Westmead Electron Microscopy - Vitrobot Training Competency
Laboratory basic safety
*Required
Sign in to Google
to save your progress.
Learn more
* Indicates required question
Email address
*
Your answer
Name
*
Your answer
The Vitrobot is in a PC2 facility. Tick all that apply.
*
1 point
Washing hands before leaving the laboratory is a requirement
Food and drink can be brought into the PC2 laboratory
Knowing what to do in an emergency is a requirement for using the laboratory
I need to have been signed off on PC2 training before using the Vitrobot
Required
The Vitrobot can be used outside normal laboratory operating hours of 8:30-17:00?
*
1 point
True
False
When using the Vitrobot, I am allowed to have a mobile phone in the PC2 lab?
*
1 point
True
False
You are in the PC2 lab and the oxygen alarm sounds indicating the oxygen level is low. Tick all that apply
*
1 point
Reset the oxygen alarm panel
Stop what I am doing and leave the PC2 lab immediately
Continue on with my experiment and hope that a staff member checks that I am ok
Check oxyegn level returns to normal before returning to the PC2 lab
Required
The Vitrobot can be used if no one else is in the Electron Microscope Facility
*
1 point
True
False
What type of water is used in the humidifier of the Vitrobot
*
1 point
Tap water
Distilled water
MilliQ water
You need to wear latex or nitrile gloves when liquifying ethane with liquid nitrogen
*
1 point
True
False
You should replace blotting paper on the Vitrobot (Tick all that apply)
*
1 point
when the blotting paper looks wrinkled
every time you blot a sample
at the start of a new Vitrobot session
when the Vitrobot tells you to change the paper
When loading the tweezers into the specimen arm of the Vitrobot, it doesn't matter what orientation they are in?
*
1 point
True
False
If there is excess liquid ethane at the end of the Vitrobot session, you
*
1 point
Dispose of it down the fumehood sink
Let the ethane evaporate in the fumehood
Decant the ethane into a labelled waste bottle
Store the ethane to use again in the next Vitrobot experiment
Before shutting down the Vitrobot, tweezers need to be removed from the plunging device
*
1 point
True
False
To call police, fire, or ambulance from inside ICPMR, I need to dial
*
1 point
0000
000
2222
911
You need to be familiar with the SOP, SWP, emergency contacts, as well as any other safety policies in place before accessing the Vitrobot?
*
1 point
True
False
If the ethane cylinder is empty, I can replace the empty cylinder with a full ethane cylinder myself?
*
1 point
True
False
Once specimens have been frozen on the Vitrobot they can be stored in liquid nitrogen and viewed on the TEM on another day
*
1 point
True
False
Before shutting down the Vitrobot you need to (Tick all that apply)
*
1 point
Remove the tweezers
Remove the liquid ethane container
Remove the blotting papers
Required
The spindle needs to be removed from the liquid nitrogen/ethane container before loading onto the Vitrobot
*
1 point
True
False