JavaScript isn't enabled in your browser, so this file can't be opened. Enable and reload.
Electrical Mcqs Quiz#03 | 2020 |
Transformer based
Sign in to Google
to save your progress.
Learn more
Two transformers operating in parallel will share the load depending upon their............?
2 points
(a) leakage reactance
(b) per unit impedance
(c) efficiencies
(d) ratings
Clear selection
If R2 is the resistance of secondary winding of the transformer and K is the transformation ratio then the equivalent secondary resistance referred to primary will be
2 points
(a) R2/VK
(b) R2IK2
(c) R22!K2
(d) R22/K
Clear selection
What will happen if the transformers working in parallel are not connected with regard to polarity?
2 points
(a) The power factor of the two trans-formers will be different from the power factor of common load
(b) Incorrect polarity will result in dead short circuit
(c) The transformers will not share load in proportion to their kVA ratings
(d) none of the above
Clear selection
In a transformer tapping are generally provided on.......
2 points
(a) primary side
(b) secondary side
(c) low voltage side
(d) high voltage side
Clear selection
The use of higher flux density in the transformer design................
2 points
(a) reduces weight per kVA
(6) reduces iron losses
(c) reduces copper losses
(d) increases part load efficiency
Clear selection
The chemical used in breather for transformer should have the quality of........
2 points
(a) Ionizing air
(b) absorbing moisture
(c) cleansing the transformer oil
(d) cooling the transformer oil.
Clear selection
The chemical used in breather as ........
2 points
(a) asbestos fiber
(b) silica sand
(c) sodium chloride
(d) silica gel
Clear selection
Which of the following does not change in a transformer ?
2 points
(a) Current
(b) Voltage
(c) Frequency
(d) All of the above
Clear selection
In a transformer the energy is conveyed from primary to secondary.
2 points
(a) through cooling coil
(b) through air
(c) by the flux
(d) none of the above
Clear selection
A transformer core is laminated to
2 points
(a) reduce hysteresis loss
(b) reduce eddy current losses
(c) reduce copper losses
(d) reduce all above losses
Clear selection
The degree of mechanical vibrations produced by the lamination of a transformer depends on.
2 points
(a) tightness of clamping
(b) gauge of laminations
(c) size of laminations
(d) all of the above
Clear selection
No-load current of a transformer has....
2 points
(a) has high magnitude and low power factor
(b) has high magnitude and high power factor
(c) has small magnitude and high power factor
(d) has small magnitude and low power factor
Clear selection
Greater the secondary leakage flux...
2 points
(a) less will be the secondary induced e.m.f.
(b) less will be the primary induced e.m.f.
(c) less will be the primary terminal voltage
(d) none of the above
Clear selection
The power transformer is a constant
2 points
(a) voltage device
(b) current device
(c) power device
(d) main flux device
Clear selection
Two transformers operating in parallel will share the load depending upon their
2 points
(a) leakage reactance
(b) per unit impedance
(c) efficiencies
(d) ratings
Clear selection
Submit
Clear form
Forms
This content is neither created nor endorsed by Google.
Report Abuse
Terms of Service
Privacy Policy
Help and feedback
Contact form owner
Help Forms improve
Report