Part66EASA Module11A.6 Electrical Power (2of 3)
The test is based on EASA Aircraft Maintenance Licence Programme
Email *
When a lead acid battery is in discharge condition the specific gravity of electrolyte will  
*
1 point
Rotating field stationary armature AC generators output is taken from
*
1 point
A dc generator will be connected to the bus bar after the reverse current cutout contact close due to
*
1 point
When using ac power on the busbar ,28 volt dc is required for battery charging ,can be achieved 
*
1 point
An APU generator can normally be used during flight as a backup supply  
*
1 point
The three voltages of a three phase generator are
*
1 point
The frequency of an ac generator is dependent on the 
*
1 point
To restore the level of electrolyte which has been lost due to normal gassing during battery charging 
*
1 point
The output of the DC generator is controlled by varying the field current
*
1 point
With a vibrating contact type voltage regulator the adjustment of generator voltage is carried out by 
*
1 point
While installing aircraft batteries the last lead to connect is
*
1 point
If a Ni- Cd aircraft battery is not required for immediate service ,it should be stored in
*
1 point
In a dc shunt generator if load is increased the voltage will
*
1 point
When checking specific gravity of the electrolyte in a battery
*
1 point
Speed of an alternator may be controlled by
*
1 point
To prevent corrosion at the terminals of a lead acid battery
*
1 point

 12 volt lead acid battery has

*
1 point
A frequency wild supply would be suitable for 
*
1 point
A generator at 30 kva , power factor 0.8 has a maximum continuous power output of
*
1 point
Method of maintaining a constant voltage output from an a/c generator under varying condition of speed and load is to vary the
*
1 point

which aircraft circuit would be most likely to use frequency wild 200 V AC

*
0 points
Vibrating contact voltage regulator sensing coil is
*
1 point

To adjust the voltage output of the ac generator while maintaining constant frequency ,it is necessary

*
1 point
The rpm of a 6 pole,400Hz alternator is 
*
1 point
In a delta winding generator fitted on turbine engine
*
1 point
Two 12 volt 25 AH batteries connected in series will produce 
*
1 point
For battery charging, the electrical supply connected to the battery must be 
*
1 point

Two similar 12 volt batteries connected in parallel will produce 

*
1 point
On a dc series generator without a voltage regulator ,if the load increases ,the generator output voltage will
*
1 point
The correct way to determine the state of charge of a nickel cadmium battery is by checking
*
1 point