Orientation
For AHNH AA
Tips in NDH OT
Contact Numbers
Meal Breaks
Sick Leave Procedure
Black Rainstrom warning/ Typhoon signal No. 8 or above before 8:00 (working hour)
每日入OT房:�
1)房燈較到最光
2)開抽癈氣系統
3)檢查房間溫度是否正確:溫度維持21-22,濕度50
4) 麻醉機做self test、ecg、 Spo2, BP cable 齊不齊,準備BP cap, dag, velband
5)要check監察用monitor係不係揀咗成人、BP每5分鐘量一次(每逢星期一要discharge 麻醉機資料)
6)check OT床
7)檢查插喉車工具
8)準備第一個case 要準備麻醉用品、set水
9)檢查麻醉房麻醉用品、要檢查OT 房藥車、暖櫃、打豆車物品
TOP-UP Store
All the above items can be ordered in 點心紙 and refilled by central pool.
Store 7
沿洗手間對出走廊直行
Bay 2 (後街)
Bay 2 (後街)
Glidescope
Optiflow
Trachway
Diffucult Intubation Trolley (DIT)
Holding
Sterile Core
(Outside OT 7)
Paediatric Trolley
E-trolley
Sterile core
(outside OT6)
RR
Standby @ RR
Sterile core (Anaes有關物品放在OT7 門外貨架)
ANA0007 - SA/RA/EA
ANA0008 - CVP
小黃腰兜 - CVP
DL Blade & Magill Forceps
ICU (near OT 10)
GA trolley
1)麻醉科細枕頭
2 ) Artery
3)綠紗布
4 Mask
5)DL/VL
6)jelly
7)ETTube/ LMA
8)20 ml syringe
9)貼眼膠布、Durapore
10)Pressure Gauge
11)探熱計
SA
SA equipment
EA/CSE
EA/ CSE set
NR fit 18G portex EA | NR fit 18G Portex CSE | Non NR fit B Braun 18G CSE | NON NR 18G EA in Bay C SA trolley | non NR Extra long 16G portex |
NR fit trolley Bay A &F | NR fit trolley Bay A &F | Bay B | Bay C spinal trolley | Bay B |
| | | | |
NR Fit Trolley Non NR fit CSE set
Bay A & F
Bay B
RA
(Except Bay D)
RA
Continuous Never Block Set
Single shot needle
RA pressure monitor
USG in OT
LOGIQ Totus BAY B | Samsung V5 Bay C | Venue Go Bay E | GE LOGIQ e Bay F |
| | | |
ETCO2 monitoring in Primus
ETCO2 monitoring in Primus
ETCO2 monitoring in Atlan A350
Zeus IE checking
Zeus IE checking
•https://sites.google.com/view/ndhot-ana/equipment/anaesthetic-machine?authuser=0
•Reference guide:
•https://drive.google.com/file/d/1EVeWYQQ9AcVuPABROtf-V_g8Ft4-NIhY/view
•AGSS floating ball
•D size O2
•Vaporizer if <50% cannot pass leak test
•Test cylinder → Press “test info” to check
•Check O2 flush (2 button)à change circuit outlet to à
•Breathing bag have sensor à downward position
•APL 20
•Sodalime have filter (change everymonth)
•Suction filter chane every 3 month
•Y piece put in designate site for checking
Train of Four (TOF)
� Assessment of Neuromuscular Blockade�
INNERVATOR NS252 | TOFSCAN | TOF3D |
| | |
Location:
H’stix & I-stat & Haemocue
H’stix | Istat Alinity | Haemocue |
| | |
2 sets in RR | 2 set in RR
| RR and each bay |
Temp monitoring
Syringe pump
Anaesthesia monitoring
New
Old
Lidco Monitor
Optiflow
Warming mattress
Hot dog | Alpha core inditherm | Astopad |
| | |
Switch on before connecting cable | | X ray case cannot use |
EMMA PCG capnography
12-Lead ECG
Maximo
Normal Maximo
Maximo with Hb function
LUCAS
Bair Hugger
Blood warmer
Acute pain control device
Epidural
Lignocaine infusion
PCA
Ketamine infusion
Acute pain control device
PCA | Ligocaine | Epidural | Ketamine infusion |
| | | |
Paed mattress
Troop Pillow
MTP trolley
- Next to SC E trolley
Syringe pump
Positioner
各OT theatre 內Intubation trolley 下層
各OT theatre 門外
Positioner
Bay A
Positioner
Bay B
Positioner
Bay C
Positioner
Positioner
Bay F
Intubation
ETT | | |
Cuffed ETT: #6 /6.5 / 7 / 8 (in theatre) | Wire Reinforced ETT (Bay 2) | RAE (Nasal/ Oral) (Bay 2) |
Cuffed ETT: #5/ 5.5 (Paed Trolley) | Micro-cuff (Paed Trolley) | Non-Cuff (Paed Trolley/ Bay 2) |
Cuffed ETT: #7.5/8.5/9 (DIT) | ML tube #4/ 5/ 6 (DIT/ Bay 2) | Bronchocath (Double lumen) (Bay 2) |
Endobronchial blocker (Arndt/Coopdech) (Bay 2) | Cooks exchange catheter (DIT) | Aintree catheter (DIT) |
LMA | | |
Classic (Bay 2) | Proseal (Bay 2) | Supreme (Bay 2) |
Igel (#3,4,5 in theatre /others: bay 2) | Tuoren (Bay 2) | |
Equipment | | |
Glidescope (Lopro T2/ MAC T3/ T4/ LoPro T3/ Lopro T4) (Bay 2) | CMAC Videostylet (Bay 2) | |
Optiflow (Bay 2) | | |
Bronchoscopy | | |
Disposable: | Ambu (Holding DIT) | Glidescope (Bay 2) |
Reusable: | Olympus 4.9mm ( Scope-store) | CMAC 5.5 (Scope-store) 4.0 (Bay 2) |
Paed Trolley: Bay B DIT: Holding and SC
SA/EA & CSE/RA
SA | | |
SA trolley (All Bay) | Long Spinal needle (Bay B) | |
| | |
EA & CSE | | |
NR fit EA & CSE set (NR fit trolley at Bay A & F) | Non NR CSE set (Bay B) | Non NR extra long CSE set (Bay B) |
Non NR EA set (Bay C Spinal trolley) | | |
RA | | |
RA box at ALL BAY (Except Bay D) | Continuous Never Block Set (Bay B) | Nerve stimulator (RA box of each bay) |
Machine/ Equipment
USG | | |
LOGIQ Totus (Bay B) | Samsung V5 (Bay C) | Venue Go (Bay E) |
GE LOGIQ e (Bay F) | | |
Infusion Device | | |
PK Pump (Bay A & F) | Syringe pump (All bay) | Blood Warmer (All Bay) -high flow set (Bay C) |
Emergency Equipment | | |
E-Trolley (SC/ RR) | LUCAS (RR) | EMMA (LUCAS trolley at RR) |
MTP trolley (SC outside OT6) | DIT (Holding/ SC) | |
三寳: H’stix (RR) | I-stat (RR) | Haemocue (all Bay & RR) |
Others | | |
BIS (Bay 2 & Attached on Atlan and Zeus) | 12-Lead ECG (RR) | Lidco monitor (Bay 2) |
Maximo (Bay C, E & RR) -with Hb function @RR | Optiflow (Bay 2) | Paed mattress (RR) |
SCD (All Bay) | TOF (All theatre & Bay 2) | Troop pillow (Bay D) |
Warming mattress (Extra at bay 2) | | |