1 of 8

Fan Regulator Circuit ( AC Load Control Using Triac & Diac ) ( Light Dimmer )

2 of 8

Circuit Description & Working

  1. The fan regulator circuit using TRIAC – DIAC is shown in the figure.
  2. The TRIAC and DIAC is bi – directional therefore they are used for alternating circuit.
  3. The RL is load resistance / lamp or two terminal of single phase winding.

3 of 8

4 of 8

  • The charging of capacitor is done through L – RL – R – C – N path.
  • When voltage across capacitor becomes equal to break over voltage of the DIAC, the DIAC turns on.
  • As soon as the DIAC turns on, the discharging of capacitor is done through C – DIAC – G – MT1 – C path. Now the gate terminal of TRIAC gets signal and TRIAC turns on.

5 of 8

  • The load resistance complete its path through L – RL – MT1 – MT2 – N.
  • The charging rate of the capacitor is depends upon the variable resistance R. The firing angle of the TRIAC depends upon variable resistance R.
  • The charging rate of the capacitor is less for higher value of resistance resulting firing angle of TRIAC increases and voltage across load reduces.
  • Similarly the load gets higher voltage for low value of resistance due to less firing angle.

6 of 8

7 of 8

Role of Variable Resistor R

  • High variable resistance – Firing angle increases – Low voltage across load
  • Low variable resistance – Firing angle decreases – High voltage across load

8 of 8

Thank You