�FIRE ALARM & DETECTION

INSPECTION TESTING & MAINTENANCE

BY

G.V.CHOUDHARY

2 of 26

3 of 26

FIRE ALARM & DETECTION

  • FIRE ALARM & DETECTION SYSTEM

(C0NVENTIONAL)

FIRE ALARM PANEL

DETECTORS

CABLE

HOOTERS

MANUAL CALL POINT

4 of 26

FIRE ALARM & DETECTION

  • TYPES OF DETECTORS

  • ISD

  • PSD

  • HEAT (FIXED TEMP.)

  • RATE OF RISE HEAT DETECTOR

5 of 26

IONISATION SMOKE DETECTOR

6 of 26

LIGHT SCATTERING SMOKE DETECTOR

7 of 26

PHOTO OBSCURTION DETECTOR

8 of 26

FIRE ALARM & DETECTION

  • TYPES OF DETECTORS

  • UV DETECTORS

  • IR DETECTORS

  • BEAM DETECTORS

  • LHS CABLE

9 of 26

FIRE ALARM & DETECTION

10 of 26

FIRE ALARM & DETECTION

  • LIMITATIONS

  • LIMITATIONS ON ZONE CABLE LENGTH.

  • LIMITATIONS ON THE NO OF DETECTORS IN ZONE.

  • DETECTORS OPERATED IS TO BE FIND OUT PHYSICALLY.

  • PANEL SIZE DEPENDS ON NO. OF ZONE.

11 of 26

FIRE ALARM & DETECTION

  • LIMITATIONS

  • SYSTEM CAN NOT FUNCTION FOR ANY CABLE FAULT.

  • BATTERY CAPACITY DEPENDS ON THE NO OF ZONES.

12 of 26

FIRE ALARM & DETECTION

  • MAINTENANCE & TESTING CRITERIA

  • FOLLOW MANUFACTURERS RECOMMONDATION.

  • FOLLOW GUIDE LINES MENTIONED IN IS: 2189 FOR

MAINTENANCE OF RECORDS.

  • ANY PROBLEM IN THE SYSTEM IS DISPLAED ON THE FIRE ALARM PANEL.

13 of 26

FIRE ALARM & DETECTION

  • HEALTHY CONDITION OF THE DETECTOR IS RED LED FLICKERING.

  • DUST & DIRT ACCUMULATION TO BE REMOVED.

  • EACH DETECTOR IS VISUALLY EXAMINED & TESTED TO INITIATE ALARM.

  • PREFERRED FREQUENCY OF INSPECTION IS ONCE IN THREE MONTH.

14 of 26

FIRE ALARM & DETECTION

  • CONDITION OF HOOTERS & MANUAL CALL POINTS TO BE CHECKED.

  • MANUAL CALL POINTS CAN BE TESTED DURING INSPECTION

15 of 26

FIRE ALARM & DETECTION

  • ADDRESSABLE TYPE FIRE ALARM & DETECTION SYSTEM

ADDRESSABLE DETECTORS

MONITOR

SOFTWARE

CABLING

16 of 26

FIRE ALARM & DETECTION

17 of 26

FIRE ALARM & DETECTION

18 of 26

FIRE ALARM & DETECTION

  • ADVANTAGES OF THE ADDRESSABLE DETECTION SYSTEM

REDUCED CABLING.

MORE NOS OF DETECTORS TO ONE ZONE.

PINPOINT EXACT LOCATION OF FIRE

19 of 26

FIRE ALARM & DETECTION

  • SYTEM CAN RUN IN CASE OF POWER FAILURE ON BATTERY.

  • REQUIRED SIZE OF BATTERY IS SMALL

  • SYSTEM CAN RUN IF ANY CABLE BREAKS.

20 of 26

FIRE ALARM & DETECTION

  • MAINTENANCE & TESTING CRITERIA

  • FOLLOW MANUFACTURERS RECOMMONDATION.

  • PROGRAMMING IS DONE SO AS TO MAKE SYSTEM USERS FRIENDLY.

  • MONITORING OF THE SYSTEM IS DONE THROUGH SOFT WARE / PROGRAMMING

21 of 26

HALON ALTERNATIVE

22 of 26

FM 200 SYSTEM

23 of 26

FM 200 SYSTEM

  • FM-200 Removes Heat Energy Not Oxygen
  • Effective on Class A, B, and C fires, FM-200 extinguishes fires quickly through a combination of chemical interaction and physical heat removaL It does not smother flames by removing oxygen. FM-200 removes heat energy from fire, not oxygen from the environment. FM-200 absorbs heat from the flame zone and interrupts the chemical chain
  • reaction of the combustion process.

24 of 26

FM 200 SYSTEM

25 of 26

FM 200 SYSTEM

  • Storing FM-200 in cylinders as a liquid saves substantial storage space.

  • In addition, most FM-200 systems require less than 7% concentration to quickly extinguish a fire.

26 of 26