1 of 15

OXYGEN �

The safe use of compressed oxygen and recent changes to our O2 cart and policy

Before Upgrade

2 of 15

When are you required to use supplemental oxygen?

  • § 91.211 Supplemental oxygen.
  • (a) General. No person may operate a civil aircraft of U.S. registry -
  • (1) At cabin pressure altitudes above 12,500 feet (MSL) up to and including 14,000 feet (MSL) unless the required minimum flight crew is provided with and uses supplemental oxygen for that part of the flight at those altitudes that is of more than 30 minutes duration;
  • (2) At cabin pressure altitudes above 14,000 feet (MSL) unless the required minimum flight crew is provided with and uses supplemental oxygen during the entire flight time at those altitudes; and
  • (3) At cabin pressure altitudes above 15,000 feet (MSL) unless each occupant of the aircraft is provided with supplemental oxygen.

​

3 of 15

Symptoms of too little oxygen (Hypoxia)�

    • Confusion
    • Euphoria
    • Distraction from your task of flying
    • Restlessness
    • Difficulty breathing – a pressure on your chest
    • Increased heart rate
    • Skin becoming blue – check fingernails

​

4 of 15

Dangers of using concentrated Oxygen

  • Explosion or fire when in contact with organic mater. NEVER use grease or oil on a compressed oxygen fitting.
  • Release of the potential energy in the compressed cylinders and lines we use.
  • Damage to cylinders in storage or when being moved or handled.
  • Deterioration of cylinders over time weakening them
  • Release of the pressure causing the cylinder to accelerate or the loose end of a flexible line to flail around.
  • High pressure gas also causes dirt to fly around and to get into an eye.

5 of 15

Dangers of using concentrated Oxygen (cont.)

  • Cylinders may not be rated for the pressures our cart can supply. Compressed gas cylinders are to be hydrostatically tested every 5 years and more frequently if they are composite materials. Dive Shops often will “hydro” test our cylinders.
  • Heat causes pressures to increase inside cylinders. Store compressed gas where they can’t get hot enough to exceed their ratings or don’t fill them to their maximum ratings. Our cart is in a shade hangar.

​

6 of 15

There are four general classes:�

​

  • Type 1 - Metal only, either seamless forged metal or seamless steel
  • Type 2 - Metal vessel, hoop wrapped with a fiber composite
  • Type 3 - Thin metal liner, wrapped with fiber
  • Type 4 - Metal-free liner from plastic, wrapped with fiber

​

7 of 15

Summary of Ideal Gas Law

  • P x V = n x R x T(°k)
  • R = gas Constant, n = number of moles of gas

​

  • When one item changes, one or both of the other two must change.
  • For example, when filling your aircraft cylinder, the temperature of the gas in your cylinder increases as the pressure increases.
  • Therefore, fill your onboard cylinder slowly so the heat diffuses as you fill it.

8 of 15

Filling the aircraft cylinder in place

9 of 15

Changes - Improvements to Oxygen Cart

  • A new, larger gauge with one scale (PSI) and more appropriate range (0-3,000 PSI)
  • Reposition the gauge to be viewed from the front not through the expanded metal mesh.
  • Replace the thermos bottle with a sealed case that is more easily opened.
  • Preplaced three lower pressure cylinders. There is only one lower pressure cylinder now (#1)

​

10 of 15

2” Old Gauge (dual scale) vs. 2.5” New Gauge (one scale)

11 of 15

New water-tight box for records, procedure, crescent wrench, pencil and Teflon tape

12 of 15

Upgraded Cart as of 4-23-2023

​

13 of 15

Summary cylinder filling procedure

  1. Remove adapter if you are going to fill your cylinder directly from the filling line.
  2. Purge the filling line for one second.
  3. Attach the filling line to your bottle or to the filling line on our glider.
  4. Test for leaks and fix any leak using the lowest pressure cylinder.
  5. Using the lowest pressure cart cylinder that is higher than your cylinder. Let the gas flow into your cylinder. Close off that cylinder and move to the next higher-pressure cylinder. Repeat till you have reached the highest-pressure tank or 1,800 psi in your tank.
  6. Close valves on the manifold, the supply cylinder and the aircraft cylinder. Record the pressures in the last cylinder.

​

14 of 15

Summary cylinder filling procedure (Continued)

7. Open the next highest cylinder to bleed the manifold pressure into it. Close the supply cylinder and record the pressure for that tank.

8. Repeat bleeding off manifold pressure into the next lowest cylinder till you have closed the lowest pressure cylinder valve.

9. Close the manifold valve and the aircraft cylinder.

10. Disconnect the aircraft cylinder from the flexible fill line. Gas will discharge from the fill line.

11. Depressurize the manifold by holding on to the end of the filling tube and opening the manifold valve slowly.

12. Reattach the adapter if it was not in use and apply the cap to the small end of the adapter.

13. Put the cloth cover over the pressure gauge, close the cart door and lock the lock.

15 of 15

What do you need to get oxygen from ASA?

  • Attend a class.
  • Training on using the oxygen cart
  • Pay for the $25 for the use of the cart and fill the cart yourself

OR

  • Pay ASA $25 for the use of oxygen and have someone who is trained fill your oxygen bottle.

​