1 of 39

How to ablate safely and completely: �Practical Consideration for Image-guided Liver Tumor Ablation

Eunji Lim, Jin Woong Kim*, Hyun Chul Kim, Sang Gook Song, Eun Ju Yoon, Jun Hyung Hong

Department of Radiology, Chosun University Hospital and Chosun Univiersity College of Medicine,

Jeonnam-Gwangju Special Metropolitan City, Republic of Korea

How to ablate safely and completely

2 of 39

I have no financial relationships to disclose.

COI Disclosure Information

How to ablate safely and completely

3 of 39

Critical Considerations for Ablation

To ablate safely

    • Thermal injury
    • Bleeding
    • Abscess
    • Tumoral seeding
    • Biliary injury

To ablate completely

    • Tumor size & location
    • Ablative margin
    • Liver function
    • Tumor biology
    • Device / Technique selection

How to ablate safely and completely

How to ablate safely and completely

4 of 39

Possible Thermal Collateral Damage

  • Treatment outcome is strongly affected by tumor location.
  • Tumors adjacent to heat-vulnerable structures such as the GI tract or bile duct are at risk of collateral thermal injury or incomplete treatment.
  • Several adjunctive techniques, including artificial ascites, can help reduce this risk.

Fig. 1. Representative examples of collateral thermal injury after RFA.

A. Delayed colon perforation. B. Stricture of the right intraheptatic bile duct. C. Fistula tract between RF ablation zone and gastric antrum.

A

B

C

How to ablate safely and completely

How to ablate safely and completely

5 of 39

Artificial Ascites (AA)

  • Hydrodissection
    • Increases the distance between the tumor and adjacent organs
  • Improves tumor visibility by creating a better sonic window

Kim JW et al, KJR, 2015;16: 1226-1239

Rhim HC et al, AJR 2008; 190:91–98

  • Useful for subdiaphragmatic tumors & prevention of thermal collateral injury

C

D

Fig. 2. Schematic concept and clinical application of artificial ascites during RF ablation.

A,B. Schematic illustrations showing that artificial ascites creates a fluid-filled space between the diaphragm and liver, improving the acoustic window for a subphrenic tumor. C,D. Artificial ascites-assisted RF ablation via the subhepatic route in a 44-year-old man. C. Photograph shows inserted angiosheath and needle electrode. D. Longitudinal US image shows the angiosheath (arrowhead) and artificial ascites (asterisk).

A

Hydrodissection

Improve

sonic window

​

B

How to ablate safely and completely

How to ablate safely and completely

6 of 39

RFA with Artificial Ascites for Hepatic Dome HCC

E

Perihepatic route

A

B

C

D

Fig. 3. RFA with artificial ascites for a hepatic dome HCC.

A. Preprocedural CT shows a small hepatic dome HCC (arrow) beneath the diaphragm. B. US image shows index tumor (arrow) more clearly after making perihepatic artificial ascites. C. US image obtained after RFA shows artificial ascites (arrow) interposed between the hyperechoic RFA zone and the diaphragm. D. Schematic illustration demonstrates artificial ascites infusion via a perihepatic route. E, F. Immediate follow-up axial and coronal CT images show complete ablation of the tumor (arrows) without diaphragmatic injury.

F

How to ablate safely and completely

How to ablate safely and completely

7 of 39

“Leverage (lifting)” Method

Fig. 4. Schematic illustrations show mechanism of leverage (lifting) method.

A. Schematic illustration depicts insufficient hydrodissection between target tumor (T) and adjacent colon (C) after artificial ascites infusion. B. Schematic illustration demonstrates caudal tilting of distal end (handle) of needle electrode by which gap between index tumor (T) and abutting colon (C) is widened.

  • Artificial ascites alone may not provide sufficient separation from adjacent organs
  • The leverage method can further widen the gap between the tumor and heat-vulnerable structures
  • Tilting the needle handle caudally moves the liver cranially

A

B

How to ablate safely and completely

How to ablate safely and completely

8 of 39

“Leverage (lifting)” Method

Fig. 5. RF ablation using leverage (lifting)

method in 73-year-old man.

A. US image depicts index tumor with mixed echogenecity (arrow) in segment 6. There is still narrow gap (arrowhead) between tumor and colon even after artificial ascites infusion. B. Arterial-phase CT shows a small arterially enhancing HCC (arrow) abutting the colon (arrowhead). C. Immediate follow-up CT shows complete ablation (asterisk) with preservation of the adjacent colon (arrowhead). D. Intraoperative US video shows widening of the gap between the RF ablation zone and the adjacent colon after applying the leverage method. E. Intraoperative photograph demonstrates manual caudal tilting of the electrode handle (arrow) to generate the leverage effect.

A

B

C

E

D

How to ablate safely and completely

How to ablate safely and completely

9 of 39

Artificial Pleural Effusion (APE)

  • Useful for US-guided ablation of subdiaphragmatic tumors
    • Provides better visualization of the entire tumor
    • Helps secure a safer targeting route

AJR 2004;183: 583-588

J Gastroenterol 2007;42:306–311

International Journal of Hyperthermia 2013;29.7: 663-670

APE

APE

A

B

C

D

Fig. 6. Artificial pleural effusion for US-guided ablation of a subdiaphragmatic tumor.

A. Preprocedural image shows a hepatic dome tumor (arrow). B. US image shows artificial pleural effusion (APE) after pleural fluid instillation. C. US image demonstrates improved visualization of the target lesion (arrow) and a safer targeting route after APE. D. Immediate follow-up CT image confirms artificial pleural effusion in the right pleural cavity.

How to ablate safely and completely

How to ablate safely and completely

10 of 39

How to Minimize Bleeding

  • Mechanical damage by electrode placement is a major cause of bleeding
  • Risk factors for bleeding
    • Coagulopathy (m/c)
      • Platelet count > 50,000/μL
      • Prothrombin time > 50% of normal
    • Subcapsular location of tumor
  • To minimize bleeding occurrence
    • Correction of coagulopathy before RFA
    • Traversing sufficient normal liver parenchyma without crossing major vessels
    • Cauterization of electrode tract during electrode withdrawal
    • Avoid deep respiration during electrode manipulation
    • Decreasing puncture number

Deep

Breathing

Fig. 7. Schematic illustration demonstrating that deep respiration during electrode insertion may cause significant liver movement, resulting in hepatic laceration along the needle path

How to ablate safely and completely

How to ablate safely and completely

11 of 39

Bleeding after RFA

Fig. 8. Hemoperitoneum from electrode tract bleeding after RFA.

A. Immediate follow-up CT shows the ablation zone (arrow), containing the treated lipiodolized HCC (asterisk), and hemoperitoneum (arrowhead). B. Lower-level CT image reveals active bleeding in the perihepatic space (arrow). C. Emergent angiography demonstrates contrast extravasation from the left hepatic artery (arrow), which was successfully controlled by transarterial embolization.

How to ablate safely and completely

How to ablate safely and completely

12 of 39

Delayed Bleeding in Patients Receiving Antithrombotic Therapy

  • According to clinical guidelines, anticoagulation may be restarted on POD 1, if hemostasis is secured, including on immediate follow-up CT
  • Careful attention is needed after resuming antithrombotic therapy

Fig. 9. Delayed bleeding after resumption

of antithrombotic therapy following RFA.

A. MRI shows hepatic metastasis (arrow) from colon cancer. B. Planning US shows a hypoechoic target lesion (arrow). C. US-guided RFA was performed. D. Immediate CT shows technical success (asterisk) without bleeding, and anticoagulation was resumed. E. Emergency CT after abdominal pain and dizziness shows intrahepatic bleeding (arrowhead). F. Angiography demonstrates active bleeding (arrowhead) from a right hepatic arterial branch, treated with embolization. G. Two-month follow-up CT shows no residual active bleeding, with the ablation zone (asterisk) and embolization coil (curved arrow).

How to ablate safely and completely

How to ablate safely and completely

13 of 39

To Minimize Bleeding from Intercostal Vessels

  • Bleeding risk with an intercostal approach
    • Posterior arc: Intercostal vessels run along just below rib
    • Anterior arc: Intercostal vessels run along both above and below rib
  • Insert the electrode through the midpoint of intercostal space
  • Do not tilt the electrode until it penetrates the peritoneum
  1. Draw a parallel line along the mid-intercostal space.
  2. Insert the needle below this parallel line.

Fig. 10. Bleeding after RFA using an intercostal approach.

A, B. Axial and coronal CT images show perihepatic bleeding (arrow) adjacent to the RFA zone (asterisk) along the intercostal puncture route.

A

B

How to ablate safely and completely

How to ablate safely and completely

14 of 39

“Bypass” Targeting

  • Large vessels or bile ducts located in front of the tumor may prevent a straight targeting route.
    • In such cases, RFA may appear technically infeasible.
  • Bypass targeting allows the electrode to avoid these obstacles and then redirect toward the tumor using the structural flexibility of the liver.

A

B

C

Fig. 11. RF ablation using bypass targeting technique in 66-year-old man.

A. Pre-ablation CT shows HCC (curved arrow) in segment 1 near the portal vein and IVC; right portal vein (arrowhead) blocks the approach path (dotted arrow). B. Intercostal US image shows hypoechoic HCC (curved arrow) between main portal vein and IVC, with the right portal vein (arrowhead) blocking the approach pathway. C. CT 5 mm below A shows a safe approach path (dotted arrow) avoiding the right portal vein. Continued on the next slide.

How to ablate safely and completely

How to ablate safely and completely

15 of 39

“Bypass” Targeting

Fig. 11. RF ablation using bypass targeting technique in 66-year-old man.

D. Electrode tip (arrowhead) successfully targeted after redirecting the trajectory cranially. E. US during RFA shows the electrode tip (arrow) in the ablation zone (asterisk). F. Immediate CT shows complete ablation (asterisk) with intact portal vein (arrowhead). G. Two-year follow-up CT shows no local tumor progression.

D

E

F

G

How to ablate safely and completely

How to ablate safely and completely

16 of 39

To Minimize Abscess after RFA

  • Risk factors
    • Preexisting biliary abnormalities prone to ascending biliary infection
      • Clonorchiasis, bilioenteric anastomosis, endoscopic papillotomy, bilioenteric fistula, external biliary drainage, & pneumobilia
    • Immunocompromised conditions, such as diabetes
  • Prevention
    • Consider prophylactic antibiotics in high-risk patient
    • Treat cholangitis before RFA

​

Fig. 12. Hepatic abscess formation after RFA in patient with clonorchiasis.

A. Preprocedural CT shows mild dilatation of the right intrahepatic bile ducts in a patient with clonorchiasis. B. Immediate follow-up CT shows the ablation zone after RFA. C. Two-week follow-up CT demonstrates hepatic abscess formation within the ablation zone (arrow).

A

B

C

How to ablate safely and completely

How to ablate safely and completely

17 of 39

To Minimize Tumoral Seeding

  • A feared complication associated with poor prognosis
  • Known risk factors
    • “Popping” of subcapsular tumor during RFA
    • Multiple punctures, Multi-tined electrode, Large-gauge electrode
    • Poor tumor differentiation
    • High AFP or PIVKA II level before RFA
  • To reduce incidence of tumoral seeding
    • Gradual RF energy escalation to avoid “popping” of tumor during RFA
      • Prevent explosion caused by excessive increases in intra-tumor pressure
    • Needle tract cauterization
    • Reduce the number of punctures and traverse as much hepatic parenchyma as possible

Fig. 13. Tumor seeding after

RFA of a subcapsular tumor.

A. Immediate follow-up CT after RFA of a subcapsular tumor shows the ablation zone (asterisk). B, C. Eight-month follow-up CT shows multiple recurrent tumors (arrows) along the ablation zone, right kidney, and peritoneum.

A

B

C

How to ablate safely and completely

How to ablate safely and completely

18 of 39

Biliary Stricture

  • A major delayed complication that may significantly impair liver function
  • Thermal damage to IHD; common (up to 17% of ablations)
    • Heat sink effect by portal vein is usually protective (Biliary radicles run adjacent to vessels)
  • Often remains clinically silent
  • Usually presents as mild upstream biliary dilatation or segmental/lobar atrophy

​

​

Before

Imm

3M

1Y

2Y

Fig. 14. Delayed biliary stricture after RFA.

A. Pre-procedural MR shows several HCCs near the intrahepatic bile ducts. B. Immediate follow-up MR shows no definite biliary dilatation. C. Three-month follow-up CT shows upstream biliary dilatation. D, E. Long-term follow-up CT demonstrates progressive posterior segment atrophy (arrow).

A

B

C

D

E

How to ablate safely and completely

How to ablate safely and completely

19 of 39

How to Avoid Biliary Stricture

  • Biliary stricture may appear 3 months or later after ablation
    • The risk depends on the distance between the tumor and the intrahepatic duct

​

  • Prevention
    • A minimal safe distance of ≥ 5 mm is important
    • RFA combined with TACE or PEI
    • Protective biliary cooling with ENBD; Questionable

EJR. 2010;73:385-90

Fig. 15. Protective biliary cooling during RFA.

A. CT angiography shows a tumor (arrow) adjacent to the biliary confluence. B. A nasobiliary drainage catheter was endoscopically inserted into the left hepatic bile duct for intraductal cooling. C. Dynamic CT obtained after RFA with bile duct cooling shows a 40 mm ablated zone (arrow). D. Follow-up CT obtained 12 months later shows no biliary complications or local tumor progression.

A

B

C

D

How to ablate safely and completely

How to ablate safely and completely

20 of 39

Limitations of Biliary Cooling: A Cautionary Case

Fig. 16. Delayed biliary dilatation after RFA

despite ENBD-based biliary cooling.

A. Preprocedural CT shows a hepatic tumor abutting the intrahepatic bile duct. B, C. Immediate follow-up axial and coronal CT images after RFA with ENBD-based biliary cooling shows complete ablation without definite biliary dilatation. D. Two-month follow-up CT shows subtle intrahepatic bile duct dilatation. E,F. Six-month follow-up axial and coronal CT images demonstrate delayed intrahepatic bile duct dilatation, suggesting biliary stricture despite biliary cooling.

A

B

C

D

F

E

How to ablate safely and completely

How to ablate safely and completely

21 of 39

How to Ablate Completely

Tumor size

Liver Function and Treatment History

Tumor Location

Biological Behavior of the Tumor

How to ablate safely and completely

How to ablate safely and completely

22 of 39

HCC size vs. Ablation zone size

Image fusion

2cm

3-5cm

Invisible, very small HCC

Small HCC

Medium-sized HCC

3cm

TACE + Ablation

No-touch RFA

≤1cm

Ablation zone

Larger Ablation zone

Largest ablation zone

Microwave

Fig. 17. Size-based approach to HCC ablation.

- US-invisible or very small HCCs (≤ 1 cm): image fusion can help identify and target the lesion accurately.

- Small HCCs (≤ 2–3 cm): conventional RFA may be sufficient, but no-touch RFA can provide a wider ablative margin.

- Medium-sized HCCs (3–5 cm): a larger ablation zone is required; microwave ablation or TACE plus ablation should be considered.

How to ablate safely and completely

How to ablate safely and completely

23 of 39

Perivascular location & Heat-sink effect

  • Heat-sink effect 🡪 incompletely treated viable tumor
    • Perfusion-mediated cooling by adjacent blood flow
    • HCCs abutting first- or second-order PV/HV branches ≥ 3 mm in diameter
    • Long-term tumor control and overall survival: surgery > RFA

​

Ablation zone

Tumor

Convection by vessel

Viable

tumor

RF electrode

Journal of Hepatology 69.1 (2018): 70-78.

A

Fig. 18. Heat-sink effect leading to incomplete ablation.

A. Schematic illustration demonstrates perfusion-mediated cooling by an adjacent vessel. B, C. Pre-procedural CT images show a central HCC (yellow arrows) abutting the middle hepatic vein (green arrows). D, E. Three-month follow-up CT images show residual viable tumor (yellow arrows) along the hepatic vein, suggesting incomplete ablation due to the heat-sink effect.

Pre

3M

B

C

D

E

How to ablate safely and completely

How to ablate safely and completely

24 of 39

Local tumor progression (LTP) after ablation

Sasaki et al. Cancer 2005;103:299-306

Ikeda, et al, Int J Oncol 2007;31:485-491

5mm ablative margin

remain untreated

Satellite nodules located > 5 mm from the main tumor may

Fig. 19. Correlation between tumor size and distance to the microsatellite.

The tumor size and the distance from the main tumor to the microsatellite are significantly correlated (P < 0.001).

  • Satellite nodules and ablative margin
    • When the main tumor is larger than 2.5 cm, satellite nodules may be located more than 5 mm away
    • These satellite nodules may remain untreated if the ablative margin is insufficient
    • Therefore, securing an ablative margin of 5 mm is essential

​

​

How to ablate safely and completely

How to ablate safely and completely

25 of 39

Ablative Margin on Immediate Follow-up Imaging

  • Nakazawa et al. - AJR 2007
    • Small HCC (<3cm)
      • An ablative margin of ≥ 5 mm was the most important factor for local control of HCC
  • Laimer et al. – Euro Radiol 2020
    • 176 HCCs (25.2 ± 14.9 mm [2–83])
      • A minimal ablative margin of ≥ 5 mm has to be achieved to consider an ablation as successful
  • An ablative margin of ≥ 10 mm is ideal
    • CVIR 2010, JVIR 2018, Cli Colorectal Cancer 2021, etc.
    • No LTP has been reported when the margin exceeds 10 mm in HCC and CRLM

​

AM ≥ 10 mm

How to ablate safely and completely

How to ablate safely and completely

26 of 39

Conventional central targeting

  • Current limitations of single-electrode central targeting
    • Limited ablation zone
    • Insufficient ablative margin
    • Technical difficulty in accurate central targeting
      • Eccentric electrode placement may leave residual viable tumor or satellite nodules

🡪 These limitations have led to advances

such as no-touch RFA or MWA

Fig. 20. Schematic illustrations comparing electrode positioning in single-electrode central targeting.

Left: Eccentric electrode placement results in an asymmetric ablation zone with insufficient margin on one side. Right: Accurate central puncture with a 17-gauge single electrode achieves a sufficient, symmetric ablative margin around the HCC.

How to ablate safely and completely

How to ablate safely and completely

27 of 39

Advances in Ablation

  • Cutting-edge RFA devices
    • Large-bore electrode
    • Cluster electrode
    • Water-perfused electrode
  • Microwave ablation

​

27

  • No-touch RFA
  • Image fusion (with CT or MRI)
  • Contrast-enhanced US

no-touch RFA

US contrast

Water-perfused

How to ablate safely and completely

How to ablate safely and completely

28 of 39

No-touch RFA of a 2.5cm Perivascular HCC

E

F

A

Fig. 21. No-touch RFA using multiple electrodes in a 66-year-old man

A. Preprocedural image shows a 2.5-cm HCC adjacent to intrahepatic vessels (arrow). B. Planning US shows the target tumor and surrounding parenchyma. C. Procedural US image shows no-touch RFA using multiple RF electrodes placed around the tumor rather than through it. D. Schematic illustration demonstrates the no-touch technique, in which electrodes are positioned outside the tumor to create a confluent ablation zone. E. Immediate follow-up CT shows complete tumor coverage with a sufficient ablation zone and adequate ablative margin. F. One-year follow-up image shows no local tumor progression.

B

C

D

How to ablate safely and completely

How to ablate safely and completely

29 of 39

MWA of a 3.2 cm HCC in S8/4

Fig. 22. MWA of a 3.2 cm HCC in segment 8/4 in a 69-year-old man.

A. Preprocedural MRI shows a 3.2-cm HCC (arrow) in segment 8/4. B. Planning US demonstrates the target tumor (arrow). C, D. US-guided microwave ablation was performed, and the hyperechoic ablation zone progressively covered the target tumor. E, F. Immediate follow-up axial and coronal CT images show complete coverage of the index tumor by the ablation zone (arrow), with tumor contraction and a sufficient ablative margin.

3.2 cm

13 min

E

A

B

C

D

F

AFP 6.7 PIVKA-II 85

Child A

How to ablate safely and completely

How to ablate safely and completely

30 of 39

MWA of a 2.3 cm HCC in S4

Fig. 23. MWA of a 2.3 cm HCC in segment 4 complicated by duodenal ulcer in a 59-year-old man.

A, B. Preprocedural MRI and planning US show a 2.3-cm HCC (arrow) in segment 4. C, F. MWA using two antennas created a large ablation zone. D. The tumor (yellow arrow) was located close to the adjacent duodenum (blue arrow). E. Endoscopy shows a duodenal ulcer, suggesting collateral thermal injury.

Duodenal ulcer

A

B

C

D

F

E

Courtesy of Dr. MW Lee

4 min ablation (2 antennas)

How to ablate safely and completely

How to ablate safely and completely

31 of 39

Liver Function and Treatment History

Good liver function

Advanced liver cirrhosis

Hepatectomy state

  • The extent of ablation should be adjusted according to liver function and treatment history
  • A larger ablation zone is preferred in patients with good liver function, whereas limited ablation or combined treatment may be needed in patients with poor liver reserve or postoperative adhesion

How to ablate safely and completely

How to ablate safely and completely

32 of 39

Tumor Location and Technical Feasibility

● Challenging locations; collateral damage risk, poor sonic window, or lack of a safe route

● Preferred locations

- Hepatic dome, around central bile duct, around heart and IVC, perivascular, caudate lobe, subcapsular tumor

Modified from Dr. MW Lee’s presentation

How to ablate safely and completely

How to ablate safely and completely

33 of 39

MWA vs no-touch RFA

Modification of ablation zone

  • Avoid collateral damage
  • Reduce the heat-sink effect

no-touch RFA with cluster electrode

MW with Single antenna

Fig. 24. Comparison of ablation zone modification between single-antenna MWA and no-touch RFA with cluster electrodes.

Single-antenna MWA creates an ablation zone centered on the antenna and requires accurate central targeting. In contrast, no-touch RFA places multiple RF electrodes around the tumor, allowing modification of the ablation zone to avoid collateral damage and reduce the heat-sink effect near vulnerable structures such as the bile duct and portal vein.

How to ablate safely and completely

How to ablate safely and completely

34 of 39

A 1.7-cm Perivascular HCC Near the Heart and IVC

E

F

A

B

IVC

Heart

C

D

IVC

Heart

Fig. 25. No-touch RFA for a 1.7-cm perivascular HCC near the heart and IVC in a 58-year-old man.

A. Preprocedural image shows a 1.7-cm HCC (arrow) located adjacent to the heart and IVC. B. Planning US shows the tumor (arrow) abutting the IVC. C. No-touch RFA was performed to create a modified ablation zone around the tumor while avoiding collateral injury to the heart and IVC. D. Immediate follow-up CT shows complete ablation with sufficient coverage of the target tumor. E, F. Follow-up images at 18 months and 3 years show no local tumor progression.

How to ablate safely and completely

How to ablate safely and completely

35 of 39

Aggressive tumor biology:�Microvascular invasion (MVI) on MRI

Lee S, et al, J Hepatol, 2017

Courtesy of Dr. MW Lee

Ann Surg. 2021;273(3):564-571

Non-smooth tumor margin (+)

Arterial peritumoral enhancement (+)

Peritumoral hypointensity on HBP (+)

🡪 Early recurrence (18 months after)

How to ablate safely and completely

How to ablate safely and completely

36 of 39

TACE + Ablation

  • Reduces heat sink effect by decreasing tumor perfusion
  • Provides a larger ablation volume and wider safety margin

​

36

Hepatology Research. 2002

🡪 Useful for medium-sized HCCs

TACE + RFA

RFA alone

C

A

D

B

Fig. 26. TACE plus RFA for a 4-cm perivascular HCC with MVI in 65-year-old woman.

A. Preprocedural images show a 4-cm perivascular HCC (yellow arrow) with peritumoral arterial enhancement, suggesting MVI (green arrow). B. DWI shows the tumor (yellow arrow) with peritumoral hyperintensity (green arrow), also suggesting MVI (green arrow). C. Combined TACE and RFA achieved a sufficient ablation zone. D. Five-year follow-up CT shows no local tumor progression.

How to ablate safely and completely

How to ablate safely and completely

37 of 39

TACE + RFA of a 5 cm HCC in S6

Fig. 27. TACE plus RFA of a 5-cm HCC in a 71-year-old man.

A, B. Preprocedural CT shows a 5-cm HCC (arrow) with peritumoral enhancement, suggesting radiologic MVI. C. Angiography shows tumor staining. D. US-guided RFA was performed after TACE for the lipiodol-marked tumor. E. Immediate follow-up CT shows complete tumor coverage by the ablation zone. F. Follow-up MRI shows no viable tumor or local tumor progression.

AFP: >2000, PIVKA-II: 30

MoRAL score >503

A

B

C

D

E

F

How to ablate safely and completely

How to ablate safely and completely

38 of 39

Risk factors

​

​

​

​

No

Other treatments:

TACE, RT, TACE+RT, etc

Location

​

​

Subphrenic

Perihilar

Periportal

Aggressive tumor biology

​

​

MVI on MRI

High tumor marker

No-touch RFA

MWA

TACE + Ablation

Modified from Dr. MW Lee’s presentation

AA, APE,�Lapa. ablation

RFA w Biliary cooling, +TACE, +PEI

Cryoablation

Conventional RFA

Yes

Poor liver function

Yes

Technical feasibility (X)

No

Size

​

​

2-3cm

3-5cm

<2cm

Planning ultrasound

How to ablate safely and completely

How to ablate safely and completely

39 of 39

Take-home Messages

  • Successful ablation is achieved only when both complete tumor destruction and complication avoidance are accomplished.
  • Safe ablation requires meticulous pre-procedural planning, a secure access route, and appropriate use of adjunctive techniques such as artificial ascites (AA) and artificial pleural effusion (APE).
  • To secure an adequate ablative margin, the optimal strategy should be selected according to tumor size and location, including no-touch RFA, microwave ablation (MWA), and combined TACE and ablation.
  • The optimal treatment strategy should be individualized by considering liver function, tumor location, and tumor biology together.

​

Recommended reading: Kim JW, et al. Ultrasound-guided percutaneous radiofrequency ablation of liver tumors: how we do it safely and completely. Korean Journal of Radiology. 2015;16(6):1226-1239.

How to ablate safely and completely

How to ablate safely and completely