1 of 21

Final Year Project: :��Improving performance of CMOS-MEMS by adding trenches on membrane

 STUDENT NAME:1)ER JIA LE         2)STEVEN YANG

PROFESSOR:MING-HUANG LI

�

1

2 of 21

CMUT Working Principle

  • Function: To receive and emit ultrasonic signals by adjusting the gap between capacitors.

​

  • Emission Principle: Electrical signal → Ultrasonic signal. 

By applying a small AC voltage signal, with a DC bias on the thin film structure, static electricity is generated, causing deformation and vibration of the thin film structure to produce ultrasonic waves.

  • Reception Principle: Ultrasonic signal → Electrical signal. 

When the pressure-induced displacement of the thin film structure occurs due to sound waves, the capacitance value changes. The resulting motion current can be processed through the circuit to obtain a sensing 

​

​

2

 

3 of 21

Applications:Ultrasonic Probe

Ultrasound probes commonly used for medical diagnosis have frequency distributions approximately as follows:

​

3.5 MHz: General abdominal imaging, obstetrics and gynecology

5.0 MHz: Vascular surgery, breast surgery, obstetrics

7.5 MHz: Breast imaging, thyroid imaging

�

​

​

Research aim :design a resonant frequency within the range of 1-10 MHz while enhancing the output pressure during CMUT transmission.

​

3

 

4 of 21

Device design:Trenches design on membrane

  • Principle: Reduce effective thickness → Decrease structural rigidity → Enable greater displacement at the thin film edges → Enhance output pressure.

4

 

The flexural rigidity of a plate:

參考:�Improving the Performance of Capacitive Micromachined Ultrasound Transducers using Modified Membrane and Support Structures

h:effective thickness

5 of 21

Structural design:

5

Conventional

2trenches

​

​

4 trenches

​

6 of 21

Process Flow:

6

Metal

Via

SiO2

7 of 21

conventional

7

Max-disp:0.1174μm

​

​

Min.disp:0.0464 μm

​

8 of 21

2 trenches with 3μm

8

Max-disp:0.0562 μm

​

Min.disp:0.1456 μm

​

​

9 of 21

4 trenches with 3μm

9

Max-disp:0.1888 μm

​

Min.disp:0.0778 μm

​

​

​

10 of 21

COMSOL simulation result

10

Type

Min. displacement

[um]

Max displacement

[um]

​

Improvement of min

Improvement of max

Conventional

0.046

0.117

-

-

2 trenches with 3μm

0.056

0.146

21.12%

24.02%

2 trenches with 5μm

0.057

0.149

22.84%

27.17%

4 trenches with 3μm

0.078

0.189

 

72.89%

64.17%

4 trenches with 5μm

0.083

0.201

78.88%

71.04%

11 of 21

Important parameters affecting displacement

Trenches Position :Trenches positioned at the edges maximize the reduction in rigidity.

​

Number of Trenches :The greater the number of trenches, the larger the displacement at the thin film edges, simultaneously reducing the resonance frequency.

​

Trenches Width :As the width of the trenches approaches the center of the thin film, the displacement at the center of the thin film also increases.

11

12 of 21

Measure in vacuum(Network Analyzer)

12

Conventional

Simulation frequency: 7.61MHz

Actual frequency:6.30MHz

2trenches

Simulation frequency:6.56MHz

Actual frequency:5.32MHz

​

​

4 trenches

Simulation frequency:5.63MHz

Actual frequency:4.72MHz

​

 

 

13 of 21

13

Conventional

2 trenches

type

Frequency(MHz)

Bandwidth(kHz)

Q

loss

Conventional

​

6.30

25.533

267.89

-62.29

2trenches

​

5.32

8.36

635.98

-49.626

4 trenches

​

4.72

20.51

230.04

-59.464

4 trenches

14 of 21

Ultrasonic probe  measurement:

1)The component is immersed in water, and a sinusoidal voltage is applied to the component.

​

2)Ultrasonic probes are used to measure the output voltage in water at different distances from the component.

​

3)The output voltage is converted into output pressure.

​

  • 4)Finally, the component's surface output pressure is determined using regression analysis and interpolation.

​

​

​

14

15 of 21

Measurement Data:

15

2.51MHz

BW=0.23MHz

2.10MHz

BW=0.23MHz

conventional

4 Trenches

16 of 21

Output Pressure vs. Distance :

16

17 of 21

Result Comparison

17

Parameter

Device type

Bias voltage

Frequency

Electrode to Resonator Gap

Array number

Distance

Output pressure

Square shape(This work)

conventional

DC: 50V

AC: 10V

2.51MHz

0.64μm

100

1mm

 5.4kPa

Square shape(This work)

​

4 Trench

design

DC: 50V

AC: 10V

2.10MHz

0.64μm

100

1mm

 8.04kpa

NTHU[1]

Dual

eletrode

DC:170V

Impulse:170V

1MHz

0.64μm

72

10mm

12.72kpa

NTHU[1]

Single

electrode

DC:200V

Impulse:170V

2MHz

0.64μm

72

10mm

43.9kpa

GT[3]

Single

electrode

DC:100V

Impulse:100V

3.5MHz

0.6μm

33

15mm

2.24kpa

18 of 21

Conclusion:

  1. Through trench design with the same electrode area, film thickness, and capacitor gap,the performance of output pressure has increased by 49 %

​

  • The trench design on CMUT enhances the output pressure while reducing resonance frequency.

​

  • Large arrays can strengthen signals but also pose challenges in measurement.

​

​

18

19 of 21

未來發展

  1. 透過搭配界面電路,減少整列數量與其他論文中的設計做比較

​

  • 再次進行2 trenches的超聲波量測作為比較驗證模擬

​

  • 下線不同凹槽寬度的設計進行比較驗證模擬

​

​

19

20 of 21

感測原理:

  •  

20

21 of 21

共振頻率誤差原因:

21

1)晶圓廠製程後的薄膜實際厚度誤差:±10%的厚度

2)後製程中蝕刻可能有undercut或overetching的可能

3)模擬中的設定材料參數上與現實存在一定誤差

​

COMSOL中 Young‘s modulus設定:silicon:70 GPa Al:70 GPa

�

​