1 of 26

�FIRE ALARM & DETECTION

INSPECTION TESTING & MAINTENANCE

​

BY

​

G.V.CHOUDHARY

​

​

2 of 26

3 of 26

FIRE ALARM & DETECTION

  • FIRE ALARM & DETECTION SYSTEM

(C0NVENTIONAL)

FIRE ALARM PANEL

​

DETECTORS

​

CABLE

​

HOOTERS

​

MANUAL CALL POINT

4 of 26

FIRE ALARM & DETECTION

  • TYPES OF DETECTORS

​

  • ISD

​

  • PSD

​

  • HEAT (FIXED TEMP.)

​

  • RATE OF RISE HEAT DETECTOR

​

5 of 26

IONISATION SMOKE DETECTOR

6 of 26

LIGHT SCATTERING SMOKE DETECTOR

7 of 26

PHOTO OBSCURTION DETECTOR

8 of 26

FIRE ALARM & DETECTION

  • TYPES OF DETECTORS

​

  • UV DETECTORS

​

  • IR DETECTORS

​

  • BEAM DETECTORS

​

  • LHS CABLE

​

​

9 of 26

FIRE ALARM & DETECTION

10 of 26

FIRE ALARM & DETECTION

  • LIMITATIONS

​

  • LIMITATIONS ON ZONE CABLE LENGTH.

​

  • LIMITATIONS ON THE NO OF DETECTORS IN ZONE.

​

  • DETECTORS OPERATED IS TO BE FIND OUT PHYSICALLY.

​

  • PANEL SIZE DEPENDS ON NO. OF ZONE.

​

​

11 of 26

FIRE ALARM & DETECTION

  • LIMITATIONS

​

  • SYSTEM CAN NOT FUNCTION FOR ANY CABLE FAULT.

​

  • BATTERY CAPACITY DEPENDS ON THE NO OF ZONES.

​

​

​

​

​

12 of 26

FIRE ALARM & DETECTION

  • MAINTENANCE & TESTING CRITERIA

​

  • FOLLOW MANUFACTURERS RECOMMONDATION.

​

  • FOLLOW GUIDE LINES MENTIONED IN IS: 2189 FOR

MAINTENANCE OF RECORDS.

​

  • ANY PROBLEM IN THE SYSTEM IS DISPLAED ON THE FIRE ALARM PANEL.

13 of 26

FIRE ALARM & DETECTION

  • HEALTHY CONDITION OF THE DETECTOR IS RED LED FLICKERING.

​

  • DUST & DIRT ACCUMULATION TO BE REMOVED.

​

  • EACH DETECTOR IS VISUALLY EXAMINED & TESTED TO INITIATE ALARM.

​

  • PREFERRED FREQUENCY OF INSPECTION IS ONCE IN THREE MONTH.

​

14 of 26

FIRE ALARM & DETECTION

  • CONDITION OF HOOTERS & MANUAL CALL POINTS TO BE CHECKED.

​

​

​

  • MANUAL CALL POINTS CAN BE TESTED DURING INSPECTION

15 of 26

FIRE ALARM & DETECTION

  • ADDRESSABLE TYPE FIRE ALARM & DETECTION SYSTEM

​

ADDRESSABLE DETECTORS

​

MONITOR

​

SOFTWARE

​

CABLING

16 of 26

FIRE ALARM & DETECTION

17 of 26

FIRE ALARM & DETECTION

18 of 26

FIRE ALARM & DETECTION

  • ADVANTAGES OF THE ADDRESSABLE DETECTION SYSTEM

REDUCED CABLING.

​

MORE NOS OF DETECTORS TO ONE ZONE.

​

​

PINPOINT EXACT LOCATION OF FIRE

​

​

​

19 of 26

FIRE ALARM & DETECTION

  • SYTEM CAN RUN IN CASE OF POWER FAILURE ON BATTERY.

​

  • REQUIRED SIZE OF BATTERY IS SMALL

  • SYSTEM CAN RUN IF ANY CABLE BREAKS.

​

​

​

20 of 26

FIRE ALARM & DETECTION

  • MAINTENANCE & TESTING CRITERIA

​

  • FOLLOW MANUFACTURERS RECOMMONDATION.

​

  • PROGRAMMING IS DONE SO AS TO MAKE SYSTEM USERS FRIENDLY.

​

  • MONITORING OF THE SYSTEM IS DONE THROUGH SOFT WARE / PROGRAMMING

​

21 of 26

HALON ALTERNATIVE

22 of 26

FM 200 SYSTEM

23 of 26

FM 200 SYSTEM

  • FM-200 Removes Heat Energy Not Oxygen
  • Effective on Class A, B, and C fires, FM-200 extinguishes fires quickly through a combination of chemical interaction and physical heat removaL It does not smother flames by removing oxygen. FM-200 removes heat energy from fire, not oxygen from the environment. FM-200 absorbs heat from the flame zone and interrupts the chemical chain
  • reaction of the combustion process.

24 of 26

FM 200 SYSTEM

25 of 26

FM 200 SYSTEM

​

  • Storing FM-200 in cylinders as a liquid saves substantial storage space.

​

  • In addition, most FM-200 systems require less than 7% concentration to quickly extinguish a fire.

26 of 26

​

​