BARRIER FENCE�
www.barrierfence.ca
1 of 5
2” FENCE SYSTEM
WIND TESTING
APRIL, 2022�
WIND TESTING
www.barrierfence.ca
Tolerance to harsh weather conditions, including wind is a frequently discussed topic around all products exposed to weather. Barrier Fence conducts tests to ensure our products meet our customer expectations. While no guarantee can be made given a variety of weather factors, install methods, soil conditions etc. This document contains our research and recommendations on building a Barrier Fence.
TESTING METHODS
INSTALLATION
The specimen was installed into a 2x10 pine buck with a 1/4" perimeter joint. The vertical posts were restrained 1" below the bottom edge of the fence on both sides using 3" x 3" x 3/16" steel angles attached to the buck using 1/4 x 1-1/2" lag screws.
2 of 5
2” WIND TESTING
WIND TESTING
www.barrierfence.ca
FRAME CONSTRUCTION
The fence panels consisted of EPS bead board insulation with a steel skin. Six panels were interlocked vertically. The perimeter of the fence was captured by steel U-channels attached to the panels on the interior and exterior using #10 x 1-1/2" screws spaced 1" from ends and 30" on center at top and bottom and 1" from ends and at center of each panel at the sides. The side channels were attached to the vertical posts using 1/4-14 x 1-1/4" Teks screws. The vertical posts were 2- 1/2" x 2-1/2" x 0.095" thick steel tubes.
Uniform Proof Load per ASTM E330-14
2-mil plastic film was used to prevent air leakage during testing. It is the opinion of the test technician that this film did not influence the results of the test.
3 of 5
2” WIND TESTING
WIND TESTING
www.barrierfence.ca
Specimen #1
Applied Load:
Vertical Post Above Anchorage
Span(L):
Net Deflection:
Net Permanent Set:
Horizontal Panel Member
Span (L):
Net Deflection:
Net Permanent Set:
*The specimen passed a 44 psf load. Failure occured during a 48 psf load. The vertical posts yielded at the anchorage interface.
2080 Pa (43.5 psf)*
PASS
1905 mm (75 in)
119.4 mm (4.70 in)
16.3 mm (0.64 in)
PASS
2261 mm (89 in)
12.6 mm (0.50 in)
0.4 mm (0.02 in)
No permanent
damage
No permanent
damage
4 of 5
2” WIND TESTING
*Fence panel passed laboratory simulated wind speed testing of 210 kph.
WIND TESTING
www.barrierfence.ca
Specimen #1
Applied Load:
Vertical Post Above
Span(L):
Net Deflection:
Horizontal Panel Member
Span (L):
Net Deflection:
Uniform Design Load per ASTM E330-14
2-mil plastic film was used to prevent air leakage during testing. It is the opinion of the test technician that this film did not influence the results of the test.
1390 Pa (29.0 psf)
PASS
1905 mm (75 in)
68.1 mm (2.68 in)
PASS
2261 mm (89 in)
7.7 mm (0.31 in)
No permanent
damage
No permanent
damage
5 of 5
2” WIND TESTING