10/08/2018 - Chris

Boards tested to ship to OSU

4018 - All OK

4315 - All OK

5024 - All OK

5004 - All OK

4027 - All OK

4240 - All OK

4305 - All OK

4294 - All OK

15/07/2018 - Chris

Board 6051 - All OK (tested for DBM SR1)

13/04/2018 - Chris

Board from AFP tested: 6042

31/01/2018 - Chris

Boards tested from PIT all have at least one channel with back optical power…

4236

4171

4169

4218

5018

4068

4155

5047

4232

4154

5010

4201

5008

4147

5022

4211

5009

4125

4127

5043

25/01/2018 - Chris

Boards rested for PIT:

4315 -> All OK

4240 -> All OK

22/01/2018 - Chris

Boards tested for PIT:

5024 -> Removed from SR1 setup, All OK

5023 -> All OK

5065 -> All OK

4307 -> All OK

4308 -> All OK

4309 -> All OK

4310 -> All OK

4312 -> All OK

4313 -> All OK

4314 -> All OK

18/01/2018 - Chris

Boards tested for PIT:

5021 -> Tested again after removal of object from outside VCSEL, tried to blow air and it would not remove, so used a tweezer… Ch 7 has no OP and full error counts -> Given to Didier for potential wire bond repair

5064 -> Tested again after shaving of ruff edges - All OK

5036 -> All OK

4304 -> All OK, again issues with fiber labeled VCSEL1

4305 -> All OK,

4306 -> All OK

Boards for KK:

4117 -> Broken

4004 -> was 2nd class ->  Only middle VCSEL working

4055 -> OP lower on outer VCSEL, no error counts

4042 -> OP and Errors OK… Might have an issue in fiber labeled VCSEL1 in setup… (Know we have an issue with this board, maybe VCSEL alignment?)

4112 -> OP and Errors OK

17/01/2018 - Chris

Boards prepared for the PIT:

5064 -> all great

4299 -> all great

4300 -> all great

4301 -> all great

4302 -> all great

4303 -> all great

16/01/2018 - Chris

Three D type boards to continue replacement:

4294 -> Issue with VDC channel 4… OP OK -> To be investigated

4295 -> All great

4296 -> all great

4297 -> all great

Boards extracted from PIT:

MEASUREMENTS DONE USING VCSEL 2 on outside and VCSEL 1 on middle

4256 -> No OP and full Errors on Ch 2 (Dark in picture)

4259 -> No OP and full Errors on Ch 5 (Dark in picture) Full Errors on Ch 12 (Also dark in picture) -> No OP Measurement???

4245 -> No OP and full Errors on Ch 4 & 10 (Both Dark in picture)

4247 -> No OP and full errors on Ch 3 & 5 (Both Dark in picture) Full Errors on Ch 12 (Also dark in picture) -> No OP Measurement???

4261 -> No OP and full errors on Ch 11 (Dark in picture)

5062 -> Swapped VCSEL fibers (put 2 in middle) then No OP and full errors on Ch 2 (also dark in picture)

15/01/2018 - Chris

Two B-type boards prepared for PIT replacement.

5021

5012

12/10/2018 - Chris

Test boards recommended for PIT replacement.

4085

4117

4207

4286

4290

All look good in both power and error counts.

11/01/2018 - Chris

Verify which boards are in SR1 ToothPix setup:

Pixel / counting room side

5003 (11)

5024 (10)

4265 (9)

4019 (8)

4011 (2)

4012 (3) -> Assumed

4013 (4) -> Assumed

4017 (5) -> Assumed

IBL / Clean room side:

6051 (23) -> DBM

6001 (17) -> IBL

6026 (18) -> IBL

6022 (13) -> IBL

Went through board storage to check presence of boards…

Updated: https://docs.google.com/spreadsheets/d/1ZQj8LxY1mZKpSWbUh-Ojd00JxqA506NC0cnced52YVc/edit#gid=0

10/01/2018 - Chris

History of Boards pulled out for qualification and possible PIT replacement:

4018 -> 6/4/2013: 384mA - all channels no errors, optical power OK -> 03/17/2014: scan #40435 -- all ok -> Week of 10/19/2015 Chris used for learning setup

4027 -> 6/4/2013: 380mA - all channels no errors, optical power OK -> 03/17/2014: scan #40413 -- all ok -> 16/04/2016: Optical power is okay, No error count

4036 -> 07/05/2013: 384mA, all channels no errors, optical power OK -> 08/06/2013: connected to optobox -> 1/27/2014: 384 mA, error counts test OK, optical powers OK -> 03/14/2014: scan #40364 -- all ok

4085 -> 10/01/2013: IVVDC = 383 mA, error counts test OK, optical powers are OK -> 01/31/2014: 383 mA, all ok. -> 03/18/2014: 2D-scan, scan #40550 -- all ok

4240 -> 1/27/2014: 391 mA, error counts test OK, optical power OK -> 03/17/2014: scan #40398 -- all ok

4018:

Turn on (defaults):

VVDC -> 2.47

IVVDC -> 238m

Iset (uA) -> 40.8

Ipin -> 957u

Ret Ipin 1 -> 2.23u

Ret Ipin 2 -> 619n

NTC -> 104m

All good power and errors

4018, 4027, 4036, 4085, 4240 -> All tested at 1mA Iset… all power OK and no Errors!

Set aside for PIT replacement.

06/10/2017 - Chris

Boards given for removal testing:

5040

4016

4010

4003

4054

5006

6016

22/03/2017 - Chris

6047 - Tested for ToothPixDBM… OP on VCSEL1 Bad. Physical inspection shows issues with pins on connector

6051  - OP and Error Good Installed for ToothPixDBM

15/11/2016 - Chirs

Boards used for removal practice

5006

4054

4003

6020

5040

4010

6016

4016

14/11/2016 - Chris

2026 - Tested for ToothPixIBL… OP GOOD, No Errors - Moved to ToothPixIBL

21/10/2016 - Chris

6047 - Installed in ToothPix for DBM

6022 - Installed in ToothPix for

06/09/2016 - Chris

6002 - Optical power a bit low… maybe loose fiber in setup, No Errors

6001 - Optical power is OK, No Errors - Moved to ToothPixIBL (23Sept2016)

6022 - Optical power is OK, No Errors

6000 - Fails Physical inspection. Did not test

20/08/2016 - Chris

6051 - Optical power is okay, no error count (used as control back to storage)

6003 - No optical power from VCSEL2, verified using phone camera

16/04/2016 - Chris

4013 - Optical power is okay, many DORIC errors

4018 - Optical power is okay, cannot find good region for DORIC errors (assume operator error)

4306 - Optical power is okay, cannot find good region for DORIC errors(assume operator error)

4286 - Optical power is okay, cannot find good region for DORIC errors(assume operator error)

4027 - Optical power is okay, No error count

4013 - RETEST, NO ERROR COUNT

10/29/2015 - Chris & Shane

5024 - Optical power is okay, No error count

5024 - Installed in ToothPix setup: slot 10 NOTE: sticks out because of plug in back. (Fibers not yet connected.)

10/27/2015 - Chris, Shane, Siinn

4018 - Optical power is okay, No error count

4015 - Broken DORIC fiber plug (Bent support on plug)

10/20/2015

5024 - Optical power is okay, No error count

4015 - Optical power from 0-6 is very low  (0-50), errors are crazy not good

4018 - Optical power from 0-6 is very low  (0-50), errors are crazy not good

10/19/2015 -- These tests performed by Chris not using default optical cables. Instead In1 & In2 on “black boxes” are plugged directly into optoboard. After many cleanings I suspect faulty optical cable.

4019 - Optical power is okay, No error count

4015 - Optical power from 0-6 is very low  (0-50), error not tested

5024 - Optical power is okay, No error count

4018 - Optical power from 0-6 is very low  (0-50), error not tested

10/16/2015

4012 - Optical power is okay, No error count

4017 - Optical power is okay, No error count

4011 - Optical power is okay, No error count

4013 - Optical power is okay, No error count

5003 - Optical power is okay, No error count

5024 - Optical power is okay, No error count

4265 - Optical power is okay, No error count

09/25/2015

4042 - Optical power is okay, No error count -- Chris training

07/24/2015

4005 - Optical power is okay. Error on channel 5

4011 - Optical power is okay. No error count

4012 - Optical power is okay. No error count

4013 - Optical power is okay. No error count

4015 - Optical power is okay. No error count

07/23/2015

6042 - Optical power is okay. No error count

6040 - Optical power is okay. No error count

6045 - Optical power is okay. No error count

6026 - Optical power is okay. No error count

5004 - Optical power is okay. No error count

5021 - Optical power is okay. No error count

5012 - Optical power is okay. No error count

07/17/2015

5023 - Optical power is okay. No error count

4265 - Optical power is okay. No error count

5003 - Optical power is okay. No error count

07/16/2015

5036 - Optical power is okay. No error counts

4002 - No error counts, Optical power is good only on VCSEL 2.

4002        7/16/2015 5:27:08 PM        4.676500E+2        3.760726E+2        4.173539E+2        4.239197E+2        4.060727E+2        2.464961E+2        3.724058E+2        2.880666E+3        2.933151E+3        3.020628E+3        2.725978E+3        3.345214E+3        3.762731E+3        3.458662E+3

01/15/2015

Stopping the run. The run was going fine, no error counts

Testing the optoboard 4082, taken from Bern.

4082- 415 mA, optical power OK, channel 4 has slow error count (~1 per 20 sec)

01/13/2015

The run is going fine, no error counts

01/07/2015

The run is going fine, no error counts.

12/18/2014

The run is going fine, no error counts.

12/16/2014

The test was unexpectedly stopped, the computer was shut down. Starting a new run at 9:40

12/10/2014

Starting a new long run with 6042 at 17:05

12/08/2014

End of the long run with the board 6042 at 15:30. Channel 8 has 20 error counts, the rest channels don’t have any errors. IVVDC current is 415 mA, temperature is 35 C.

Testing new optoboards:

6040 - 415 mA, optical power OK, stop errors test ok

6036 - 412 mA, optical power OK, stop errors test ok

6045 - 410 mA, VCSEL2 has lower optical power (ch 8 - 15 have ~600 mA), stop errors test ok

5036 - 387 mA, optical power OK, stop errors test ok

Starting long ran test again with the same board (6042) at 16:10 - have permanent error counts at channels 8...

12/02/2014

Channel 8 has 17 error counts at 11:25 am.

12/01/2014

Channel 8 has 15 error counts, the last count was on Saturday, November 30, at ~2:30 pm

Some items were moved around the test setup, that might have affected the error counts (?)

11/25/2014

Run goes smoothly, no error counts in any channel yet

11/17/2014

Run goes smoothly, no error counts in any channel yet

11/14/2014

The run goes smoothly, no error counts appeared at 10:15 am

11/13/2014

Updated the labview code to have stop error test run permanently. Started long run using IBL optoboard 6042 at 10:02 am

11/10/2014

Using board 6042 for a long run test (~1 week)

Before the start of the run:

6042 - 410 mA, optical power OK, stop errors test ok

Temperature after ~15 mins of running is 35 C.

10/29/2014

IBL boards used in SR1 tests:

6047 - Slot 10, DBM test

6022 - Slot 5

6002 - Slot 4

6000 - Slot 2, has broken black fiber connector for VCSEL1

6005 - Slot 1

6047 - 409mA, optical power OK, stop errors test ok

09/18/2014

6042 - 414m, optical power OK, stop errors test ok

09/15/2014

4004 - 330 mA, lower optical power in VCSEL2 (~1300 uW), stop error test is OK

4082- 386 mA, Optical powers test OK, stop error test is OK

09/09/2014

Re-testing problematic boards

4016 - VCSEL1 has no optical power, VCSEL2 has very low power (~70 uW), IVVDC ~320 mA

4082 -  381 mA, error counts test OK, optical powers test OK

4004 - 389 mA, error counts test OK, optical powers test OK -- While removing, the VCSEL2 connector got broken (probably too short pin on the removal tool -- this board has a thick aluminium connector, too thick for this tool)

6004 - error counts test OK, optical powers test OK

B12002 - 376 mA, error counts bad on Doric channel 5, VCSEL channel 0, 7. VCSEL 1 has no optical power on channel 0, 1.

26/08/2014

Testing new IBL boards

6022- 403 mA, error counts test OK, optical powers test OK

6035- 382 mA, error counts test OK, optical powers test OK

old D-board:

4042- 367 mA, error counts test OK, optical powers test OK

Boards available in SR1:

D-boards: 4117, 4240, 4209, 4262, 4305, 4308, 4307, 4309, 4313, 4303, 4304, 4302, 4314, 4310, 4312, 4315, 4112 , 4306, 4294, 4297, 4300, 4301, 4299, 4296, 4290, 4286, 4293, 4005, 4042, 4027, 4011, 4085, 4055, 4012, 4018, 4015, 4013, 4017, 4019  - total 39

 

B-boards: 5065, 5064, 5021, 5004, 5012

IBL: 6046, 6055, 6056, 6057, 6054, 6051, 6052

Not tested: 4054, 4176, 5006, 5040 (bad based on the NSQP_Optoboard_QA) + 2 IBL boards from Siinn

8/18/2014

Installing board 6047 for the DBM test (slot 7 of the optobox)

8/6/2014

Testing IBL board 6042 (request from Marcello)

6042 - 406 mA, error counts test OK, optical powers OK

8/5/2014

6053 installed in A slot 14 6040 broken. webpage updated

7/18/2014

boards being taken down to the pit: 6049, 6051

        - 6049 inserted, 6051 returned to SR1 cabinet

7/8/2014

boards broken by IBL test team - 6022 - 6035

list of IBL boards in the pit:

6025 - A side slot 1

6023 - A side slot 2

6024 - A side slot 3

6028 - A side slot 4

6029 - A side slot 5

6030 - A side slot 6

6031 - A side slot 7

6032 - A side slot 8

6033 - A side slot 9

6034 - A side slot 10

6036 - A side slot 11

6038 - A side slot 12

6039 - A side slot 13

6040 - A side slot 14

6041 - A side slot 15

6007 - C side slot 1

6008 - C side slot 2

6009 - C side slot 3

6010 - C side slot 4

6011 - C side slot 5

6012 - C side slot 6

6013 - C side slot 7

6014 - C side slot 8

6015 - C side slot 9

6017 - C side slot 10

6018 - C side slot 11

6019 - C side slot 12

6020 - C side slot 13

6021 - C side slot 14

6027 - C side slot 15

6/23/2014

30 IBL boards packed and ready to go down to the pit

6/03/2014

Testing IBL boards delivered by Shane

6049 - 413 mA, error counts test OK, optical powers OK

6051 - 416 mA, error counts test OK, optical powers OK

6054 - 415 mA, error counts test OK, optical powers OK

6057 - 407 mA, error counts test OK, optical powers OK

6055 - 416 mA, error counts test OK, optical powers OK

6056 - 412 mA, error counts test OK, optical powers OK

6053 - 411 mA, error counts test OK, optical powers OK

6052 - 412 mA, error counts test OK, optical powers OK

5/15/2014

IBL board 6004 is given to Martin for the IBL optobox tests in the pit.

4/15/2014

Reception test for some boards

4151 - 389mA - all channels no errors - optical powers are fine. replacing this board in the pit fixed the problem with one module (I believe that it was module 6)

6002 - VCSEL1 has lower optical power (~800-900 uW), but should be fine for the tests in SR1. Error counts test is OK. The board is given to Martin.

5012 - Optical power OK, Stop error OK

4/8

IBL guys are breaking opto-boards carolos gave me 6022 which now has a broken VCSEL2 and 6002 which he says has no PIN current.  We need to check / fix these. Also we need to do an IBL inventory and I need to come back to install IBL.

4/1

No reception test recorded for 5048: running now

5048: 385 mA, error counts test OK, optical powers OK

No reception test recorded for 4245: running now

4245: 378 mA, error counts test OK, optical powers OK

5036 has too much hysol to fit into the opto-box

3/31

6003 given to carolos for stave 7 and 8

6002 given to carolos for stave 7 and 8

6035 given to carolos for stave 7 and 8

6026 given to me by IBL, carolos it is broken

please retest 4151 - it had a flaky module in C side FT14

notice 6003 and 6035 sitting out on the table and not packed properlyy.  Don’t use them unless absolutely necessary

03/24/2014

Retesting:

4112 - 388 mA, error counts test OK, optical powers OK

4301 - 389 mA, error counts test OK, optical powers OK

Note: 4112 was used in tests in the cavern. It will be placed in Box 1 in the cabinet in SR1.

03/20/2014

Retested board 5024: one module in one link has no error-free region

- scan #40576 (note: had vcsel 2 ribbon attached to top vcsel due to ribbon issues)

03/19/2014

5024 needs to be re-scanned

FT10 opto-boards moved to the pit

D-boards in SR1 divided into boxes:

Box 1: 4005-4103 (38)

Box 2: 4104-4151 (45)

Box 3: 4152-4208 (54)

Box 4: 4210-4244 (35)

Box 5: 4245-4301 (54)

Box 6: 4302-4315 (13)

03/18/2014

Reception test:

4055 - 353mA, error counts test OK, optical powers OK (VCSEL1 has lower optical power, ~1200-1500 uW, but it’s ok) - This board has low IVVDC, I list it as bad from now on

2D-scan:

4033 - scan #40549 -- all ok

4085 - scan #40550 -- all ok

4115 - scan #40551 -- all ok

4156 - scan #40553 -- all ok

4169 - scan #40554 -- all ok

4223 - scan #40556 -- all ok

4238 - scan #40559 -- all ok

4239 - scan #40562 -- all ok

Boards that will go to the pit tomorrow... FT10 opto-box is first to have ER bundles, opto-boards needed:

Box 1 - 0 B boards

23 D boards

 1 spare

4028

4035

4036

4037

4039

4040

4041

4044

4045

4046

4047

4052

4053

4056

4057

4059

4060

4061

4062

4065

4066

4067

4068

Box 2 - 5 B boards

17 D boards

 2 spare

5000

5001

5008

5009

5010

4069

4070

4071

4072

4073

4074

4075

4076

4077

4078

4079

4080

4081

4083

4084

4086

4087

2D scans:

5039 - scan #40517 -- all ok

5058 - scan #40519 -- all ok

5056 - scan #40520 -- all ok

5060 - scan #40521 -- all ok

5059 - scan #40526 -- all ok

5065 - scan #40534 -- all ok

5064 - scan #40539 -- all ok

5062 - scan #40540 -- all ok

5019 - scan #40547 -- all ok (one module looks slightly small due to ribbon problem)

5044 - scan #40548 -- all ok

Boards to give to Shane:

Box 1:

4005-4009, 4011-4015, 4017-4019,4022, 4024, 4027, 4028, 4030, 4032, 4035-4037, 4039, 4040-4042, 4044-4047, 4052, 4053, 4055-4057, 4059-4062, 4064-4068

Box 2:

4069-4081, 4083-4092, 4094-4111, 4113-4125

03/18/2014

4071 - scan #40453 -- all ok

4083 - scan #40456 -- all ok

4075 - scan #40457 -- all ok

4067 - scan #40458 -- all ok

4055 - scan #40460 -- all ok

4061 - scan #40461 -- all ok

4074 - scan #40462 -- all ok

4068 - scan #40464 -- all ok

4062 - scan #40465 -- all ok

4069 - scan #40466 -- all ok

4170 - scan #40467 -- all ok

4057 - scan #40468 -- all ok

4059 - scan #40469 -- all ok

4065 - scan #40471 -- all ok

4179 - scan #40473 -- all ok

4171 - scan #40475 -- all ok

4084 - scan #40476 -- all ok

4053 - scan #40478 -- all ok

4175 - scan #40480 -- all ok

4162 - scan #40481 -- all ok

4083 - scan #40482 -- all ok

4165 - scan #40484 -- all ok

4072 - scan #40485 -- all ok

4079 - scan #40487 -- all ok

4068 - scan #40488 -- all ok

4070 - scan #40490 -- all ok

4086 - scan #40492 -- all ok

4073 - scan #40493 -- all ok

4078 - scan #40494 -- all ok

4081 - scan #40495 -- all ok

4076 - scan #40496 -- all ok

4080 - scan #40497 -- all ok

4030F-scan #40498 -- all ok

4168 - scan #40501 -- all ok

4172 - scan #40502 -- all ok

4173 - scan #40503 -- all ok

4177 - scan #40505 -- all ok

4178 - scan #40509 -- all ok

4166 - scan #40511 -- all ok

4164 - scan #40513 -- all ok

4167 - scan #40514 -- all ok

Retest:

4012 - scan #40516 -- all ok

03/17/2014

4260 - scan #40393 -- all ok

4258 - scan #40394 -- all ok

4254 - scan #40396 -- all ok

4240 - scan #40398 -- all ok

4249 - scan #40399 -- all ok

4271 - scan #40400 -- all ok

4014 - scan #40402 -- all ok

4009 - scan #40404 -- all ok

4013 - scan #40406 -- all ok

4006 - scan #40408 -- all ok

4022 - scan #40411 -- problem with link 2: doing reception test

        - reception test fine after using nitrogen to blow off laser

        - scan #40418 -- all ok

4027 - scan #40413 -- all ok

4024 - scan #40416 -- all ok

4005 - scan #40419 -- all ok

4019 - scan #40423 -- problem with last channel of link 2: small area

        - reception test: everything ok

        - scan #40429 -- all ok

4060 - scan #40424 -- all ok

4008 - scan #40426 -- all ok

4274 - scan #40431 -- all ok

4007 - scan #40432 -- all ok

4017 - scan #40433 -- all ok

4018 - scan #40435 -- all ok

4016 - scan #40438 -- problems in link 2: doing reception test

        - reception test: power low in vcsel 2, IVVDC ~315 mA

        - visual inspection: one or more channels not emitting light

4015 - scan #40441 -- all ok

4012 - scan #40447 -- problems with link 1 (may be ribbon related)

        - reception test: everything ok

        - Will retest tomorrow

4011 - scan #40449 -- all ok

03/14/2014

Jens and Karolos requested boards for the test system: giving them 4002, 4003, 4082, 5023, 5003

Reception tests:

4314 - 387 mA, error counts test OK, optical powers OK

4313 - 385 mA, error counts test OK, optical powers OK

4315 - 386 mA, error counts test OK, optical powers OK

5062 - 383 mA, error counts test OK, optical powers OK

5065 - 387 mA, error counts test OK, optical powers OK

5064 - 384 mA, error counts test OK, optical powers OK

2D scans:

4233 - scan #40347 -- all ok

4270 - scan #40348 -- all ok

4253 - scan #40350 -- all ok

4276 - scan #40351 -- all ok

4268 - scan #40353 -- all ok

4272 - scan #40355 -- all ok

4257 - scan #40356 -- all ok

4315 - scan #40357 -- all ok

4313 - scan #40359 -- all ok

4314 - scan #40361 -- all ok

4056R-scan #40362 -- all ok

4039R-scan #40363 -- all ok

4036R-scan #40364 -- all ok

4035R-scan #40365 -- all ok

4261 - scan #40366 -- all ok

4262 - scan #40368 -- all ok

4264 - scan #40369 -- all ok

4277 - scan #40374 -- problem with link 2

        - redid reception test, all ok

        - scan #40378 -- all ok

4278 - scan #40375 -- all ok

4256 - scan #40376 -- all ok

4275 - scan #40379 -- all ok

4259 - scan #40380 -- all ok

4263 - scan #40381 -- all ok

4242 - scan #40382 -- all ok

4267 - scan #40383 -- all ok

4241 - scan #40384 -- all ok

4266 - scan #40385 -- all ok

4273 - scan #40386 -- all ok

4255 - scan #40387 -- all ok

4265 - scan #40389 -- all ok

03/13/2014

2D scans:

4301 - scan #40311 -- all ok

4302 - scan #40312 -- all ok

4296 - scan #40313 -- all ok

4304 - scan #40314 -- all ok

4306 - scan #40315 -- all ok

4281 - scan #40316 -- all ok

4283 - scan #40317 -- all ok

4289 - scan #40318 -- all ok

4288 - scan #40320 -- all ok

4290 - scan #40321 -- all ok

4292 - scan #40322 -- all ok

4101 - scan #40323 -- all ok

4280 - scan #40324 -- all ok

4285 - scan #40327 -- all ok

4295 - scan #40328 -- all ok

4312 - scan #40329 -- all ok

4297 - scan #40330 -- all ok

4298 - scan #40331 -- all ok

4064F-scan #40333 -- all ok

4308 - scan #40334 -- all ok

4310 - scan #40335 -- all ok

4286 - scan #40336 -- all ok

4282 - scan #40337 -- all ok

4174 - scan #40338 -- all ok

4303 - scan #40339 -- all ok

4309 - scan #40340 -- all ok

4294 - scan #40341 -- all ok

4307 - scan #40342 -- all ok

4305 - scan #40343 -- all ok

4293 - scan #40344 -- all ok

4299 - scan #40345 -- all ok

4300 - scan #40346 -- all ok

03/11/2014

Shane looked at the optical signal from 5024: board is fine.

03/10/2014

2D scans:

4103 - scan #40242 -- all ok

4114 - scan #40243 -- all ok

4110 - scan #40245 -- all ok

4091 - scan #40247 -- all ok

4158 - scan #40248 -- all ok

4089 - scan #40249 -- all ok

4149 - scan #40250 -- all ok

4151 - scan #40251 -- all ok

4105 - scan #40252 -- all ok

4102 - scan #40253 -- all ok

4148 - scan #40254 -- all ok

4147 - scan #40255 -- all ok

4093 - scan #40256 -- all ok

4125 - scan #40257 -- all ok

4096 - scan #40258 -- all ok

4106 - scan #40259 -- all ok

4066 - scan #40261 -- all ok

4152 - scan #40264 -- all ok

4113 - scan #40265 -- all ok

4143 - scan #40267 -- all ok

4077 - scan #40268 -- all ok

4139 - scan #40269 -- all ok

4097 - scan #40270 -- all ok

4160 - scan #40271 -- all ok

4154 - scan #40272 -- all ok

4108 - scan #40273 -- all ok

4155 - scan #40274 -- all ok

4146 - scan #40276 -- all ok

4098 - scan #40279 -- all ok

4109 - scan #40281 -- all ok

4104 - scan #40282 -- all ok

4157 - scan #40283 -- all ok

4140 - scan #40284 -- all ok

4092 - scan #40286 -- all ok

4116 - scan #40287 -- all ok

4153 - scan #40290 -- problem with last channel in both links

4099 - scan #40293 -- problem with last channel in both links

→ may have had temporary module problem

4095 - scan #40294 -- all ok

-->redid reception test on 4153, everything ok: retesting

4099 - scan #40295 -- all ok

4153 - scan #40296 -- all ok

4111 - scan #40297 -- all ok

4141 - scan #40298 -- all ok

4279 - scan #40299 -- all ok

4284 - scan #40300 -- all ok

4291 - scan #40301 -- all ok

4032F-scan #40304 -- all ok

03/07/2014

2D scans:

4236 - scan #40182 -- all ok

4248 - scan #40184 -- all ok

4227 - scan #40185 -- all ok

4199 - scan #40186 -- all ok

4195 - scan #40187 -- all ok

4221 - scan #40188 -- all ok

4213 - scan #40189 -- all ok

4211 - scan #40190 -- all ok

4245 - scan #40191 -- all ok

4198 - scan #40192 -- all ok

4231 - scan #40194 -- all ok

4161 - scan #40195 -- all ok

4229 - scan #40196 -- all ok

4243 - scan #40197 -- all ok

4197 - scan #40199 -- all ok

4216 - scan #40200 -- all ok

4252 - scan #40201 -- all ok

4247 - scan #40202 -- all ok

4250 - scan #40203 -- all ok

4203 - scan #40204 -- all ok

4217 - scan #40206 -- all ok

4233 - scan #40207 -- all ok

4249 - scan #40208 -- all ok

4226 - scan #40210 -- all ok

4230 - scan #40211 -- all ok

4235 - scan #40212 -- all ok

4244 - scan #40215 -- all ok

4220 - scan #40216 -- all ok

4246 - scan #40217 -- all ok

4210 - scan #40218 -- all ok

4214 - scan #40219 -- all ok

4219 - scan #40220 -- all ok

4212 - scan #40221 -- all ok

4228 - scan #40223 -- all ok

4222 - scan #40224 -- all ok

4234 - scan #40225 -- all ok

4215 - scan #40226 -- all ok

4256 - scan #40227 -- all ok

4088 - scan #40228 -- all ok

4120 - scan #40229 -- all ok

4100 - scan #40230 -- all ok

4145 - scan #40231 -- all ok

4159 - scan #40232 -- all ok

4090 - scan #40233 -- all ok

4105 - scan #40234 -- all ok

4142 - scan #40235 -- all ok

4087 - scan #40236 -- all ok

4117 - scan #40237 -- all ok

4150 - scan #40238 -- all ok

4107 - scan #40239 -- all ok

4124 - scan #40241 -- all ok

03/06/2014

2D scans:

4218 - scan #40174 -- all ok

4224 - scan #40175 -- all ok

4225 - scan #40176 -- all ok

4232 - scan #40177 -- all ok

4237 - scan #40179 -- all ok

03/04/2014

Board 4200 was dropped when removing from optobox 4200, redid reception test:

4200 - 386 mA, error counts test OK, optical powers OK

4209 was dropped when removing from the optobox: connector for vcsel 1 is cracked.

2D scans:

4200 - scan #40111 -- all ok

4193 - scan #40112 -- all ok

4192 - scan #40113 -- all ok

4206 - scan #40114 -- all ok

4183 - scan #40115 -- all ok

4188 - scan #40116 -- all ok

4190 - scan #40117 -- all ok

4209 - scan #40119 -- all ok

4186 - scan #40120 -- all ok

4045F-scan #40121 -- all ok

4047F-scan #40122 -- all ok

4046F-scan #40123 -- all ok

4189 - scan #40125 -- all ok

4187 - scan #40126 -- all ok

4042F-scan #40127 -- all ok

4040 - scan #40128 -- all ok

4052 - scan #40129 -- all ok

4044 - scan #40134 -- all ok

4041F-scan #40135 -- all ok

4205 - scan #40136 -- all ok

4204 - scan #40137 -- all ok

4028 - scan #40138 -- all ok

4181 - scan #40139 -- all ok

4131 - scan #40140 -- all ok

4208 - scan #40141 -- all ok

4191 - scan #40142 -- all ok

4184 - scan #40143 -- all ok

4037F-scan #40144 -- all ok

4202 - scan #40146 -- all ok

4203 - scan #40147 -- all ok

4201 - scan #40148 -- all ok

4185 - scan #40149 -- all ok

4207 - scan #40150 -- all ok

4180 - scan #40152 -- all ok

4194 - scan #40153 -- all ok

4133 - scan #40154 -- all ok

4118 - scan #40155 -- all ok

4128 - scan #40156 -- all ok

4129 - scan #40157 -- all ok

4182 - scan #40158 -- all ok

4121 - scan #40159 -- all ok

4138 - scan #40160 -- all ok

4135 - scan #40161 -- all ok

4132 - scan #40162 -- all ok

4137 - scan #40163 -- all ok

4123 - scan #40164 -- all ok

4122 - scan #40166 -- all ok

4127 - scan #40168 -- all ok

4134 - scan #40169 -- all ok

4130 - scan #40170 -- all ok

4119 - scan #40171 -- all ok

4126 - scan #40173 -- all ok

02/26/2014

Optobox needs to be re-adjusted to be able to fit the optoboards

Shane took boards 4082 and 5003 for adjusting.

Other boards given to Rusty on Jan 24 are still in use for optobox production.

============================

02/25/2014

Reception tests for boards brought by Shane:

4310 - 385 mA, error counts test OK, optical powers OK

4309 - 387 mA, error counts test OK, optical powers OK

4295 - 390 mA, error counts test OK, optical powers OK

4292 - 386 mA, error counts test OK, optical powers OK

4302 - 387 mA, error counts test OK, optical powers OK

4294 - 388 mA, error counts test OK, optical powers OK

4301 - 393 mA, error counts test OK, optical powers OK

4312 - 388 mA, error counts test OK, optical powers OK

4299 - 390 mA, error counts test OK, optical powers OK

4307 - 387 mA, error counts test OK, optical powers OK

4297 - 386 mA, error counts test OK, optical powers OK

4296 - 388 mA, error counts test OK, optical powers OK

4306 - 385 mA, error counts test OK, optical powers OK

4304 - 383 mA, error counts test OK, optical powers OK

4303 - 395 mA, error counts test OK, optical powers OK

4308 - 385 mA, error counts test OK, optical powers OK

4298 - 389 mA, error counts test OK, optical powers OK

4300 - 382 mA, error counts test OK, optical powers OK

4305 - 391 mA, error counts test OK, optical powers OK

4293 - 387 mA, error counts test OK, optical powers OK

5024 - 370 mA, cannot remove errors in one channel of vcsel 2, optical powers OK

Problem: attempted to use new optobox to perform 2D scan of board 5057. 80-pin connector on both board and ER bundle had pin on connector bent upon insertion.

02/07/2014

Testing new boards brought by Harris:

5058 - 385 mA, error counts test OK, optical powers OK

5056 - 382 mA, error counts test OK, optical powers OK

5059 - 384 mA, error counts test OK, optical powers OK

5057 - 381 mA, error counts test OK, optical powers OK

5039 - 388 mA, error counts test OK, optical powers OK

5060 - 380 mA, error counts test OK, optical powers OK

4279 - 388 mA, error counts test OK, optical powers OK

4101 - 387 mA, error counts test OK, optical powers OK

4282 - 385 mA, error counts test OK, optical powers OK

4174 - 381 mA, error counts test OK, optical powers OK

4280 - 387 mA, error counts test OK, optical powers OK

4290 - 378 mA, error counts test OK, optical powers OK

4291 - 385 mA, error counts test OK, optical powers OK

4286 - 384 mA, error counts test OK, optical powers OK

4289 - 388 mA, error counts test OK, optical powers OK

4283 - 391 mA, error counts test OK, optical powers OK

4281 - 384 mA, error counts test OK, optical powers OK

4285 - 384 mA, error counts test OK, optical powers OK

4284 - 385 mA, error counts test OK, optical powers OK

4032 - 387 mA, error counts test OK, optical powers OK

4064 - 386 mA, error counts test OK, optical powers OK

4288 - 385 mA, error counts test OK, optical powers OK

02/05/2014

4017 - 379 mA, error counts test OK, optical powers OK

03/02/2014

Steven got board 4112 for the pixel tests in the pit.

==========================

01/31/2014

Board 4112 is given to Karolos for the toothpix tests (reception test is good)

4112 - scan 40059 (line 1, link 1 has problem)

5024 - scan 40060 -- all OK!

5034 - scan 40062 -- all OK!

5036 - scan 40063 and 40065 -- all OK!! -- 3D scan - 40064

reception test:

5024 - 371 mA, Channel 12 (fiber space) has permanent errors ~1 per sec at delay 13

4085 - 383 mA, all ok.

===========================

01/30/2014

2D scans::

5050 - scan #40043 -- all ok

5024 - cannot get correct IVdc

5037 - scan #40053 -- all ok (after cleaning optical fiber)

5034 - cannot get correct IVdc (was tested OK yesterday?)

5036 - scan #40057 - links 5 and 7 have errors. Reception test is normal.

===========================

01/29/2014

2D scans:

5024 - scans 40010 and 40009 when the board was connected to slots 13 and 14 correspondingly, showed the last channel (bottom-right on the plots) with no error-free region.

Reception test for 5024 - 372 mA, optical test OK, ch 12 (in fiber space) has errors

Using tested before board to find a good slot

5004 - scan 40011 is for slot 13 and 40012 for slot 14 (both are OK)

2D scans:

5038 - scan #40017 -- all ok

5046 - scan #40018 -- all ok

5028 - scan #40019 -- all ok

5025 - scan #40020 -- all ok

5047 - scan #40021 -- all ok

5035 - scan #40022 -- all ok

5049 - scan #40023 -- all ok

5052 - scan #40024 -- all ok

5053 - scan #40025 -- all ok

5036 - scan #40026 -- problem with last channel in link 1 and 2

5034 - scan #40030 -- all ok

5055 - scan #40031 -- all ok

5041 - scan #40032 -- all ok

5027 - scan #40033 -- all ok

5051 - scan #40034 -- all ok

5045 - scan #40035 -- all ok

5037 - scan #40037 -- problem with one channel in link 1 and 2

5043 - scan #40038 -- all ok

5030- scan #40040 -- all ok

5034 - not possible to turn on (VIset is low for both slot 13 and slot 14)

===============================

01/28/2014

2D-scans:

5042 - scan #39996 -- channel 3 has no error free region.

The panel doesn’t show correctly the IPin current, and the board IVVDC iis not set properly after turning on the board. Moved to Slot 13 - works fine (except still no IPin current displayed)

5033 - scan #40000 -- all OK

Checked the PP2 cable with Kerstin -seems to be fine

Slot 14 of the otobox has bent pin.

5024 - scan #40005 -- 2 last channels are not good  and #40008 - only one channels is not good.

When slot 13 is used, 3D scan is not possible, because it’s not possible to change the VIset

================================

1/27/2014

Reception test:

4267 - 390 mA, error counts test OK, optical powers OK

4261 - 385 mA, error counts test OK, optical powers OK

4258 - 386 mA, error counts test OK, optical powers OK

4260 - 382 mA, error counts test OK, optical powers OK

4256 - 380 mA, error counts test OK, optical powers OK

4262 - 386 mA, error counts test OK, optical powers OK

4277 - 385 mA, error counts test OK, optical powers OK

4254 - 382 mA, error counts test OK, optical powers OK

4275 - 387 mA, error counts test OK, optical powers OK

4264 - 385 mA, error counts test OK, optical powers OK

4263 - 385 mA, error counts test OK, optical powers OK

4278 - 387 mA, error counts test OK, optical powers OK

4035R - 384 mA, error counts test OK, optical powers OK

4039R - 363 mA, error counts test OK, optical powers OK

4259 - 386 mA, error counts test OK, optical powers OK

4036R - 384 mA, error counts test OK, optical powers OK

4056R - 380 mA, error counts test OK, optical powers OK

4276 - 381 mA, error counts test OK, optical powers OK

4033R - 392 mA, error counts test OK, optical powers low in VCSEL 1 (1300-1400 uW)

4255 - 380 mA, error counts test OK, optical powers OK

4242 - 378 mA, error counts test OK, optical powers OK

4270 - 388 mA, error counts test OK, optical power OK

4239 - 386 mA, error counts test OK, optical power OK

4273 - 387 mA, error counts test OK, optical power OK

4241 - 387 mA, error counts test OK, optical power OK

4274 - 380 mA, error counts test OK, optical power OK

4265 - 392 mA, error counts test OK, optical power OK

4266 - 388 mA, error counts test OK, optical power OK

4268 - 390 mA, error counts test OK, optical power OK

4257 - 382 mA, error counts test OK, optical power OK

4253 - 386 mA, error counts test OK, optical power OK

4272 - 387 mA, error counts test OK, optical power OK

4240 - 391 mA, error counts test OK, optical power OK

4271 - 386 mA, error counts test OK, optical power OK

4238 - 385 mA, error counts test OK, optical power OK

4033R -- retest: VCSEL 1 still low (1200-1400 uW)

5050 -- redid reception test, error counts test OK, optical powers OK

5042 -- no power from VCSEL 1, channel 3

1/25/2014

Reception tests for boards brought by Harris:

4258 - 382 mA, error counts test OK

→ Had to stop, was having trouble getting optical power test to run. Will look at the setup more closely Monday.

01/24/2014

Gave 5020 to Harris to take back to OSU.

Reception test for B-boards:

5050 - 384 mA, error counts test OK, optical power OK

5042 - 380 mA, channel 8 - permanent errors for all delays and no normal signal on oscilloscope, channel 3 has 0 optical power

B-boards that were previously used in nsqp tests: 5003, 5020, x

New boards to give to Rusty: 4163, 5040, 4054, 6071, 5005, 4023, 4025, 4176, 4038, 5006,  6068, 5061, 6070, 6069.

-- 4 IBL, 4 B-type, 6 D-type

Worked with Jens and found that there was a problem with one of the read-out connectors, which was likely causing some of our issues with previous b-board scans.

2D-scans:

5023 - scan #39967 -- all ok

5026 - scan #39968 -- all ok

5018 - scan #39973 -- all ok

5020 - no temperature readout and visible damage to pin connector

5004 - scan #39975 -- all ok

5001 - scan #39977 -- all ok

5029 - scan #39978 -- all ok

retest: 5013 - scan #39979 -- all ok

5048 - scan #39980 -- all ok

5042 - scan #39982 -- no error free region for two readouts (did 3D scan)

5031 - scan #39983 -- all ok

5050 - scan #39987 -- no error free region for two readouts (did 3D scan)

5054 - scan #39988 -- all ok

01/21/2014

Giving boards to Rusty for use in aligning parts for optobox assembly:

boards -- 4082, 5003, B12002, B12005, 4003, 4002, 4112, 4001, 4004, 5004

        - just kidding, giving broken boards from Harris

Retesting boards from yesterday: Jens pointed out that module currents were not always correct on start-up.

5021 - scan #39920 -- all ok

5011 - scan #39925 -- all ok

5012 - scan #39926 -- all ok

5008 - scan #39927 -- all ok

Jens is changing RX plug at the BOC due to channel 6 narrow error-free region  

5013 - lack of error-free region in one channel: Jens suspects the optical power from the channel may be too high.

5014- scan #39940 -- all ok

================================================

01/20/2014

2D scans:

5000 - scan #39906 -- all ok

5008 - scan #39907 : L2_B27_S2_A7_M5A -- no error free region

5021 - scan #39908: L2_B27_S2_A7_M2A -- no error free region

5017 - scan #39909 -- all ok

5011 - scan #39910: L2_B27_S2_A7_M6A, L2_B27_S2_A7_M3A -- no error free region

5022 - scan #39911 -- all ok

5010 - scan #39912 -- all ok

5016 - scan #39913 -- all ok

5009 - scan #39914 -- all ok

5012 - scan #39915: L2_B27_S2_A7_M3A -- no error free region

-- talked to Tayfun: need to be able to change VIset to properly test boards for error-free region

01/16/2014

Making 2D scans for the B-boards

5003 - fine

==================================

01/15/2014

IBL board 6037 got VCSEL2 connector broken.

6022 and 6045 plan to give to Daniel. Connection test is fine.

Board 6003 and 6004 are used in toothpix test.

==================================

01/10/2014

Re-testing 2 optoboards

4213 - 384 mA, error counts test OK, optical powers test OK

4196 - 381 mA, optical powers test OK, VCSEL1 channel 2 has error counts for all delay, even after cleaning with dry air. No evidence for dust visible in microscope.

===================================

1/8/2014

4228 - 384 mA, error counts test OK, optical powers test OK

4246 - 375 mA, error counts test OK, optical powers test OK

        -- NOTE: board was dropped being removed from box before testing

4229 - 388 mA, error counts test OK, optical powers test OK

4227 - 381 mA, error counts test OK, optical powers test OK

4248 - 380 mA, error counts and clock errors in doric channel 3, optical powers test OK

4252 - 382 mA, error counts test OK, optical powers test OK

4195 - 385 mA, error counts test OK, optical powers test OK

4199 - 384 mA, error counts test OK, optical powers test OK

4236 - 380 mA, error counts test OK, optical powers test OK

4214 - 385 mA, error counts test OK, optical powers test OK

4231 - 386 mA, error counts test OK, optical powers low and variable

4247 - 382 mA, error counts test OK, optical powers test OK

4221 - 384 mA, error counts test OK, optical powers test OK

4223 - 380 mA, error counts test OK, optical powers test OK

4250 - 381 mA, error counts test OK, optical powers test OK

4249 - 379 mA, error counts test OK, optical powers test OK

4237 - 383 mA, error counts test OK, optical powers test OK

4230 - 386 mA, error counts test OK, optical powers test OK

4219 - 382 mA, error counts test OK, optical powers test OK

4220 - 387 mA, error counts test OK, optical powers test OK

4198 - 382 mA, error counts test OK, optical powers test lowish (1100-1500 uW)

4235 - 383 mA, error counts test OK, optical powers test OK

4224 - 385 mA, error counts test OK, optical powers test OK

4243 - 385 mA, error counts test OK, optical powers test OK

4212 - 383 mA, error counts test OK, optical powers test OK

4235 - 382 mA, error counts test OK, optical powers test OK

4222 - 382 mA, error counts test OK, optical powers test OK

4234 - 385 mA, error counts test OK, optical powers test OK

4296 - 387 mA, errors in vcsel 1, ch 2, optical powers test OK

4244 - 383 mA, error counts test OK, optical powers test OK

4213 - 384 mA, error counts test OK, vcsel 2 powers slightly low (1100-1500 uW)

4211 - 380 mA, error counts test OK, optical powers test OK

4210 - 387 mA, error counts test OK, optical powers test OK

4226 - 388 mA, error counts test OK, optical powers test OK

4233 - 384 mA, error counts test OK, optical powers test OK

4217 - 385 mA, error counts test OK, optical powers test OK

4215 - 382 mA, error counts test OK, optical powers test OK

4216 - 380 mA, error counts test OK, optical powers test OK

4218 - 385 mA, error counts test OK, optical powers test OK

4225 - 382 mA, error counts test OK, optical powers test OK

4232 - 384 mA, error counts test OK, optical powers test OK

4197 - 382 mA, error counts test OK, optical powers test OK

retest:

4248 - 380 mA, error counts test OK, optical powers test OK

4231 - 384 mA, error counts test OK, optical powers test OK

4198 - 380 mA, error counts test OK, optical powers test OK

4196 - 382 mA, errors in VCSEL 1, ch 2, optical powers test OK

======================================

12/20/2013

Re-testing and sending back to OSU with KK the following boards:

4032, 4064, 5039.

======================================

12/19/2013

Continue testing new boards

4028 - 385 mA, error counts test OK, optical powers test OK

4028 - 379 mA, error counts test OK, optical powers test OK

4032 - 393 mA, VCSEL1 channels have no optical power (40 uW) and produce error counts.

4042 - 362 mA, error counts test OK, optical powers test OK

4030 - 385 mA, error counts test OK, channel 7 has lower optical power (~1200 uW)

4202 - 388 mA, error counts test OK, optical powers test OK

4204 - 387 mA, error counts test OK, optical powers test OK

4203 - 382 mA, error counts test OK, optical powers test OK

4201 - 387 mA, error counts test OK, optical powers test OK

4200 - 387 mA, error counts test OK, optical powers test OK

================================

12/18/2013

One of the IBL boards without optical power recorded:

6035 - 405 mA, error counts test OK, optical powers test OK

Testing new boards delivered by KK:

4180 - 384 mA, error counts test OK, optical powers test OK

4183 - 382 mA, error counts test OK, optical powers test OK

4181 - 384 mA, error counts test OK, optical powers test OK

4184 - 380 mA, error counts test OK, optical powers test OK

4045 - 386 mA, error counts test OK, optical powers test OK

4186 - 384 mA, error counts test OK, optical powers test OK

4188 - 379 mA, error counts test OK, optical powers test OK

4187 - 384 mA, error counts test OK, optical powers test OK

4182 - 385 mA, error counts test OK, optical powers test OK

4189 - 376 mA, error counts test OK, optical powers test OK

4209 - 387 mA, error counts test OK, optical powers test OK

4206 - 382 mA, error counts test OK, optical powers test OK

4207 - 381 mA, error counts test OK, optical powers test OK

4205 - 385 mA, error counts test OK, optical powers test OK

4208 - 380 mA, error counts test OK, optical powers test OK

4190 - 384 mA, error counts test OK, optical powers test OK

4191 - 385 mA, error counts test OK, optical powers test OK

4192 - 382 mA, error counts test OK, optical powers test OK

4193 - 382 mA, error counts test OK, optical powers test OK

4194 - 383 mA, error counts test OK, optical powers test OK

4046 - 387 mA, error counts test OK, optical powers test OK

4044 - 382 mA, error counts test OK, optical powers test OK

4041 - 380 mA, error counts test OK, optical powers test OK

4047 - 379 mA, error counts test OK, optical powers test OK

4037 - 388 mA, error counts test OK, optical powers test OK

4131 - 390 mA, error counts test OK, optical powers test OK

4053 - 380 mA, error counts test OK, optical power low in Ch0 (~1300uW)

4052 - 385 mA, error counts test OK, optical powers test OK

4064 - 385 mA, error counts test OK, optical power low in VCSEL 2 (~600-1300uW) all channels

4185 - 382 mA, error counts test OK, optical powers test OK

====================================

12/17/2013

4066 - 382 mA, error counts test OK, optical powers OK

5039 - 387 mA, error counts test OK, vcsel2 has lower optical power (down to 1000uW)

Gave 4 IBL 6037, 6003, 6035, 6026 to Daniel for the IBL  

==========================================

12/16/2013

Testing boards requested by Yi

5023 - 387 mA, error counts test OK, optical powers OK

5026 - 382 mA, error counts test OK, optical powers OK

4161 - 386 mA, error counts test OK, optical powers OK

5003 - 382 mA, error counts test OK, optical powers OK (slightly low vcsel 1, ch 3: ~1400 uW)

5004 - 385 mA, error counts test OK, optical powers OK

==========================================

11/29/2013

Took the optoboards used in the connection test back to the SR1 (boards 5003 and 5023; 4082 and 4112), as well as board 5004.

Testing board B12005 (used in toothpix test)

B12005 - 375 mA, error counts test OK, optical powers OK

==========================================

11/08/2013

Testing a new batch delivered by Harris

4177 - 386 mA, error counts test OK, optical powers OK

4178 - 387 mA, error counts test OK, optical powers OK

4171 - 387 mA, error counts test OK, optical powers OK

4175 - 388 mA, error counts test OK, optical powers OK

4174 - 382 mA, error counts test OK, channel 10 has lower optical power (1100 uW)

4170 - 378 mA, error counts test OK, optical powers OK

4168 - 375 mA, error counts test OK, optical powers OK

4179 - 386 mA, error counts test OK, optical powers OK

4161 - 386 mA, error counts test OK, optical powers OK

4172 - 384 mA, error counts test OK, optical powers OK

4166 - 380 mA, error counts test OK, optical powers OK

4162 - 392 mA, error counts test OK, optical powers OK

4173 - 379 mA, error counts test OK, optical powers OK

4164 - 383 mA, error counts test OK, optical powers OK

4169 - 381 mA, error counts test OK, optical powers OK

4167 - 384 mA, error counts test OK, optical powers OK

4165 - 385 mA, error counts test OK, optical powers OK

re-testing 4174:

4174 - 385 mA, error counts test OK, optical powers OK

=======================================

11/07/2013

Re-testing again “problematic” boards from the last batch

4139 - 372 mA, error counts test OK, optical powers OK (required 4 test before optical power was OK)

4125 - 384 mA, error counts test OK, optical powers OK (required 3 test before optical power was OK)

4120 - 381 mA, error counts test OK, optical powers OK (required 4 test before optical power was OK)

4124  - 387 mA, error counts test OK, optical powers OK

-------------------------------------------

Testing 5 random older boards, from the 1st batch.

4013 - 383 mA, error counts test OK, optical powers OK

4009 - 369 mA, error counts test OK, optical powers OK

4019 - 395 mA, error counts test OK, optical powers OK

4001 - 320 mA, error counts from VCSEL2, optical power is absent for all channels from VCSEL2 (ch 7-13) - This board was not supposed to be used in installation.

4060 - 385 mA, error counts test OK, optical powers OK

----------------

4137 is not at CERN

----------------

=====================================

11/05/2013

Testing new batch of D-boards delivered by Richard.

4127 - 387 mA, error counts test OK, optical powers OK

4130 - 384 mA, error counts test OK, optical powers OK

4132 - 385 mA, error counts test OK, optical powers OK

4121 - 377 mA, error counts test OK, optical powers OK

4125 - 383 mA, error counts test OK, optical powers OK - iset (?)

4134 - 381 mA, error counts test OK, optical powers OK

4129 - 386 mA, error counts test OK, optical powers OK

4122 - 385 mA, error counts test OK, optical powers OK

4126 - 383 mA, error counts test OK, optical powers OK

4137 - 382 mA, error counts test OK, optical powers OK

4123 - 394 mA, error counts test OK, optical powers OK

4128 - 386 mA, error counts test OK, optical powers OK

4138 - 384 mA, error counts test OK, optical powers OK

4135 - 384 mA, error counts test OK, optical powers OK

4133 - 391 mA, error counts test OK, optical powers OK

4119 - 377 mA, error counts test OK, optical powers OK

4120 - 381 mA, error counts test OK, VCSEL1 has low optical powers (~400 uW)

4139 - 369 mA, Channels 0, 1, 7-13 have error counts, lower optical power in VCSEL1 and practically no light in VCSEL2  (40 -50 uW).

4124 -mA, same problems...

re-testing previously tested board:

4138 - 384 mA, error counts test OK, optical powers OK

4118 - 381 mA, error counts test OK, optical powers OK

-------------------------------------

Testing boards taken by KK

4148 - 389 mA, error counts test OK, optical powers OK

4143 - 382 mA, error counts test OK, optical powers OK

4142 - 382 mA, error counts test OK, optical powers OK

4149 - 385 mA, error counts test OK, optical powers OK

4147  - 382 mA, error counts test OK, optical powers OK

4141  - 379 mA, error counts test OK, optical powers OK

4140 - 383 mA, error counts test OK, optical powers OK

4146 - 381 mA, error counts test OK, optical powers OK

4152 - 386 mA, error counts test OK, optical powers OK

4145 - 379 mA, error counts test OK, optical powers OK

4156 - 383 mA, error counts test OK, optical powers OK

4158 - 382 mA, error counts test OK, optical powers OK

4150 - 380 mA, error counts test OK, optical powers OK

4157 - 387 mA, error counts test OK, optical powers OK

4154 - 382 mA, error counts test OK, optical powers OK

4153 - 380 mA, error counts test OK, optical powers OK

4159 - 388 mA, error counts test OK, optical powers OK

4151 - 387 mA, error counts test OK, optical powers OK

4160 - 388 mA, error counts test OK, optical powers OK

4155 - 374 mA, error counts test OK, optical powers OK

-----------------------

Re-testing “problematic” boards

4124 - 382 mA, Channels 7, 8, 9, 10, 11, 12, 13 (VCSEL2) - show error counts for all delays. VCSEL1  channnels have normal power, VCSEL2 - very low (~40 uW).

4139 -  372 mA, error counts test OK, optical powers OK (a little lower in VSEL1, ~1500 uW)

4120 - 383 mA, error counts test OK, optical powers is lower for all VCSEL1 channels (~800 uW)

4125 - 380 mA, error counts test OK, optical powers OK

===============================================================

10/31/2013

Testing new problematic board 4064. Tayfun claims it has readout problem with one of the VCSEL channels, and this problem is not stable, sometimes it disappears in the same setup.

To replace this optoboard, I gave him another one from the newest batch - #4112.

4064 - 385 mA, Channels 7, 8, 9, 10 have lower optical power (~1300).

VCSEL1 connector is not stable. The black optical fiber connector is shaking, and if I change a little fiber’s position, channel 0 starts having error counts. This is also visible in oscilloscope (some error counts curves, plus the shape of the signal is a little different). If I press the cable down, the errors disappear. This doesn’t happen with DORIC or VCSEL2 (the fiber connectors are glued strongly). Only VDC channel 0 has this issue.

====================================================

10/29/2013

Testing the rest of optoboards

4100 - 382 mA, error counts test OK, optical powers OK

4116 - 389 mA, error counts test OK, optical powers OK

4091 - 378 mA, error counts test OK, optical powers OK

4102 - 383 mA, error counts test OK, optical powers OK

4093 - 374 mA, error counts test OK, optical powers OK

4099 - 391 mA, error counts test OK, optical powers OK

4087 - 382 mA, error counts test OK, optical powers OK

4092 - 366 mA, error counts test OK, optical powers OK

4095 - 382 mA, error counts test OK, optical powers OK

4096 - 388 mA, error counts test OK, optical powers OK

4088 - 380 mA, error counts test OK, optical powers OK

4117 - 386 mA, error counts test OK, optical powers OK

4108 - 387 mA, error counts test OK, optical powers OK

4098 - 380 mA, error counts test OK, optical powers OK

4112 - 381 mA, error counts test OK, optical powers OK

Re-testing problematic one:

4101 - 387 mA, channels 0, 5, 6 and 11 have error counts, VCSEL1 has lower optical power for all channels (120-190 uW).

=============================================

10/28/2013

31 new optoboards recieved.

5014 - 377 mA, error counts test OK, optical powers OK

4101 - 383 mA, error counts from channel 0 and channel 6, the optical powers from VCSEL1 are very low (~100 uW)

4114 - 382 mA, error counts test OK, optical powers OK

4089 - 373 mA, error counts test OK, optical powers OK

4109 - 382 mA, error counts test OK, optical powers OK

4104 - 383 mA, error counts test OK, optical powers OK

4090 - 385 mA, error counts test OK, optical powers OK

4106 - 388 mA, error counts test OK, optical powers OK

4113 - 384 mA, error counts test OK, optical powers OK

4103 - 386 mA, error counts test OK, optical powers OK

4097 - 378 mA, error counts test OK, optical powers OK

4105 - 385 mA, error counts test OK, optical powers OK

4111 - 382 mA, error counts test OK, optical powers OK

4107 - 380 mA, error counts test OK, optical powers OK

4110 - 382 mA, error counts test OK, optical powers OK

4115 - 384 mA, error counts test OK, optical powers OK

====================================================

Board 5009

 Iset                 Iset readout         IVVDC                VVDC                Ipin                RetIpin1        RetIpi2

0                0.0415                242

0.18                0.174                274

0.2                0.198                276

0.3                0.297                284

0.5                0.508                300

1.0                0.98                330

1.5                1.52                363

2.0                2.0                384

0                0.064                244

=========================================

10/01/2013

4086 - IVVDC = 379 mA, error counts test OK, optical powers are OK

4065 - IVVDC = 380 mA, error counts test OK, optical powers are OK

4068 - IVVDC = 379 mA, error counts test OK, optical powers are OK

4067 - IVVDC = 382 mA, error counts test OK, optical powers are OK

4070 - IVVDC = 381 mA, error counts test OK, optical powers are OK

4069 - IVVDC = 378 mA, error counts test OK, optical powers are OK

4071 - IVVDC = 382 mA, error counts test OK, optical powers are OK

4074 - IVVDC = 382 mA, error counts test OK, optical powers are OK

4073 - IVVDC = 380 mA, error counts test OK, optical powers are OK

4076 - IVVDC = 382 mA, error counts test OK, optical powers are OK

4072 - IVVDC = 384 mA, error counts test OK, optical powers are OK

4066 - IVVDC = 380 mA, error counts test OK, optical powers are OK

4078 - IVVDC = 381 mA, error counts test OK, optical powers are OK

4083 - IVVDC = 382 mA, error counts test OK, optical powers are OK

4084 - IVVDC = 381 mA, error counts test OK, optical powers are OK

4085 - IVVDC = 383 mA, error counts test OK, optical powers are OK

4079 - IVVDC = 380 mA, error counts test OK, optical powers are OK

4075 - IVVDC = 383 mA, error counts test OK, optical powers are OK

4077 - IVVDC = 375 mA, error counts test OK, optical powers are OK

4080 - IVVDC = 378 mA, error counts test OK, optical powers are OK

4081 - IVVDC = 380 mA, error counts test OK, optical powers are OK

4082 - IVVDC = 380 mA, error counts test OK, optical powers are OK

-----------------------

Test for Jense with different Iset

Board 4082

 Iset                 Iset readout         IVVDC                VVDC                Ipin                RetIpin1        RetIpi2

2mA                2.0 mA                380 mA

1.5mA                1.55                361

1 mA                1.01                327                2.47                957u                2.31u                 784n

0.5mA                0.51                294                2.46                957u                2.19u                784n

0.3                0.295                279        

0.2                0.193                270                

0.18                0.150                267

Optical powers:

4082        10/1/2013 4:26:16 PM        2.329938E+3        2.286111E+3        2.656759E+3        2.713150E+3        2.655241E+3        2.279792E+3        2.964535E+3        2.700578E+3        2.396416E+3        2.532687E+3        2.321496E+3        3.460211E+3        3.260914E+3        3.529040E+3

4082        10/1/2013 4:53:24 PM        2.024853E+3        1.965242E+3        2.337016E+3        2.346183E+3        2.346413E+3        2.074671E+3        2.523415E+3        2.420435E+3        2.123268E+3        2.261934E+3        1.974468E+3        3.086992E+3        2.918742E+3        3.120443E+3

4082        10/1/2013 4:56:58 PM        1.609547E+3        1.556852E+3        1.840109E+3        1.833377E+3        1.863864E+3        1.647335E+3        1.991165E+3        1.888984E+3        1.667032E+3        1.787104E+3        1.529102E+3        2.514233E+3        2.330850E+3        2.342409E+3

4082        10/1/2013 5:00:45 PM        1.147661E+3        1.079050E+3        1.257029E+3        1.252718E+3        1.294645E+3        1.171373E+3        1.370495E+3        1.288109E+3        1.145208E+3        1.240851E+3        1.067001E+3        1.759573E+3        1.644118E+3        1.587433E+3

4082        10/1/2013 5:06:46 PM        9.107603E+2        8.310951E+2        9.657699E+2        9.578681E+2        9.988612E+2        9.235483E+2        1.033463E+3        9.847561E+2        8.689996E+2        9.672294E+2        8.413191E+2        1.318447E+3        1.244057E+3        1.221025E+3

4082        10/1/2013 5:10:44 PM        7.755834E+2        7.109530E+2        8.218378E+2        8.168309E+2        8.471703E+2        7.848321E+2        8.770189E+2        8.301635E+2        7.366775E+2        8.308303E+2        7.115549E+2        1.104030E+3        1.042813E+3        1.043175E+3

4082        10/1/2013 5:13:15 PM        7.056554E+2        6.486815E+2        7.520301E+2        7.478205E+2        7.731759E+2        7.190693E+2        8.046789E+2        7.561894E+2        6.749289E+2        7.594802E+2        6.536049E+2        9.925164E+2        9.662078E+2        9.307597E+2

-----------------------

Re-tested board 5014 - This time channels 7 is OK, there is signal and no error counts. Optical power in channels 0,1 and 3 still lower than usual (1230, 680 and 1000 uW correspondingly). Optical inspection with the microscope didn’t find any dirt or dust around VCSELs.

========================================

09/30/2013

5000 - IVVDC = 379 mA, error counts test OK, optical powers are OK

5010 - IVVDC = 383 mA, error counts test OK, optical powers are OK

5016 - IVVDC = 379 mA, error counts test OK, optical powers are OK

5013 - IVVDC = 378 mA, error counts test OK, optical powers are OK

5008 - IVVDC = 380 mA, error counts test OK, optical powers OK (CH 2 a little low, ~1480)

5021 - IVVDC = 382 mA, error counts test OK, optical powers OK

5018 - IVVDC = 382 mA, error counts test OK, optical powers OK

5017 - IVVDC = 381 mA, error counts test OK, optical powers OK

5022 - IVVDC = 383 mA, error counts test OK, optical powers OK

5001 - IVVDC = 380 mA, error counts test OK, optical powers OK (CH 8 a little low ~ 1488)

5020 - IVVDC = 380 mA, error counts test OK, optical powers OK

5011 - IVVDC = 385 mA, error counts test OK, optical powers OK

5009 - IVVDC = 383 mA, error counts test OK, optical powers OK

5014 - IVVDC = 378 mA, optical powers bad in CH 0, 1, 3; VDC errors in CH 7 (no oscilloscope signal)

5012 - IVVDC = 380 mA, error counts test OK, optical powers OK

5019 - IVVDC = 382 mA, error counts test OK, optical powers OK

=========================================

09/19/2013

5033 - IVVDC = 380 mA, error counts test OK, optical powers are OK

5031 - IVVDC = 380 mA, error counts test OK, optical powers are OK

5027 - IVVDC = 382 mA, error counts test OK, optical powers are OK

5035 - IVVDC = 379 mA, error counts test OK, optical powers are OK

5041 - IVVDC = 385 mA, error counts test OK, optical powers are OK

5053 - IVVDC = 382 mA, error counts test OK, optical powers are OK

5051 - IVVDC = 381 mA, error counts test OK, optical powers are OK

5034 - IVVDC = 382 mA, error counts test OK, optical powers are OK

5036 - IVVDC = 382 mA, error counts test OK, optical powers are OK

5037 - IVVDC = 379 mA, error counts test OK, optical powers are OK

5044 - IVVDC = 358 mA, error counts test OK, optical powers are a little low

5052 - IVVDC = 382 mA, error counts test OK, optical powers are OK

5029 - IVVDC = 381 mA, error counts test OK, optical powers are OK

5039 - IVVDC = 383 mA, error counts test OK, optical powers are low in channels 10,11,12

5055 - IVVDC = 385 mA, error counts test OK, optical powers are OK

5046 - IVVDC = 386 mA, error counts test OK, optical powers are OK

5030 - IVVDC = 389 mA, error counts test OK, optical powers are OK

5047 - IVVDC = 381 mA, error counts test OK, optical powers are OK

6035 - IVVDC = 407 mA, error counts test is OK, optical powers are OK

6026 - IVVDC = 403 mA, error counts test is OK, optical powers are OK

=======================================

09/17/2013

5054 - IVVDC = 383 mA, error counts test is OK, optical powers are OK

=======================================

09/16/2013

Testing B-boards.

5024 - IVVDC = 367 mA, error counts test is OK, optical powers are OK

5042 - IVVDC = 382 mA, error counts test is OK, optical powers are OK

5028 - IVVDC = 375 mA, error counts test is OK, optical powers are OK

5043 - IVVDC = 382 mA, error counts test is OK, optical powers are OK

5050 - IVVDC = 382 mA, error counts test is OK, optical powers are OK

5049 - IVVDC = 387 mA, error counts test is OK, optical powers are OK

5045 - IVVDC = 380 mA, error counts test is OK, optical powers are OK

5025 - IVVDC = 385mA, error counts test is OK, optical powers are OK (2nd VCSEL is lower ~1500 uW)

5038 - IVVDC = 371 mA, error counts test is OK, optical powers are OK

4048- IVVDC = 383 mA, error counts test is OK, optical powers are OK

2 old IBLs:

6004 - 382 mA, error counts test is OK, optical powers are OK (a little lower, especially the second VCSEL, ~1500 uW)

6003 - 390 mA, error counts test is OK, optical powers are OK (the first VSCEL has lower optical power ~1200 uW)

1 old D-type board

4003 - 318 mA, VCSEL1 has sporadically disappearing signal. Optical power is zero for the VCSEL1 and low (~1100) for VCSEL2

4046 - 385 mA, error counts test is OK, optical powers are OK

====================================================

09/13/2013

Testing new optoboards

6033 - IVVDC = 405 mA, error counts test is OK, optical powers are OK

6039 - IVVDC = 408 mA, error counts test is OK, optical powers are OK

6037 - IVVDC = 407 mA, error counts test is OK, optical powers are OK

6040 - IVVDC = 412 mA, error counts test is OK, optical powers are OK

6036 - IVVDC = 402 mA, error counts test is OK, optical powers are OK

6045 - IVVDC = 407 mA, error counts test is OK, optical powers are OK

6031 - IVVDC = 403 mA, error counts test is OK, optical powers are OK

6012 - IVVDC = 416 mA, error counts test is OK, optical powers are OK

6018 - IVVDC = 400 mA, error counts test is OK, optical powers are OK

6011 - IVVDC = 415 mA, error counts test is OK, optical powers are OK

6007 - IVVDC = 406 mA, error counts test is OK, optical powers are OK

6023 - IVVDC = 412 mA, error counts test is OK, optical powers are OK

6017 - IVVDC = 400 mA, error counts test is OK, optical powers are OK

6019 - IVVDC = 401 mA, error counts test is OK, optical powers are OK

6008 - IVVDC = 412 mA, error counts test is OK, optical powers are OK

6025 - IVVDC = 409 mA, error counts test is OK, optical powers are OK

6020 - IVVDC = 407 mA ,error counts test is OK, optical powers are OK

6009 - IVVDC = 411 mA, error counts test is OK, optical powers are OK

6015 - IVVDC = 412 mA, error counts test is OK, optical powers are OK

6013 - IVVDC = 415 mA, error counts test is OK, optical powers are OK

6021 - IVVDC = 409 mA, error counts test is OK, optical powers are OK

6014 - IVVDC = 410 mA, error counts test is OK, optical powers are OK

6010 - IVVDC = 407 mA, error counts test is OK, optical powers are OK

======================================

09/12/2013

Testing new optoboards

6022 - IVVDC = 405 mA, error counts test is OK, optical powers are OK

6029 - IVVDC = 408 mA, error counts test is OK, optical powers are OK

6028 - IVVDC = 407 mA, error counts test is OK, optical powers are OK

6042 - IVVDC = 409 mA, error counts test is OK, optical powers are OK

6046 - IVVDC = 405 mA, error counts test is OK, optical powers are OK

6048 - IVVDC = 410 mA, error counts test is OK, optical powers are OK

6027 - IVVDC = 408 mA, error counts test is OK, optical powers are OK

6044 - IVVDC = 411 mA, error counts test is OK, optical powers are OK

6034 - IVVDC = 403 mA, error counts test is OK, optical powers are OK

6041 - IVVDC = 406 mA, error counts test is OK, optical powers are OK

6030 - IVVDC = 410 mA, error counts test is OK, optical powers are OK

6032 - IVVDC = 406 mA, error counts test is OK, optical powers are OK

6024 - IVVDC = 411 mA, error counts test is OK, optical powers are OK

6047 - IVVDC = 414 mA, error counts test is OK, optical powers are OK

============================================

09/10/2013

New patch from Jason is almost fine. There is no signal readout from channel 7 (both optical power and oscilloscope). Also, DORIC shows all data errors, I need to set “all 50%” to be able to set zero errors for all channels.

IBL test seems to be fine except DORIC test with Stop Errors: it’s not displayed.

09/05/2013

Optoboards used in nSQP test:

5023, 5003, 4032, 4064

Optobox Slots : 2, 4, 6, 9

08/08/2013

4 D and 4 B-boards will be used in nSQP test:

B-boards: 5020, 5003, 5004, 5015

D-boards: 4042, 4056, 4064, 4032. 4035

Replaced the old B-board B12005 with the new on 5003.

Turning off the power for all the optoboards. Running for ~25 hours without any problems.

============================================================

08/06/2013

A new set of optoboards to be connected to the optobox

4055, 4056, 4035, 4036, 4052, 4053, 4028, 4030

Re-tested 4051 with the new LabView code, using correct version of hep015a_nsqp_rev1.bit file. Now the software works fine. Checked this with the B--type board as well (5016) - works fine with this one too.

Tested a new optical cable, from the official production. Doesn’t seems to have any problems, mapping is correct.

Retesting 2 previously problematic optoboards

5010 - 386 mA, all channels no errors, optical power is OK

5013 - 376 mA, DORIC channel 6 has both Clk and Data errors, optical power is OK

 

Optoboard from the optobox had 20 mA Iset (at least was shown in DCS - not clear if the optoboard has received the full current), the optoboard is from Slot1, the edge of the optobox

4042 - 362 mA, errors ar ok, optical power is OK

An accident: while removing board number 4040 from the Slot6 of the optobox (very tight!), the connector of VCSEL1 got damaged. The board got accelerated and flight out from the box, falling on the floor. The optical fiber still can get into VCSEL connector, test shows no problem with the optical power or error counts for both DORIC and VCSELs.

======================================================

08/05/2013

Testing optoboard 4051 which was connected to Slot 11 of the optobox. This slot have received the inverted ISET polarity signal.

4051 - 362 mA, DORIC - all channels have Clk errors, channels 1,3 and 5 have a wrong signal shape (2 times shorter), channels 1,2,3,4,5,6 (all except channel 0) have Data error problem.  

VCSEL - channels 8 and 9 have VDC Data errors problem, despite the shape looks fine.

Optical power is OK.

Testing optoboard 4032 which was connected to Slot 4 of the optobox

4032 - 388 mA, DORIC - all channels have Clk errors, channel 1,3 and 5 have a wrong signal shape (2 times shorter), channels 1,2,3,4,5,6 (all except channel 0) have Data error problem. Optical power is Ok

For the reference, testing another D-board

4056 - 375 mA, has the same issues as the other tested channels. Definitely a problem with the software.

----------------------------------------------------------------------

Changed to the old version of LabView code.

4056 - is OK

4032 - 388 mA, DORIC channels 2 and 6 have Data error counts, despite the shapes look good and no error count signals are visible on the oscilloscope. VCSEL is good.

4051 - 354 mA, DORIC is OK, VCSEL is OK.

=============================================

07/30/2013

Using new VI patch  (CERN_nsqp_IBL_testbench)

5020 - VCSEL channels 11, 12 and 13 always have errors for all delays, they also have a wrong signal shape. Optical power is OK for all channels.

5016 - VCSEL channels 11, 12 and 13 always have errors for all delays, they also have a wrong signal shape. Optical power is OK for all channels.

5003 - VCSEL channels 11, 12 and 13 always have errors for all delays, they also have a wrong signal shape. Optical power is OK for all channels.

5009 - VCSEL channels 11, 12 and 13 always have errors for all delays, they also have a wrong signal shape. Optical power is OK for all channels.

-----------------------------------------------------------------------------------

Optoboards for the optobox test:

D-boards - 4064, 4060, 4051, 4047, 4039, 4044, 4037, 4040, 4032, 4032, 4062, 4042

=========================================================

07/27/2013 Testing new shipped boards

Moved the equipment from the radiation room to the clean room in SR1.

Checking one of the previously tested boards to make sure the equipment is working

4062 - 378mA, all channels no errors, optical power OK.

----------------------------------------

5018 - 381mA,  all channels no errors, optical power OK.

5022 - 379mA, all channels no errors, optical power OK.

2 observed issues with the b-boards:

1) On the B boards DORIC channel 5 and 7 have 100% correlated error counts.

2) When changing delay for VCSEL channel 8 or 9, the error counts in DORIC start going on (both click and data errors) for all DORIC channels. Opto reset doesn’t help.

4033 - 386mA, all channels no errors, optical power OK.

5020 - 379mA, all channels no errors, optical power OK.

5016 - 380mA, all channels no errors, optical power OK.

5017 - 382mA, all channels no errors, optical power OK.

5020 - 378mA, all channels no errors, optical power OK.

5023 - 379mA, all channels no errors, optical power OK.

4042 - 378mA, all channels no errors, optical power OK.

4042 - 370mA, all channels no errors, optical power OK.

5015 - 378mA, all channels no errors, optical power OK.

5021 - 386mA, all channels no errors, optical power OK.

5019 - 383mA, all channels no errors, optical power OK.

5014 - 379mA, all channels no errors, channel 1 and 3 have lower optical power (641 and 970 uW).

========================================================

07/15/2013 Testing new B-boards

----------------------------------------------------------------------------------

Previous D-board 4062, retested - 386mA, all channels no errors, optical power OK

5013 - 373mA, DORIC channel 6 shows strange signal and always counts error (both data errors for any delay value, and clk errors), optical power OK

5003 - 378mA, all channels no errors, optical power OK

5011 - 382mA, all channels no errors, optical power OK

5004 - 381mA, all channels no errors, optical power OK

5008 - 376mA, all channels no errors, optical power OK

5009 - 379mA, all channels no errors, optical power OK

5010 - 375mA, channel 9 VCEL has no signal (all three: oscilloscope, error counter and optical power).

5012 - 378mA, all channels no errors, optical power OK

==========================================================

07/06/2013 - retaking data for problematic boards

4039 - Optical power test seems to give a normal result (no asymmetry between two VCSELs)

4033 - the same optical power as tested yesterday (first 7 channels have lower power). VSEL2 connector got broken when I was disconnecting optical fiber... 2nd connector broken this way...

4055 - the same optical power test result as yesterday (first 7 channels have lower power). 

4053 - the same optical power test result as yesterday (first 7 channels have lower power).

4030 - the same optical power test result as yesterday (last 7 channels have lower power).

4062 - the same optical power test result as yesterday (channel 2 has a low optical power, ~860 uW)

5000 - The board is, probably, fine. There is a problem with the channel mapping (probably with the LabView macro -- or with the chip?). Channels for VCSEL2 are shifted by 2 when trying to set the correct delay for Stop Errors test. The response matrix is following:

   

    Channel where                 Channel which

   delay is changed           responds to the change

        10                                     8

        11                                     9

        12                                     10

        13                                     11

        14                                     12

        15                                     13

5001 - The same issue as for 5000: the channels for VCSEL2 are shifted by 2.

4034 - Completely normal board, no problems with channel 11, as it was yesterday.

===============================

07/05/2013 - new set of boards

ISET = 2mA for all boards

4033 - 391mA - all channels no errors, optical power is lower for the first 7 channels (channels 0-6, the power is ~1800-1900 uW)

4061 - 383mA, all channels no errors, optical power OK

4034 - 386mA, VDC channel 11 always has errors; optical power OK, except channel 11, where the power is 4811 uW.

4060 - 384mA, all channels no errors, optical power OK

4045 - 385mA, all channels no errors, optical power OK

4046 - 381mA, all channels no errors, optical power OK

4042 -  PIN connector is mechanically broken.

4044 - 382mA, all channels no errors, optical power OK

4055 - 351mA, all channels no errors, optical power is lower for the first 7 channels (channels 0-6, the power is ~1300-1500 uW)

4056 - 383mA, all channels no errors, optical power OK

4064 - 386mA, all channels no errors, optical power OK

4062 - 378mA, all channels no errors, optical power OK, except channel 2, where the power is 820 uW

4032 - 384mA, all channels no errors, optical power OK

4031 - 386mA, all channels no errors, optical power OK

4059 - 382mA, all channels no errors, optical power OK

4057 - 380mA, all channels no errors, optical power OK

4035 - 383mA, all channels no errors, optical power OK

4036 - 384mA, all channels no errors, optical power OK

4052 - 384mA, all channels no errors, optical power OK

4053 - 373mA, all channels no errors, optical power is lower for the first 7 channels (channels 0-6, the power is ~1500-1800 uW)

4051 - 358mA, all channels no errors, optical power OK

4047 - 374mA, all channels no errors, optical power OK

4030 - 380mA, all channels no errors, optical power is lower for the first 7 channels (channels 0-6, the power is ~1000-1500 uW)

4028 - 388mA, all channels no errors, optical power OK

4040 - 376mA, all channels no errors, optical power OK

4041 - 374mA, all channels no errors, optical power OK - VCSEL Input2 connector got broken when the optical cable was removed.

4039 - 357mA, all channels no errors, optical power is lower for the last 7 channels (channels 7-13, the power is ~1500-1800 uW)

4037 - 381mA, all channels no errors, optical power OK

5001 - 382mA, all channels no errors, optical power OK

5000 - 378mA, channel 11 of VDC is not stable (spontaneously start counting error for some time), channel 13 seems OK on the scope, but not possible to set a delay with 0 errors; optical power OK

=======================================

6/4/2013

ISET = 2mA for all boards

4006 - 377mA - all channels no errors, optical power OK

4005 - 311mA - all channels no errors, optical power OK, 2nd VCSEL lower power (~1100) IVDD LOW!

4024 - 408mA - all channels no errors, optical power OK

4022 - 388mA - all channels no errors, optical power OK

4013 - 382mA - all channels no errors, optical power OK

4014 - 389mA - all channels no errors, optical power OK

4017 - 377mA - all channels no errors, optical power OK

4018 - 384mA - all channels no errors, optical power OK

4007 - 357mA - all channels no errors, optical power OK

4008 - 359mA - all channels no errors, optical power OK

4009 - 361mA - all channels no errors, optical power OK

4019 - 392mA - all channels no errors, optical power OK

4015 - 378mA - all channels no errors, optical power OK

4016 - 401mA - all channels no errors, optical power OK

4027 - 380mA - all channels no errors, optical power OK

4011 - 382mA - all channels no errors, optical power OK

4012 - 382mA - all channels no errors, optical power OK