DCARI Virtual Fire Investigation Training-Session #10 Corrugated Stainless Steel Tubing-ATF Electrical Engineer Jeremy Neagle
This recorded class is meant to be used as a guide for individuals who conduct origin and cause investigations. The link to the class is below:

https://us02web.zoom.us/rec/share/kjuHvTkmoqH8P5Z1KB284y1v-0pNXadbQu-Q4Q9HM2wkesPDo8QavpJGBRq4OUiO.xnflZjm7766tIuoS?startTime=1603386355000

Email: dcari.danecounty@gmail.com with any questions.
Sign in to Google to save your progress. Learn more
Email *
Name (First Last)
As you want it to appear on your certificate of attendance.
Your Department/Agency name ?
Phone number?
Sometimes email addresses are entered incorrectly. We will only use this to contact you if there is an issue with the certificate being bounced back. WE WILL NOT SHARE THIS WITH ANYONE OUTSIDE OF THE DCARI BOARD.
What state are you located in ?
What country are you located in ?
Clear selection
Do you investigate fires for:
Clear selection
Would you like to receive an email with all of the other virtual trainings DCARI has provided ?
Clear selection
1. The polymeric jacket of yellow CSST serves an important role in safety of the CSST installation:
7 points
Clear selection
2. Factory training for the design and installation of CSST systems may come in the form of:
7 points
Clear selection
3. Requirements for the installation of CSST systems can be found in:
7 points
Clear selection
4. According to the current edition of the National Fuel Gas Code, the minimum size bonding conductor for CSST systems is:
7 points
Clear selection
5. CSST installed in which of the following locations requires additional protection:
7 points
Clear selection
6. CSST system components are universal and can be mixed-and-matched among different manufacturers:
7 points
Clear selection
7. A leak test which provides a measurement of volumetric flow rate is:
7 points
Clear selection
8. Connecting objects together to establish electrical continuity and conductivity is known as:
7 points
Clear selection
9. According to the current edition of the National Fuel Gas Code, the maximum length of bonding conductors for CSST systems is:
7 points
Clear selection
10. Black jacketed CSST products are immune to the lightning damage concerns of yellow jacketed CSST products:
7 points
Clear selection
11. Courts have awarded settlements in CSST lawsuits to include:
7 points
Clear selection
12. CSST may be used with natural gas only:
7 points
Clear selection
13. Lightning damage to CSST systems may result in:
7 points
Clear selection
14. The thickness of metal used to fabricate CSST is about equivalent to that used in steel pipe or copper tube:
7 points
Clear selection
15. Leak testing should be conducted at system pressure, but generally no more than:
7 points
Clear selection
I have the following question for the instructor:
Comments/Feedback?
Submit
Clear form
Never submit passwords through Google Forms.
reCAPTCHA