QUICK INSTALL TUHORSE SOLAR PUMP GUIDE:

1. Control board factory default setting has a wire bridge on "Com1" and "WH".

If a well sensor needs be installed, remove the wire bridge off from "Com1" and

"WH" and connect the well sensor to "Com1" and "WH". It does not matter which

colour wire is connected to “Com1” or “WH”.

2. The water sensor needs to be installed vertically standing upright. You can either

attach it to the pipe or put a weight on the sensor so that it will stand upright.

3. You should test sensors at this point to ensure that it works properly.

4. The "speed" switch factory setting is set at maximum speed. You can decrease the

head or volume by turning this motor “speed” switch down.

5. There is also a "timer" switch above the "speed" switch. The factory default

setting on the “timer switch” is 0 minutes. This timer cycle will be triggered

where the power is low, bore water is low or the tank is full. The timer is

essentially the length of the cycle before it checks the power, bore water and tank

level settings again. If the power, bore water and tank levels are at the requisite

levels, the pump will restart, however, where one of these conditions remain

unsatisfied, the timer cycle will restart.

You can set the cycle from 5 minutes to 30 minutes.

6. There are three wires coming from motor which are Black, Blue and Brown.

Please connect these three wires to the control box using these corresponding

connection points: 1-Black, 2-Blue, 3-Brown.

7. After you turn the power switch to the "solar" setting, the power LED will turn on

and then "pump" LED will also turn on. This is when the motor will start to spin.

After about 10 seconds, the "MPPT" LED will start to flash. This means the solar

pump is working in good conditions.

8. Once you have the solar pump working, please install the control box under the

panels or in shade. This is to avoid direct sunlight on the control box during the

day and prevent overheating of the control box.

9. Solar pump should not under water more than 40m. Best result is 10-30m under

water. If total head more than 40m. Please install a non return valve above pump.