1 of 22

The use of variable frequency drives Triol to solve technical problems of energy saving, elimination of leaks and dry runs for PUMPS AND PUMPING UNITS

November, 2021

2 of 22

Speakers

Nikolay Onischenko

Sales Support Engineer

Additional contact information:

Maksym Pipich

Business development manger

Vitaliy Smyrnov

Key account manager

3 of 22

Triol - full-cycle manufacturer

Engineering and development

Production of electronics units

Manufacture of semi-finished products

Assembly, setup and testing

4 of 22

The main partners distributing our equipment and our solutions on the market:

Triol - we are trusted!

5 of 22

Triol – 28 years of experience in developing, manufacturing and servicing in demand products��Triol – complete production cycle from metalworking to electronics manufacturing��Triol More than 1200 successfully completed implementation projects; more than 50,000 units of equipment implemented at facilities in Ukraine, Russia, Kazakhstan, Romania, Azerbaijan, Argentina, Egypt, Kuwait, USA, Venezuela, Colombia and other countries.��Triol – Top 10 Power Electronics Manufacture 2021�����

Triol - we are trusted!

6 of 22

AGENDA

Challenges and solutions of the multi pump configuration

- System efficiency. Optimal distribution of the flow between the pumps

- Pumps components lifetime. Optimal distribution of the flow between the pumps

- Low-cost solution for multi pump configuration

PID Control challenges.

- intellectual energy consumption analysis

- Operation by Q/H characteristic.

- Pressure compensation

Pumping system emergency protection.

- Dry run.

- Tube leak protection.

- Pump fill

7 of 22

Triol integrated solutions

All the mentioned challenges can be resolved by automation tools.

Triol integrates it's into the VFD to provide the ready solution package all-in-one

Let’s see how it works!

8 of 22

Challenges and solutions of the multi pump configuration

The flow variation in water distribution system has a wide range.

Using the multi pump system without frequency control of all pumps always leads to asymmetric distribution of the flow between the pumps.

If flow demand is not matched with the number of rated flows of the pumps one or more pump will operate far from Best Efficiency Point (BEP)

9 of 22

Challenges and solutions of the multi pump configuration. System efficiency

Pump that operates with 30-40% load factor can have 40-50% efficiency

10 of 22

Challenges and solutions of the multi pump configuration. Pumps components lifetime

Operation far from the BEP can multiply a maintenance cost up to 10 times

11 of 22

Triol Solution for multi pump configuration

Triol multi-pump master-follower algorithm

User enters the pumps curves to the master drives

Master drive receives the pressure or flow feedback from the sensor and distribute the flow between the pumps to achieve the operation point  as close as possible to the BEP

12 of 22

Benefits of Triol Solution for multi pump configuration

Triol Multi pump master-follower algorithm provides operation in range 75-115 % of the BEP

For particular pump it allows increase

  • Lifetime of bearing seals, casing and impeller up to 5 times

  • Efficiency of particular pump operations up to 50%

  • Avoid hydraulic surges that damage the pipes and valves

  • Avoid electric surges

13 of 22

Low-cost solutions for multi pump configuration

For some customers the main factor in solutions choice it the project overall costs even if more complex solution provides better efficiency and faster payback

Solution one: VFD with cascade controller with direct start

Advantage – low equipment cost (40% less than master follower)

Disadvantage – lower efficiency, higher maintenance cost, electric surges

Solution two: VFD with cascade controller with soft start

No surges

75 % equipment cost less than less than master follower but with lower efficiency and higher maintenance cost

14 of 22

PID Control challenges. Intellectual energy consumption analysis function*

To adjust the system properly – engineer should know the instant system efficiency

Minimal possible power can be calculated with the parameter that VFD takes from sensors or recalculated from performance curves

Real consumed power can be measured by VFD directly

Intellectual energy consumption analysis function of AT24 VFD can show

How much kW*h you need for pump 1 m3 in properly adjusted system

AND

How much energy you really spent in any time of the day

* unique feature of Triol

15 of 22

PID Control challenges. Operation by Q/H characteristic

VFD parameters such as RPM or Amps are not friendly to the hydraulic engineer and not give the key information about the pump performance

AT24 UC builds the actual Q/H characteristics and show the actual working point in real time

16 of 22

PID Control challenges. Pressure compensation

If the pressure feedback sensor is installed far from the pump discharge, there is an additional integral error that lower the PID operation quality.

Triol AT24-UC provides the pressure compensation algorithm that allows to make easy PID adjustments and increase the control performance.

17 of 22

Pumping system emergency protection.       

Dry running and closed valve operation

Dry running, or running against a closed

valve, can cause enormous heat buildup

in the pump, seizure of parts, and, in a

worst‑case scenario, lead to an explosion.

VFD operates with enough parameters to detect incorrect operation and protect the equipment.

Triol AT24 has the algorithm for protection against dry running and closed valve operation

18 of 22

Pumping system emergency protection. Tube leak of protection

Knowing the performance curve, it’s always easy to detect the leaks when your loss the head and still have the flow  

Triol AT24 VFD does it

19 of 22

Pumping system emergency protection. Pump fill

If the pump running in normal mode with the empty pipe it can lead to the hydraulic surges that damage the equipment

Automatic pump filling mode integrated into the VFD allows to avoid this issues without any integrations into the SCADA

Triol AT24 provides the empty pipe filling mode

20 of 22

Your final benefits of Triol VFD integration

Features

  • Triol multi-pump control algorithms

  • PID Features

  • Emergency protections

Benefits

  • Overall system efficiency increasing up to 30 %

  • Maintenance costs decreasing up 10 times for particular components

  • Friendly parametrization for hydraulics engineers

  • No PLC. Everything you need – in the VFD

  • System is protected from destructive failures

21 of 22

AK06 – Ready solution for submersible and horizontal pumps

  • Outdoor installation for any climatic conditions
  • Built in FPWM filter for pure sine on output
  • Easy integration of any downhole sensor
  • Dedicated for fluid production algorithms
  • Flexible operation with peripheral controls and SCADA
  • Harmonic mitigation solutions

22 of 22

Thank you for

your attention!

If you still have a question, please contact us for more details