1 of 11

OAI 221 - STATIC

Group Members :

  • ANANT VATSA – 2019143
  • ANMOL GOYAL – 2019147
  • SAMRIDH SHAKYA – 2019201

Group Number: 5

2 of 11

Schematic

Complex

Non - Complex

3 of 11

Layout: Complex Implementation

Layout Without PP and NP Layer

4 of 11

Layout: Complex Implementation

Layout With PP and NP Layer (Area=3.4*5.8 = 19.72 sq. um.)

​

5 of 11

Complex Implementation: DRC and LVS

6 of 11

Layout: Non-Complex Implementation

Layout Without PP and NP Layer

​

7 of 11

Layout: Non-Complex Implementation

Layout With PP and NP Layer

​

8 of 11

Simulation Waveforms

Complex : Pre Layout

Complex : Post Layout

Non-Complex : Pre Layout

9 of 11

Simulation Results

Parameter

PVT(worst)

Pre Layout

Post Layout

PVT(best)

Pre Layout

Post Layout

TPLH

SS, 0.7V, -40C

4.7771E-09

4.4277E-09

FF, 1.32V, 125C

6.7062E-12

1.696E-11

TPHL

FF, 1.32V, 125C

4.3967E-09

3.935E-09

SS, 0.7V, -40C

3.3983E-11

3.6884E-11

TPD

SS, 0.7V, -40C

3.61E-09

3.3711E-09

FF, 1.32V, -40C

3.36E-11

3.64E-11

TCD

SS, 0.7V, -40C

5.161E-09

4.8588E-09

SS, 1.08V, -40C

3.37E-11

3.72E-11

LEAKAGE

FF, 1.32V, 125C

0.00000245

0.00000279

FF, 1.32V, -40C

3.4E-12

3.41E-10

DYNAMIC

FF, 1.32V, -40C

0.0000433

0.0000436

SS, 0.7V, -40C

9.73E-09

3.65E-09

STATIC

FF, 1.32V, 125C

2.214E-07

3.1812E-07

SS, 0.7V, -40C

1.4616E-12

-3.1812E-07

10 of 11

Conclusion and Analysis

  • From the above observation we can conclude that area used by the Complex implementation is lesser than that of Non-Complex implementation.
  • Complex Gate Area = 19.72 um^2
  • As the area increases the propagation time increases, thus Tpd of complex is less.
  • The leakage current is less in post-Layout simulation as compared to pre-Layout simulation.
  • Dynamic power also decreases as we go from pre to post-Layout.
  • From above conclusions we can clearly conclude that performance evidently improves in post-Layout simulations

​

11 of 11

Work Distribution

  • Anant Vatsa : Schematic, layout, pre and post layout simulation for complex implementation

​

  • Anmol Goyal : Script For Automating Various PVT Conditions, pre and post layout simulation for complex implementation

​

  • Samridh Shakya : Schematic and layout for non - complex implementation, pre and post layout simulation for complex implementation

​

​