1 of 11

CD-RCM: Generalizable Continuous-Depth Novel View Synthesis for Reflectance Confocal Microscopy

1

Authors: Tooba Imtiaz1, Milind Rajadhyaksha2, Kivanc Kose*,2, and Jennifer Dy*,1

2026

1

2

Presenter: Tooba Imtiaz

2 of 11

Reflectance Confocal Microscopy (RCM)

2

en-face @ surface

? unknown depths

en-face @ depth 3μm

en-face @ depth 6μm

en-face @ depth 200μm

z

200μm

Sparse, anisotropic z-stack

? unknown depths

? unknown depths

z

non-invasive, in vivo imaging

0.5μm

3 of 11

Reflectance Confocal Microscopy (RCM)

3

z

0.5μm

Sagittal View

Coronal View

Angular cross-section

Cross-Sectional Views

z-stack

4 of 11

Reflectance Confocal Microscopy (RCM)

4

z

0.5μm

z-stack

Sagittal View

Coronal View

Angular cross-section

Cross-Sectional Views

Clinician must scroll through 50–65 slices;�mentally reconstruct 3D structure

3D tissue architecture is precomputed and presented; no mental reconstruction needed!

Matches vertical section geometry of H&E histopathology; clinicians read it with existing training

En-face geometry has no equivalent in histopathology; clinicians must translate b/w imaging modes

Structural inconsistencies across depth (registration errors, acquisition noise) immediately visible as discontinuities

Motion artifacts and low-signal slices appear as individual bad frames; can be missed/misinterpreted

DEJ, the primary diagnostic landmark for melanoma staging, renders as an identifiable transition

DEJ appears as gradual textural shift across many slices; no clear boundary visible in any one frame

5 of 11

Comparison of Imaging Paradigms

5

  • Multiple posed views with geometric parallax
  • Multiple angle transmission projections; 3D structure from X-ray attenuation
  • Axial optical sectioning; en face imaging of discrete depths

6 of 11

Modeling RCM Acquisition as Axial Translation

6

Camera Pose

cᵢ ← (cᵢ − c̄) / c∞

Shared normalized coordinate system preserves relative depth.

Camera intrinsics K

- Identity rotation: R = I3

- Pure z-translation:

​

​

- World-to-camera transform:

​

🡪 Camera pose (c2w):

constant axial step-size

slice index

  • Mean camera center:

​

  • Max. absolute translation:

​

🡪 Standardized poses:

Stack Canonicalization

  • Focal length proportional to image resolution:

​

​

and

​

constant scaling factor

7 of 11

Method

7

Self-attention

Patchify

Transformer Block (x 24)

Input I2 �& Plücker Rays

Predicted Target�Ît

Input I1 �& Plücker Rays

Ground Truth�It

xk

xk+1

yl

ŷl

MLP

Target Plücker Rays

RCM Probe

Z

Skin section (in vivo)

Linear

Unpatchify

Linear

LoRA-adapted Dinov3, trained on dermatology images

8 of 11

Method

8

z

INPUT

3 sparse slices

CD-RCM

OUTPUT

predicted targets

z

INPUT

3 consecutive slices

CD-RCM

continuous depth interpolation

Training Time

Inference Time

OUTPUT

9 of 11

Results

9

Qualitative comparison of NDS methods. CD-RCM best preserves fine cellular structures and depth-dependent morphology, producing predictions closest to GT.

Quantitative comparison. CD-RCM outperforms classical interpolation and learned baselines across photometric (PSNR, SSIM) and perceptual (LPIPS, LSPF) metrics

Qualitative comparison of NDS methods. CD-RCM best preserves fine cellular structures and depth-dependent morphology, producing predictions closest to GT.

10 of 11

CD-RCM – Results

10

11 of 11

CD-RCM: Generalizable Continuous-Depth Novel View Synthesis for Reflectance Confocal Microscopy

11

2026