
Voluntary Scheme | |||
1 | General Purpose Industrial Motor | 13 | Solar Water Heater |
2 | Submersible Pump Set | 14 | Air Compressors |
3 | Domestic Gas Stove | 15 | High Energy Li-Battery |
4 | Washing Machine (Semi/Top Load/Front Load) | 16 | Tyres/Tires |
5 | Computer | 17 | Side by Side/Multi Door Refrigerator |
6 | Ballast | 18 | Pedestal Fan |
7 | Office Automation Products | 19 | Table/Wall Fan |
8 | Diesel Engine Driven MonosetPumps for Agricultural Purposes | 20 | Induction Hob |
9 | Solid State Inverter | | |
10 | Diesel Generator Set | | |
11 | Chillers | | |
12 | Microwave Oven | | |
| | | |
BEE HAS ALSO ISSUED STAR LABLELING FOR OFFICE BLDGS.
BUREAU OF ENERGY EFFICIENCY - STAR LABLING SCHEME
August 10, 2023 | Slide 5
FROST FREE (NO FROST) REFRIGERATOR
COOLING IS PROVIDED BY FORCED AIR CIRCULATION.
AUTOMATIC OPERATION TO PREVENT FORMATION OF FROST ON REFRIGERATED SURFACES.
NO ACCUMULATION OF ICE ON STORED FOOD.
REF STARNDARD AS/NZS 4474.1.1997
AS/NZS 4474.2.2001
IS 15750:2006.
TOTAL ADJUSTED VOLUME = FRESH FOOD STORAGE (30C)
+1.62 FREEZER VOLUME (-150C)
STAR RATING SCHEME
CONSUMPTION = Knf X Vad + Cnf
= (KWH / YEAR)
WHERE,
Knf = CONSTANT MULTIPLIER (KWH / LTR / YEAR)
Vad = TOTAL ADJUSTED STORAGE VOLUME (LTR)
Cnf = CONSTANT FIXED ALLOWANCE (KWH / YEAR)
STAR RATING SCHEME� Frost Free Refrigerator �(Valid from 1st January, 2023 to 31st December, 2024)�
August 10, 2023 | Slide 8
STAR RATING | Annual Energy Consumption (kWh/year) |
1 STAR * | (0.157* Vtot+243) ≤ AEC < (0.180* Vtot+279) |
2 STAR ** | (0.136*Vtot+211) ≤ AEC < (0.157* Vtot+243) |
3 STAR *** | (0.118*Vtot+184) ≤ AEC < (0.136* Vtot+211) |
4 STAR **** | (0.103* Vtot +160) ≤ AEC < (0.118*Vtot +184 |
5 STAR ***** | AEC < (0.103*Vtot+160) |
STAR RATING SCHEME �Direct Cool Refrigerator� (Valid from 1st January, 2023 to 31st December, 2024)
August 10, 2023 | Slide 9
STAR RATING | Annual Energy Consumption (kWh/year) |
1 STAR * | (0.115* Vtot+179) ≤ AEC < (0.129* Vtot+201) |
2 STAR ** | (0.103* Vtot+160) ≤ AEC < (0.115* Vtot+179) |
3 STAR *** | (0.091*Vtot +141) ≤ AEC < (0.103* Vtot+160) |
4 STAR **** | (0.080*Vtot+124) ≤ AEC < (0.091*Vtot +141) |
5 STAR ***** | AEC < (0.080*Vtot+124) |
FOR 280 LITRE REFRIGERATOR - FROST FREE��CONSUMPTION = Knf X Vad + Cnf � = (KWH / YEAR)��
August 10, 2023 | Slide 10
01 January 2014 to 31 December 2015
1 STAR = 0.4463 x 280 + 389 = 128+ 389 = 514 (KWH / YEAR)
3 STAR = 0.2856 x 280 + 249 = 80 + 249 = 329 (KWH / YEAR)
5 STAR = 0.1828 x 280 + 159 = 51+ 159 = 210 (KWH / YEAR)
01 January 2016 to 31 December 2018
1 STAR = 0.3570 x 280 + 311 = 100+ 311= 411 (KWH / YEAR)
3 STAR = 0.2285 x 280 + 199 = 64 + 199 = 263 (KWH / YEAR)
5 STAR = 0.146 x 280 + 127 = 41+ 127 = 168 (KWH / YEAR)
FOR 280 LITRE REFRIGERATOR - FROST FREE��CONSUMPTION = Knf X Vad + Cnf= (KWH / YEAR)��
August 10, 2023 | Slide 11
1st January, 2023 to 31st December, 2024
1 STAR = 0.157 x 280 + 243 = 287 (KWH / YEAR)
3 STAR = 0.118 x 280 + 184 = 244 (KWH / YEAR)
5 STAR = 0.103 x 280 + 160 = 189 (KWH / YEAR)
1st January, 2023 to 31st December, 2024
1 STAR = 0.115 x 280 + 179 = 211 (KWH / YEAR)
3 STAR = 0.091 x 280 + 141 = 166 (KWH / YEAR)
5 STAR = 0.080 x 280 + 124 = 146 (KWH / YEAR)
FOR 280 LITRE REFRIGERATOR - Direct Cool Refrigerator
TUBULAR FLUORESCENT LAMP
August 10, 2023 | Slide 12
IS 2418 (PART I & PART II)-1977 WITH ALL AMMENDMENTS
1200 mm TFL UPTO 40 WATTS
6500 0K, FOR HALO PHOSPHATE
6500 0K, 4000 0K, 2700 0K FOR TRI PHOSPHATE
LUMEN EFFICIENCY VALUES TO BE TESTED UPTO 3500 HRS.
TUBULAR FLUORESCENT LAMP
August 10, 2023 | Slide 13
| 1 STAR | 2 STAR | 3 STAR | 4 STAR | 5 STAR |
LUMENS / WATT @ 100HRS | < 61 | ≥61 <67 | ≥67 <86 | ≥86 <92 | ≥92 |
LUMENS / WATT @ 2000HRS | < 52 | ≥52 <57 | ≥57 <77 | ≥77 <83 | ≥83 |
LUMENS / WATT @ 3500HRS | < 49 | ≥49 <54 | ≥54 <73 | ≥73 <78 | ≥78 |
ROOM AIR CONDITIONER
August 10, 2023 | Slide 14
SPLIT AND UNITARY SINGLE PHASE UNITS UPTO 11kW,
IS 1391 PART 1 AND PART 2 WITH ALL AMMENDMENTS,
ENERGY EFFICIENCY RATIO = COOLING CAPACITY
(EER) POWER CONSUMPTION
COOLING CAPACITY IN WATTS
1 TON REFRIGEARATION COOLING CAPACITY = 3515WATTS
POWER CONSUMPTION IN WATTS
STAR RATING SCHEME - Split type air conditioners �(01-01-2021 to 31-12-2023 )
August 10, 2023 | Slide 15
LABLING | EER | W/W |
MIN | MAX | |
1 STAR | 3.3 | 3.49 |
2 STAR | 3.5 | 3.79 |
3 STAR | 3.8 | 4.39 |
4 STAR | 4.4 | 4.99 |
5 STAR | 5.0 | |
EXAMPLE - AIR CONDITIONING
August 10, 2023 | Slide 16
COOLING CAPACITY = 1.5 TON
1.5 x 3515 = 5272 WATTS
1 STAR EER = Cooling Capacity
Power Consumption
1 STAR EER = 3.3
COOLING CAPACITY = 5272 Watts
Power Consumption = 5272
3.3
= 1598 Watts.
01-01-2021 to 31-12-2023
EXAMPLE - AIR CONDITIONING
August 10, 2023 | Slide 17
COOLING CAPACITY = 1.5 TON
1.5 x 3515 = 5272 WATTS
5 STAR EER = Cooling Capacity
Power Consumption
= 4.5
= 5272 Watts
Power Consumption
Power Consumption = 5272
5
= 1054 Watts.
5 Star Air Conditioner consumes 30% less electricity
than 1 Star Air Conditioner
01-01-2021 to 31-12-2023
-
DISTRIBUTION TRANSFORMER
August 10, 2023 | Slide 18
OIL IMMERSED NATURAL AIR COOLED NON SEAL TYPE,
IS: 1180 WITH UPDATES
IS: 2026 WITH UPDATES
IS: 2500 WITH UPDATES
RATINGS 16, 25, 63, 100, 160, 200kVA @ 11kV
TOTAL LOSSES AT 50% AND 100% LOADING,
BEE STAR LABEL� � TOTAL LOSSES (WATTS)
August 10, 2023 | Slide 19
RATED kVA | 1 STAR | 3 STAR | 5 STAR | |||
50% | 100% | 50% | 100% | 50% | 100% | |
16 | 200 | 555 | 150 | 480 | 120 | 400 |
25 | 290 | 785 | 210 | 695 | 175 | 595 |
63 | 490 | 1415 | 380 | 1250 | 300 | 1050 |
100 | 700 | 2020 | 520 | 1800 | 435 | 1500 |
160 | 1000 | 2800 | 770 | 2200 | 570 | 1700 |
200 | 1130 | 3300 | 890 | 2700 | 670 | 2100 |
20
Effective from July 2017
21
Effective from July 2017
CEILING FANS
August 10, 2023 | Slide 22
STANDARD = IS: 374-1979 WITH ALL UPDATES
PARAMETER = AIR DELIVERY, FAN SPEED, POWER INPUT
SERVICE VALUE = AIR DELIVERY (m3/min)
POWER IN WATTS
APPLICATION = 1200 MM FAN
MIN AIR DELIVERY = 210 (m3/min)
CEILING FANS��STAR LABELING SCHEME
August 10, 2023 | Slide 23
STAR RATING | Rated Service Value (Cubic meter per minute/Watt) |
1 STAR | ≥ 4.0 to < 4.5 |
2 STAR | ≥ 4.5 to < 5.0 |
3 STAR | ≥ 5.0 to < 5.5 |
4 STAR | ≥ 5.5 to < 6.0 |
5 STAR | ≥ 6.0 |
BIS service value 3.5 from the year 2010
Valid from the 1st July, 2022 to 31st December, 2024
CEILING FANS��STAR LABELING SCHEME
August 10, 2023 | Slide 24
1 STAR RATINGSERVICE VALUE = 4
POWER CONSUMPTION = AIR DELIVERY
SERVICE VALUE
= 210 = 53 (Watts)
4
5 STAR RATING SERVICE VALUE =6
POWER CONSUMPTION = AIR DELIVERY
SERVICE VALUE
= 210 = 35 (Watts)
6
LPG STOVES **
August 10, 2023 | Slide 25
STAR RATING | THERMAL EFFICIENCY |
ONE | If Thermal efficiency ≥ 68% &<72% |
TWO | If Thermal efficiency ≥ 72% &<75% |
THREE | If Thermal efficiency ≥ 75% &<78% |
FOUR | If Thermal efficiency ≥ 78% &<81% |
FIVE | If Thermal efficiency≥ 81% |
IS: 4246-2002
THERMAL EFFICIENCY TO BE DETERMINED,
SHOULD NOT BE LESS THEN 64%.
**
VARIABLE CAPACITY AIR CONDITIONERS
Indian Seasonal Energy Efficiency Ratio (kWh/kWh) | ||
Star Rating | Minimum | Maximum |
1 Star | 2.5 | 2.69 |
2 Star | 2.7 | 2.89 |
3 Star | 2.9 | 3.09 |
4 Star | 3.1 | 3.29 |
5 Star | 3.3 | |
Indian Seasonal Energy Efficiency Ratio (kWh/kWh) | ||
Star Rating | Minimum | Maximum |
1 Star | 3.1 | 3.29 |
2 Star | 3.3 | 3.49 |
3 Star | 3.5 | 3.99 |
4 Star | 4.0 | 4.49 |
5 Star | 4.5 | |
(b) Star Rating Plan –(From 1st January, 2018 to 31st December, 2020)
VARIABLE CAPACITY AIR CONDITIONERS
Indian Seasonal Energy Efficiency Ratio (kWh/kWh) | ||
Star Rating | Minimum | Maximum |
1 Star | 2.7 | 2.89 |
2 Star | 2.9 | 3.09 |
3 Star | 3.1 | 3.29 |
4 Star | 3.3 | 3.49 |
5 Star | 3.5 | |
Indian Seasonal Energy Efficiency Ratio (kWh/kWh) | ||
Star Rating | Minimum | Maximum |
1 Star | 3.3 | 3.49 |
2 Star | 3.5 | 3.99 |
3 Star | 4.0 | 4.49 |
4 Star | 4.5 | 4.99 |
5 Star | 5.0”; | |
(b) Star Rating Plan –(From 1st January, 2021 to 31st December, 2023)
LED LAMPS
Star Rating | Rated Luminous Efficacy (lumen/Watt) |
1 | ≥ 68 & < 79 Freeze |
2 | ≥79 & < 90 |
3 | ≥ 90 & < 105 |
4 | ≥ 105 & < 120 |
5 | ≥ 120 |
Star Rating | Rated Luminous Efficacy (lM/Watt) |
1 | ≥79 & < 90 Freeze |
2 | ≥ 90 & < 105 |
3 | ≥ 105 & < 120 |
4 | ≥120 & < 135 |
5 | ≥135.”; |
(b) Star Rating Plan –Mandatory
Validity: 1st July, 2020 to 30th June, 2023
Name of the Scheme / Programme | Energy Saving | Total Savings (Mtoe) | Emission Reduction (MtCO2 | Monetary Saving (INR Crore) | ||
Thermal (Mtoe) | Electrical (BU) | |||||
PAT Scheme | Demand Side Sector | 5.901 | 7.064 | 6.509 | 25.529 | 14391 |
Supply side sectors- TPP, DISCOMs7 & Refineries | 5.192 | 23.215 | 7.189 | 36.371 | 20014 | |
MSMEs | BEE-SME Programme | 0.001 | | 0.001 | 0.004 | 2 |
BEEE-UNIDO-GEF Programme | 0.009 | | 0.009 | 0.047 | 16 | |
BEE-WB-GEF Programme | 0.012 | | 0.012 | 0.073 | 22 | |
Standards and Labelling Programme | | 55.693 | 4.790 | 45.668 | 27846 | |
UJALA Programme Saving other than UJALA LED deployment progm not considered | | 44.645 | 3.839 | 36.609 | 22323 | |
ECBC – Commercial buildings programme | | 0.040 | 0.003 | 0.033 | 20 | |
BEE Star rating buildings | | 0.083 | 0.007 | 0.068 | 41 | |
Building Energy Efficiency Programme | | 0.110 | 0.009 | 0.090 | 55 | |
Other green building Programmes | | 0.070 | 0.006 | 0.057 | 35 | |
MuDSM (Street Lighting Programme) | | 5.647 | 0.486 | 4.631 | 2824 | |
AgDSM* (Star Rated Pumps) | | 0.18 | 0.015 | 0.148 | 90 | |
Corporate Average Fuel Economy (CAFE) | 0.848 | | 0.848 | 2.650 | 1560 | |
FAME-I Scheme | 0.038 | | 0.038 | 0.070 | 70 | |
TOTAL | 12.000 | 136.374 | 23.728 | 151.741 | 89,122 | |
A Report on Impact of Energy Efficiency Measures,2018-19 : Summary of Energy Saving (2018-19)
30
THANK YOU
31
DR. BG DESAI
46, ATMA JYOTI NAGAR, VADODARA – 390023
PHONE: 0265 2396243, MAIL: madhvi007@rediffmail.com
ACADEMIC
M.E. ELECTRICAL – GUJARAT UNIVERSITY
Ph.D. - IIT BOMBAY,
PROFESSIONAL
FACULTY – IIT BOMBAY (1963-1968)
R & D MANAGER – JYOTI LTD. (1969-1975)
FOUNDER DIRECTOR & CHAIRMAN (1975-2005)
DEVKI R & D, DEVKI ENERGY CONSULTANCY PVT LTD.
RETIRED IN 2005, WORKING FOR PROMOTION OF ENERGY CONSERVATION
SR. MEMBER IEEE,
FELLOW INSTITUTE OF ENGINEERS
32
Late Shri J.S.Rana
Address:
5, Sarita Sangam, Near Rajesh Appartment, Gotri Road,
Vadodara- 390023. Phone: 0265 - 2397554
Academic:
B.E. Electrical
M.E. Electrical
Professional:
Faculty – L.D.Engeenering College (1959-1965)
R & D Manager – Jyoti Ltd. (1965-1983)
Consultant in the field of Power Electronics & Energy
Conservation (1983 – 2005)
Director Devki Energy (1990 – 2005)
Since 2005 working for promotion of Energy Conservation
33
Community Science Centre, Vadodara (CSC) is a non-profit charitable trust established in 1982 by leading citizens, corporate bodies, and charitable trusts of Baroda. It has been recognized by GUJCOST (Gujarat Council on Science and Technology) as a Regional Science Centre. The objective of the centre is to promote dissemination of knowledge in Science and Technology to our urban and rural communities, particularly to the children. The centre is organising various activities and programmes on regular basis, such as celebration of National Science Day, Educational tours, Science Exhibitions, Quiz, Elocution competition etc. It also conducts vacation programmes, popular lectures, model making workshops, work shop for teachers, various regular activities in Science club, Computer club, Astronomy club, Garden club, Maths club and Aero Modelling. We also conduct out reach programmes on health and hygiene, science and superstition, modern technologies in agriculture, organic farming, etc.
Acknowledgement
For helping in preparation of this Power Point Presentation
34