1 of 21

Single molecule electrical recording and fluorescence-force spectroscopy

2 of 21

Many flavors of single molecule techniques

Force

Electrical

Fluorescence

In silico

3 of 21

All-atom molecular dynamics (MD) simulations:

the computational microscope

Atoms move according to

classical mechanics (F=ma)

Interaction between atoms is

defined by molecular force field

Massive parallel computer

> 200,000 CPUs

Time scale: ~ 0.1-100 μs

Size scale: 10K - 100M atoms or (< 50 nm)3

Time resolution: 2 fs

Spatial resolution: 0.1 A

4 of 21

Patch Clamp Technique

Single channel current

The Nobel Prize in Physiology or Medicine 1991Erwin Neher, Bert Sakmann

for their discoveries concerning "the function of single ion channels in cells".

5 of 21

MD simulations of α-hemolysin

Instantaneous current

Biophys. J. 88:3745 (2005)

slides from Alek Aksimentiev @UIUC

6 of 21

Current-voltage curve of α-hemolysin

Instantaneous current

Ionic current at 120mV:

Experiment: 120 pA

Simulations: 130 pA

Biophys. J. 88:3745 (2005)

slides from Alek Aksimentiev @UIUC

7 of 21

The ionic current blockade may reveal

the sequence of the confined nucleotides

Sequencing DNA by measuring ionic current

Nature Reviews Drug Discovery 1, 77-84 (January 2002)

This did not become a reality until ten years later. Why?

8 of 21

Oxford Nanopore Technologies

MinION: ~800 parallel detection wells

Read length: up to 100,000 nucleotides

A pore protein with a narrow constriction

DNA helicase

Accuracy: 96%

9 of 21

10 of 21

NANOPORE SEQUENCING

https://nanoporetech.com/applications/dna-nanopore-sequencing

  • Most other sequencing methods (Sanger, Illumina, PacBio etc) use sequencing by synthesis
  • Nanopore sequencing here uses sequencing by translocation

11 of 21

Need for measuring multiple observables

  • Traditionally, measure one quantity from a single molecule or one number as a function of time
    • Ion channel: current vs time
    • Magnetic tweezers: extension vs time
    • FRET: distance vs time
  • But, biology is complex and measuring a single observable may not give us enough information

12 of 21

Hybrid single-molecule techniques

Fluorescence

Force

Electrical

In silico

13 of 21

Myosin

Power-stroke

Fluorescent

ATP

Time (s)

14 of 21

optical tweezers

measure conformational change via fluorescence

as a function of applied force.

prior works: Yanagida, Kinosita, Block, Lang, Liphardt, …

single molecule FRET

Ha,…, Selvin, Weiss PNAS (1996)

Sungchul Hohng et al, science (2007)

15 of 21

  • 3’ to 5’ DNA helicases
  • a poor unwinder

Rep/UvrD/PcrA helicases

-what is the functional form?

-closed vs open

-how is unwinding regulated?

closed

open

Comstock et al, nature methods (2011)

Comstock et al, science (2015)

FRET

velocity (bp/s)

16 of 21

Single-Molecule Fluorescence

17 of 21

Single-Molecule Fluorescence

Introduce kymograph in a separate slide

18 of 21

C-Trap G2

Force-Fluorescence Correlative Measurements

19 of 21

Laminar flow microfluidics

  • Flow in all the reagents and move between them
  • Construct the single-molecule assay directly in situ
  • Speed, ease and reproducibility

CONFIDENTIAL

20 of 21

CONFIDENTIAL

21 of 21

kymograph