Matchless Mine Tailings
Experiment 7 Analytical Chemistry
Arielle Boucher & Ivy Goldson
Where is it from?
The Matchless Mine, Leadville CO
Research question
Is the lead concentration in the leadville mine tailings collected from the tabor mines acceptable by EPA standards?
Procedural Summary
Week 1
Week 2
Week 3
What is GFAAS and how was it used in this experiment?
Graphite Furnace Atomic Absorption Spectroscopy
GFAAS Standard Additions
Sample 2
Slope:
x-intercept:
Sample 1
Slope:
x-intercept:
GFAAS Blank
GFAAS Results
Sample 1
Concentration of lead in soil:
42.6 mg/kg
Color: yellow
Texture: fine and powdery
Sample 2
Concentration of lead in soil:
119 mg/kg
Color: grey
Texture: course and metallic
What is ICP-OES and how was it used in this experiment?
Sample 1
Concentration of lead in soil:
40.65 mg/kg
Color: yellow
Texture: fine and powdery
Sample 2
Concentration of lead in soil:
95.5 mg/kg
Color: grey
Texture: course and metallic
The samples were taken only a few inches apart, but their lead concentrations are drastically different
Limit of Detection
LOD
LOD=3*STDEV STDEV=6.402*10^-3
LOD=3*(6.402*10^-3)=1.92*10^-2 mg/L
Spike Recovery
Sample 1: 40.65 mg/kg
Sample 2: 95.5 mg/kg
Sample 1: 42.6 mg/kg
Sample 2: 119 mg/kg
ICP-OES
GFAAS
Method Comparison
Final Results
Epa standards: 1200 ppm
Our results: 42.6-119 ppm
Conclusion: The amount of lead is well within epa standards and not a hazard to Leadville residents. There is not that much lead in Leadville.
Sources
https://www.atsdr.cdc.gov/csem/leadtoxicity/safety_standards.html