1 of 1

Markerless computer vision demonstrated excellent agreement with manual stopwatch measurements.

  • In clinical practice, mobility and balance assessments are traditionally timed manually using a stopwatch, which can introduce observer error and variability between assessors.
  • Marker-based motion capture systems can improve objectivity, but often require expensive equipment and specialized settings, limiting clinical accessibility.
  • Markerless computer vision (MLCV) motion capture offers a low-cost, objective alternative that may improve the consistency and efficiency of clinical assessments.
    • MLCV also has potential applications in telerehabilitation.
  • Before clinical implementation, MLCV-derived measurements must demonstrate agreement with conventional assessment methods.

Background

Methods

Results: ICC

PRESENTER

Nabiha Chowdhury

Nabiha Chowdhury, Julia Raphael, Dr. Bok kyu Kim, PhD, PT

Department of Physical Therapy, SUNY Upstate Medical University 

Summer Undergraduate Research Fellowship Program (SURF) 2026 

These findings support the feasibility of MLCV as an objective method for timing functional mobility assessments.

Secondary analysis of a pilot study testing the effects of taekwondo on balance and mobility

  • N= 14
    • 11 non-disabled older adults
    • 3 older adults with Parkinson's disease
  • Data were collected across multiple assessment timepoints, with two trials completed for each functional outcome measure

Participants completed four functional outcome measures

  • Five Times Sit-to-Stand (5XSTS)
  • Figure-8 Walk Test (F8WT)

Performance was recorded simultaneously using a high-resolution, high-speed action camera and a manual stopwatch.

Reference Measurements

Manual stopwatch measurements were collected during live testing (LT) and video review (VR).

Markerless Computer Vision Analysis

Video recordings were analyzed using an MLCV algorithm to automatically detect movement events and calculate task completion times.

Data Analysis

Agreement between measurement methods was evaluated using:

  • Intraclass Correlation Coefficient (ICC)
  • Bland–Altman analysis

Computer vision (CV) and LT were each compared with VR, which served as the gold standard.

Results: Bland-Altman Analysis

Tap or take a picture for the full poster and paper!

Video Review vs. Live Testing

Video Review vs. Computer Vision

5XSTS

F8WT

 

VR vs. LT

VR vs. CV

5XSTS

0.961

0.980

F8WT

0.935

0.755