euleria lab is a class IIa medical software (MDR 2017/745) that transforms rehabilitation and training into a motivating, measured and controlled practice.
euleria lab is designed according to the latest user experience techniques. By interacting with the most accurate wearable inertial sensors available on the market, with state-of-the-art dynamometers and with sensorized boards, euleria lab enables movement professionals to perform biofeedback exercises, objective assessments, and custom movement capture with their patients.
introduction
euleria health
fields of application
Post-prosthetic rehabilitation, lower and upper limb injuries,
column problems
ORTHOPEDIC
post-stroke, Parkinson's disease, multiple sclerosis, ataxia, neurodegenerative diseases
NEUROLOGIC
Return to sport after ACL reconstruction, injury prevention,
performance
SPORT
sarcopenia, balance disorders, fall prevention,
frailty management
AGING
domains of application
exercises
euleria health
With real-time visual-auditory biofeedback, the patient becomes aware of the movement and learns to perform it correctly, avoiding compensatory movements.
Clinically, biofeedback enhances neural plasticity, promoting reorganization of neural networks and restoration of motor patterns.
The exergame mode motivates the patient throughout the process, improving treatment compliance.
the biofeedback
principle
biofeedback exercises
euleria health
biofeedback exercises
The library of 350+ exercises covers all body districts and allows working on different goals: balance, strength, mobility, load transfer and functional.
The practitioner can customize each motor task to fit the needs of the individual patient, going into detail on joint range parameters, load distribution to tolerance in identifying compensatory movements.
Exercises can be combined in sequences for specific indications to simplify the integration of technology into daily practice at the center.
exercise database
euleria health
After the exercises are performed, the results are automatically processed and made available for reference at any time:
Reports can be emailed in pdf or csv format.
results and report
biofeedback exercises
assessments
euleria health
assessments
assessments
ROM: Range Of Motion
Gait
RTS: Return To Sport
Custom data collection
Balance
FRP: Fall Risk Predictor
Strength
euleria health
euleria lab enables accurate joint capacity assessments in both active and passive modes:
reporting, in addition to the detail of angular values achieved, the symmetry indices and the distance from normative data taken from the literature.
ROM: range
of motion
assessments
euleria health
Using the stabilometric platform and an inertial sensor placed on the trunk, euleria lab allows for double leg static balance assessments (Romberg open/closed eyes test) by providing:
balance
assessments
euleria health
Gait assessments (straight walk, walk with turn, and Timed Up and Go test) are performed using 2 inertial sensors placed on the instep of both feet and an algorithm developed in collaboration with Sapienza University that provides accurate estimation of:
gait
assessments
euleria health
Battery of 5 scientifically validated tests:
which provides user profiling in terms of balance-strength-mobility and a static and dynamic fall risk index based on comparison with normative data broken down by gender and age group from relevant scientific literature.
FRP: fall risk predictor
assessments
euleria health
Battery of 7 tests developed in collaboration with Dr. Fink and the University of Innsbruck to assess lower limb performance in terms of:
The assessment provides a scientifically validated indicator for return to sport after ACL reconstruction based on comparison with normative data broken down by gender and age group.
RTS: return
to sport
assessments
euleria health
assessments
The assessment of muscle strength, carried out using a dynamometer, is an essential parameter of functional movement assessment.
Euleria lab allows maximum muscle force assessments of the following areas:
strength
euleria health
The custom capture module allows custom movements in space to be recorded by selecting the number of sensors to be used and the joints or segments of interest.
The practitioner can observe angular values in different planes of space (frontal, sagittal, and horizontal) in real time.
At the end of the acquisition, a file containing all angular values recorded during the acquisition can be exported.
custom data collection
assessments
euleria health
Each assessment automatically generates a pdf report of high clinical value and at the same time easy to read for both practitioner and patient.
The report summarizes general information about the activity performed, the detail of the results recorded, and the variation from normative data taken from literature.
Practitioners can email the results and also export them in csv format if they need to work on the raw data for the purpose of, for example, clinical research.
results and report
assessments
euleria link
euleria health
components and flow
euleria link is the web management system dedicated to the professional which is shared beween all Euleria Health solutions.
It allows to:
euleria link, web management
euleria health
results
comparison
groups
Within euleria link the practitioner has the ability to automatically compare the patient's results over time and/or with other patients.
The practitioner can associate the patient with one or more groups to have a comparison of results with their reference databases.
euleria lab accessories
euleria health
euleria lab accessories
accessories
Dedicated laptop with pre-installed software and remote control
Inertial sensor and elastic band kit
Stabilometric platform with unstable support
Dynamometer for assessing
muscle strength
Proprioceptive board
(euleria lab performance)
Obstacle kit
(euleria lab performance)
scientific validation
euleria health
validazione
euleria lab has been developed and continues to evolve by making use of collaborations with renowned professionals, clinics, universities and research institutes such as the Rizzoli Movement Analysis Laboratory in Bologna, the Santa Lucia Foundation, the Bruno Kessler Foundation, the University of Chieti, the Sapienza University of Rome and the University of Innsbruck.
There are numerous scientific articles related to the validation of euleria lab technology and its clinical efficacy on different types of patients.
scientific validation
euleria health
scientific validation
VALIDATION OF THE ANGULAR MEASUREMENTS OF A NEW INERTIAL-MEASUREMENT-UNIT BASED REHABILITATION SYSTEM: COMPARISON WITH STATE-OF-THE-ART GAIT ANALYSIS
ALBERTO LEARDINI · GIADA LULLINI · SANDRO GIANNINI · LISA BERTI · MAURIZIO ORTOLANI · PAOLO CARAVAGGI
JOURNAL OF NEUROENGINEERING AND REHABILITATION 2014, 11:136
FUNCTIONAL ASSESSMENTS FOR DECISION‐MAKING REGARDING RETURN TO SPORTS FOLLOWING ACL RECONSTRUCTION. PART I: DEVELOPMENT OF A NEW TEST BATTERY
CAROLIN HILDEBRANDT · LISA MÜLLER · BARBARA ZISCH · REINHARD HUBER · CHRISTIAN FINK · CHRISTIAN RASCHNER
FUNCTIONAL ASSESSMENTS FOR DECISION‐MAKING REGARDING RETURN TO SPORTS following ACL reconstruction. Part II: clinical application of a new test battery
E. HERBST · C. HOSER · C. HILDEBRANDT · C. RASCHNER ·C. HEPPERGER · H. POINTNER · C. FINK
COMPARISON OF THE 'BACK IN ACTION' TEST BATTERY TO STANDARD HOP TEST AND isokinetic knee dynamometry in patients following anterior cruciate ligament reconstruction
JAY R. EBERT · PETER EDWARDS · JUSTINE CURRIE · ANNE SMITH · BRENDAN JOSS · TIMOTHY ACKLAND · JENS-ULRICH BUELOW · BEN HEWITT
euleria health
scientific validation
WEARABLE INERTIAL SENSORS FOR HUMAN MOVEMENT Analysis
MARCO IOSA · PIETRO PICERNO · STEFANO PAOLUCCI · GIOVANNI MORONE
EXPERT REVIEW OF MEDICAL DEVICES - DOI: 10.1080/17434440.2016.1198694
EFFECTS ON BALANCE SKILLS AND PATIENT COMPLIANCE of biofeedback training with inertial measurement units and exergaming in subacute stroke: a pilot randomized controlled trial
A. LUPO · A. M. CINNERA · A. PUCELLO · M. IOSA · P. COIRO · S. PERSONENI · F. GIMIGLIANO · G. IOLASCON · S. PAOLUCCI · G. MORONE
FUNCTIONAL NEUROLOGY 2018;33(3):131-136
ISOKINETIC EXTENSION STRENGTH IS ASSOCIATED WITH SINGLE-LEG VERTICAL JUMP Height
FELIX FISCHER · CORNELIA BLANK · TOBIAS DÜNNWALD · PETER GFÖLLER · ELMAR HERBST · CHRISTIAN HOSER · CHRISTIAN FINK
the right to move
discover more on
euleria.health