BP701T
INSTRUMENTAL METHODS OF ANALYSIS
Unit – III
Introduction to chromatography
BP701T INSTRUMENTAL METHODS OF ANALYSIS 45 Hours
Scope:
This subject deals with the application of instrumental methods in qualitative and quantitative analysis of drugs. This subject is designed to impart a fundamental knowledge on the principles and instrumentation of spectroscopic and chromatographic techniques. This also emphasizes on theoretical and practical knowledge on modern analytical instruments that are used for drug testing.
Objectives:
Upon completion of the course the student shall be able to
THIN LAYER CHROMATOGRAPHY
Principle
Salt formation > coordination > H-bonding >
dipole-dipole > van der Waals
Polarity decreases
More Polar
Less Polar
OH
OH
OH
OH
OH
OH
OH
Mobile
phase
analytes
Silica Gel
analytes
More Polar
Less Polar
Adsorbs stronger and separate very slowly
Adsorbs weakly and separate very fast
Sample to be applied on this area
Adsorption of Solutes
The adsorption strength of compounds increases with increasing polarity of functional groups, as shown below:
-CH=CH2, -X, -OR, -CHO, -CO2R, -NR2, -NH2, -OH, -CONR2, -CO2H.
(weakly adsorbed) (strongly adsorbed)
(nonpolar) (more polar)
Elution Strength of Mobile Phase (e)
Elution strength is generally considered to be equivalent to polarity. A solvents elution strength depends on Intermolecular Forces between the solvent and the analytes and between the solvent and the stationary phase.
A more polar (or more strongly eluting solvent) will move all of the analytes to a greater extent, than a less polar, weakly elution solvent.
For example, the elution strength of hexane is very low; e = 0.01.
the elution strength of ethyl acetate is higher; e = 0.45
the elution strength of ethanol is even higher; e = 0.68
Thin Layer Chromatography - Calculation of Rf’s
The Rf Value
. distance traveled by substance . �distance traveled by solvent front
THIN LAYER CHROMATOGRAPHY
Calculation of Rf’s
The Rf is defined as the distance the center of the spot moved divided by the distance the solvent front moved (both measured from the origin)
Materials used in TLC�
Materials used in TLC
Glass Plate
Hooper
A device for applying the adsorbent layer
Developing chamber
Mobile phase
Stationery phase�
Stationery phase | Description | Application |
Silica gel G | Silica gel with average particle size 15µm containing ca 13% calcium sulfate binding agent | Used in wide range pharmacopoeial test |
Silica gel G254 | Silica gel G with fluorescence added | Same application with Silica gel G where visualization is to be carried out under UV light. |
Alumina (Al2O3) | surface area of about 200 m/g and a pore size of about 60 Å | Basic and neutral compounds, Terpenes, Alkaloids, Steroids, Aliphatic compounds, and Aromatic compounds |
Cellulose | Cellulose powder of less than 30µm particle size. | Identification of tetracycline's |
MOBILE PHASE
MOBILE PHASE
SOLVENT | POLARITY INDEX |
Hexane | 0 |
Butanol | 3.9 |
Chloroform | 4.1 |
Methanol | 5.1 |
Ethanol | 5.1 |
Acetonitrile | 5.8 |
Air | 9.0 |
Water | |
TLC plate preparation
How to perform TLC?
TLC Plate Preparation
Methods used to apply adsorbent
Spreading
Spraying
Dipping plate in slurry
TLC Plate Preparation
Materials used in TLC
Glass Plate
Spreading the slurry by Hooper
Developing chamber
Mobile phase
Activation of plate
Glass Plate
Drawing a Line and circle to apply the sample
Glass Plate
Circle to apply sample
Developing chamber
Mobile phase
Materials used in TLC
Glass Plate
Circle to apply sample
Developing chamber
Mobile phase
Methods of Plate Development
Application of sample and development of Chromatogram by Ascending way
High
Polar
Less
Polar
Development of Chromatogram by Descending way
High
Polar
Less
Polar
Development of chromatogram by descending way
Mobile Phase
Two dimensional chromatography
Solvent front
A
C
B
Solvent
A
B
C
AB
is
immersed in mobile phase
AC
is
immersed in mobile phase
X
X
Sample
Physical Methods:
Ultraviolet Light—some organic compounds illuminate or fluoresce under short-wave UV light:
TLC Visualization Methods
Chemical methods
Iodine Vapor—forms brown/ yellow complexes with organic compounds
Fluorescent Indicators—compounds fluoresce when placed under UV light
Silver Nitrate Spray (for Alkyl Halides)—dark spots form upon exposure to light
Sulfuric Acid Spray + Heat—permanent charred spots are produced
Iodine Vapor—forms brown/ yellow complexes with organic compounds
Fluorescent Indicators—compounds fluoresce when placed under UV light
Silver Nitrate Spray (for Alkyl Halides)—dark spots form upon exposure to light
Sulfuric Acid Spray + Heat—permanent charred spots are produced
Applications of TLC
Quantitative analysis
The size of the spot increases with the amount. Square root of the spot area is find out from that amount of solute can be found out.
Potentiodensitometry of the plate is carried out.
Flurometry or emission Spectroscopy is also used.
Separated spot is removed by knife edge. Its dissolved in proper solvent and its amount is finding out by volumetric analysis.
Other Applications
of
TLC
TLC can is applicable in the field of medicinal preparations, pharmaceutical preparations, natural product extract and related compounds.
Assaying the radiochemical purity of radiopharmaceuticals.
Determination of the pigments in plants.
In forensic science Laboratory detection of pesticides and insectides in food, poison etc.